1. Catalogs
  2. Keithley Instruments
  3. Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies
video corpo

Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies
1 /13Pages

Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies

Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies
1 /13Pages

Catalog excerpts

Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies-1

Key Features • Monitor load currents from 100 nA to 6 A with high accuracy • Measure voltage and current with 6'/2-digit resolution • Capture dynamic load currents as short as 140 |_is • Output up to 192 W of low noise, linear regulated power • Programmable rise and fall times eliminate voltage overshoot and undershoot transients • Built-in graphing simplifies analyzing trends or displaying voltage or current waveforms • High resolution TFT display and soft-key/icon-based user interface simplify power supply operation • Programmable output sequences reduce test times • Sink up to 0.45 A to discharge voltage quickly • Digital I/O for direct communication with other devices and instruments • Built-in web page simplifies automated control/ monitoring • Automate tests easily with KickStart startup software The Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies are much more than just sources of clean power; they are also precision measurement instruments. They can source stable, low noise voltages as well as monitor load currents over a wide dynamic range from amps to nanoamps. Both supplies use linear regulation to ensure low output noise and superior load current measurement sensitivity. A high resolution color Thin Film Transistor (TFT) screen displays a wide range of information on measurements. Soft-key buttons and a navigation wheel combine with the TFT display to provide an easy-to-navigate user interface that speeds instrument setup and operation. In addition, built-in plotting functions allow monitoring trends such as drift. These supplies provide the flexibility required for both benchtop and automated test system applications. For example, they provide a list mode, triggers, and other speed optimization functions to minimize test time in automated testing applications. DMM-Ouality Low Current Measurements with High Resolution Unlike conventional power supplies, Series 2280S supplies can also make measurements with up to 6/ digits of resolution. Voltage output measurements can be resolved down to 100 pV. These supplies measure load currents from 100 nA to amps and can resolve down to 10 nA. Four load current measurement ranges (10 A, 1 A, 100 mA, and 10 mA) support measuring a device's full load current, standby mode current, and small sleep mode currents with DMM-quality accuracy. The high resolution allows characterizing small changes in load currents with confidence. It also makes it possible to make a broad range of measurements on a single range with excellent accuracy across both low and high current values.

 Open the catalog to page 1
Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies-2

Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies Measure Rapidly Changing Loads To monitor fast-changing and pulse-like load currents properly, Series 2280S supplies offer the speed necessary to capture load changes that occur at intervals as short as 140 µs. This capability allows designers and manufacturers of portable, battery-operated devices to monitor load currents easily in all of a device’s operating modes so they can determine the device’s total power consumption. This high speed measurement capability allows measuring each state of a power-up load sequence...

 Open the catalog to page 2
Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies-3

Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies View and Control Every Parameter of the Supply for Maximum Performance The bright, 4.3-inch TFT display shows voltage and current readings, the source settings and many additional settings in large, easy-to-read characters. The icon-based main menu provides all the functions users can control and program for fast access to source setup, measurement setup, display formats, trigger options, and system settings. Menus are short, and the menu options you need are easy to find and clearly described, so that you can set up...

 Open the catalog to page 3
Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies-4

Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies Controlled Rise and Fall Times Protect Devices Under Test Perform Semi-Automated Testing Right on Your Bench Are you working on a device or a system with a high in-rush current? Series 2280S supplies allow programming the voltage output’s rise time to slow the voltage ramp and avoid voltage overshoot, which could potentially damage the DUT. The voltage fall time can also be controlled to prevent a fast ramp down of the output voltage. Voltage rise and fall times can be set as slow as 10 V/s or as fast as 100 V/s. Small...

 Open the catalog to page 4
Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies-5

Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies Trend Analysis and Load Current Characterization Automate a test quickly and easily with KickStart software Use the built-in graphing function to monitor the stability of the load current or capture and display a dynamic load current. Or, use it to view a start-up or turn-off load current. Series 2280S supplies can take measurements quickly and store up to 2,500 measurement points. In addition to displaying a voltage or current waveform or both, they can compute statistics on the stored data. Statistical calculation...

 Open the catalog to page 5
Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies-6

Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies Optimized Performance for Production Test Series 2280S supplies are as powerful in a production test system as they are flexible on the R&D benchtop. In addition to their List Mode function, several other Series 2280S features help minimize test time in automated systems. For example, an external trigger input allows hardware synchronization and control by other instruments in the test system. To eliminate many system delays, Series 2280S supplies produce a “measurement c omplete output” to signal the test system when...

 Open the catalog to page 6
Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies-7

Series 2280S Precision Measurement, Low Noise, Programmable DC Power Supplies 23 °C ±5 °C with 1-hour instrument warm-up. Load Transient Recovery Time Resistive load change 50% load to 100% load or 100% load to 50% load: <50 ps to within 15 mV of V-set. Slew Rate: Rising Voltage and Falling Voltage 10 V/s to 100 V/s. Up to 1000 V/s under limited conditions3. 100 V/s (default). Maximum Source Voltage Drop per Lead To maintain specified voltage accuracy: 1 V. Maximum Sense HI and Sense LO Lead Resistance To maintain specified voltage accuracy: 2 Q. 1 Specifications based on using remote sense connections....

 Open the catalog to page 7

Archived catalogs

  1. 6 Series B MSO

    69  Pages

  2. 3 Series MDO

    36  Pages

  3. 4 Series MSO

    40  Pages

  4. TSG4100A Series

    24  Pages

  5. RTPA2A

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.