Introduction
The document discusses the challenges and solutions for non-contact temperature measurement of metal sheets at low temperatures, focusing on the use of pyrometers.

Specifications
For measuring metal sheets starting at room temperature, long-wave pyrometers with a spectral sensitivity of 8-14 µm are recommended. However, for temperatures starting at 75 °C, shortwave devices with a wavelength of approximately 2.4 µm are preferred due to their higher sensitivity and reduced pollution sensitivity.

Challenges
1. Low thermal radiation and special radiation properties of metals make measurement challenging.
2. Longwave pyrometers capture more reflecting radiation than the actual sheet temperature.
3. Shortwave pyrometers are sensitive to interfering radiation from artificial light or sunlight, especially below 150 °C.

Solutions
1. Use shadowing measures to protect against extraneous light for temperatures up to 150 °C.
2. In coil gaps, multiple reflections improve emissivity, allowing better temperature measurement.
3. Use pyrometers with high optical resolution and laser sighting for accurate measurement in coil gaps.

Measurement Systems
Two pyrometer models are discussed:
  • PA 10 AF 1/L: Measuring range 0-1000 °C, spectral range 8-14 µm.
  • PA 28 AF 10/L: Measuring range 75-650 °C, spectral range 1.8-2.4 µm.
Both models have specific response times and require a 24 V DC power supply.

Mounting Assemblies
Two mounting assemblies are detailed, each consisting of components like dust stops, cooling jackets, and oscillating mirrors to ensure optimal measurement conditions.

Contact Information
Contact details for Keller HCW GmbH and its international sales and service centers in China, France, India, and Russia are provided.
See more

Catalog excerpts

AN Metal sheets_201608_en-1

INFRARED THERMOMETER SOLUTIONS Metal Sheets Temperature measurement of bright metal

 Open the catalog to page 1
AN Metal sheets_201608_en-2

Application note Metal Sheets Non-contact temperature measurement of metal sheets strong thermal radiation. This also eliminates the influence of reflecting Interfering radiation. The measurement of metal sheets at low temperatures is still a challenging measuring task in the field of non-contact measurements due to the very low thermal radiation and the special radiation properties of metals. For physical reasons only longwave pyrometers with a spectral sensitivity of 8 - 14 µm can be used for measurements starting at room temperature. However, the emissivity of metals, i.e. the ability to emit...

 Open the catalog to page 2
AN Metal sheets_201608_en-3

The correlations are as follows: • The larger the coil, the narrower is the formed gap. • The narrower the gap, the higher is the number of reflections. • The higher the number of reflections, the higher is the artificial increase of the emissivity. • The higher the emissivity, the higher is the temperature signal received by the pyrometer. This signal peak is detected by the peak picker which is integrated into the pyrometer. The measurement interval of the peak picker is selected according to the set swivel period. As a result, the varying signal becomes a continuous temperature value. Sheet...

 Open the catalog to page 3
AN Metal sheets_201608_en-4

INFRARED THERMOMETER SOLUTIONS I Sales and Service Center Sales abroad Keller HCW GmbH • Division MSR Sales and Service Center

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.