This is a highly accurate microprocessor-controlled pressure measuring instrument.SensoBrain > TM , a KELLER-designed low power signal processor, transmits the signals of thepressure- and temperature sensor to the microprocessor, which digitally compensates the sensor data. This mathematical modelling of the pressure sensor virtually eliminates all errors over a wide temperature range. M > ANO G > AUGE (Basic Version)Display of:Pressure, Pressure Unit, Temperature, Elapsed TimeAlternative:Pressure, Pressure Unit, Max.- and Min. ValueAll functions are executed with the front key of the instrument. It allows the display to be set tozero and to change the measuring cycle for prolonged battery life. M > ANO R > ECORD (M > ANO G > AUGE plus data recording)Based on the M > ANO G > AUGE ,the M > ANO R > ECORD records and stores the measured values. Thefront key is used to select which data shall be displayed and stored, and to set the recording interval and the number of readings (memory for 900). The read-out of the stored data to a PC is via RS 232 serial interface (Logger Software and K101 cable available as option). The data transfer takes place via the serial interface on the PC and must not be done inintrinsic area! > KELLER KELLER Front KeyButton 80 mm 80 mm HEX 27G 1/4"HEX 19G 1/4" 76 mm Series 11 Transducer(up to 1000 bar)Series 6 Transducer(up 600 bar) Subject to alterations KELLER AG fr Druckmesstechnik St. Gallerstrasse 119CH-8404 WinterthurTel. 052 - 235 25 25Fax 052 - 235 25 00 KELLER Gesellschaft f輼r Druckmesstechnik mbH Schwarzwaldstrasse 17D-79798 JestettenTel. 07745 - 9214 - 0Fax 07745 - 9214 - 50 Companies approved to ISO 9001 / EN 290013/02 www.keller-druck.com size="-4">

 Open the catalog to page 1

Sealed Gauge or Absolute > ECORD Vented Gauge or Absolute > In M ANO G AUGE and M ANO R ECORD the measuring ranges aredivided by 12 bit or 3000 points.The resolution is determined by the measuring range and thenumber of measuring points. All instruments can be supplied with 8 bit, 10 bit or 12 bitresolution. Range Resolution Resolution 1000 mbar0,3 mbar-12 bar1 mbar 10 bar3 mbar 30 bar10 mbar 100 bar0,03 bar300 bar0,1 bar 600 bar0,2 bar 1000 bar0,3 bar ŕ Specific Characteristics Environmental Characteristics Total Accuracy > (1) Operating TemperatureհC- 1060 Compensated Range Range...

 Open the catalog to page 2

All KELLER catalogs and technical brochures

  1. KELLER

    36 Pages

  2. Series 26 Y

    2 Pages

  3. Series 26 W

    1 Pages

  4. Handpump K/P

    1 Pages

  5. K-114 BT

    3 Pages

  6. K-114

    3 Pages

  7. 21 ge

    1 Pages

  8. LEO 3

    1 Pages

  9. FA-23

    1 Pages

  10. Series 8

    2 Pages