Catalog excerpts
Integra Series systems (2700, 2701, 2750) combine precision measurement, switching, and c ontrol in a single, tightly integrated enclosure for either rack-mounted or benchtop applications. These cost-effective, high performance test platforms offer affordable alternatives to separate DMMs and switch systems, dataloggers/ recorders, plug-in card data acquisition equipment, and VXI/PXI systems. The Integra Series plug-in switching and control modules offer unmatched flexibility and testing efficiency for a wide range of industries and applications. System builders can create test solutions with a combination of channel count, cost per channel, and system performance unmatched by any other single-box measurement system. The input modules provide the flexibility to vary the channel count from 20 to 200 (2-pole), apply a stimulus to the device under test, route signals, control system components, and make precision measurements with up to 14 functions. Robust d igital I/O capabilities can be used for triggering, handshaking with other automation equipment, and alarm limit outputs. Scan rates of up to 500 channels/second (up to 3500 readings/second on p a single channel) will increase test roductivity. • Combines functions of DMM, switch system, and datalogger • True 6½-digit (22-bit) resolution • Choice of 12 switch/control plug-in modules • Up to 200 differential input channels (with 300V isolation) for measurement and control • Convenient front panel inputs • Free LabVIEW®, LabWindows/ CVI, Visual Basic, and C/C++ drivers (IVI style) DIGITAL MULTIMETERS & SYSTEMS Multimeter/Data Acquisition/ Switch Systems • Ethernet, GPIB, RS-232 communications capabilities • Free ExceLINX ™-1A datalogging software Fast Setup and Operation The Integra systems are fully integrated, off-the-shelf measurement and control systems. Their DMMlike interfaces make it easy for users to collect data and/or perform troubleshooting within minutes of installation and startup. Once sensor or DUT leads are hooked to the instrument’s input, use the front panel controls to select the measurement function, range, filtering, scaling, trigger source, scanning sequence, alarms, and more. The free ExceLINX-1A software makes it easy to configure and use the system in a graphical “point-and-click” environment. This gives developers the basic tools needed to create a simple application without writing program code. The Advantage of Integrated Design The Integra systems offer a variety of advantages over existing solutions for ATE and data acquisition applications. For example, their flexible modular architecture and integrated measurement, switching, and control capabilities save rack space by reducing the number of separate instruments needed. This design also simplifies expanding the system as the number of channels grows or re-purposing it as new test requirements evolve. Integrated signal conditioning, scaling, stimulus, filtering and I/O capabilities eliminate the need for external circuitry when designing and building data acquisition systems. The Integra systems offer Built-in measurement functions accuracy and repeatability superior to plug-in include: data acquisition boards, while providing faster • DCV • ACV • DCI • ACI test times than typical DMM/switch systems. This • Resistance (2- or 4-wire, offset makes it possible to combine higher test yields compensation selectable) with higher test throughput. Ethernet The Model 2701 offers a 10/100 BaseT Ethernet connection for high speed and long distance communication between a computer and a virtually infinite number of instruments. Any PC with an Ethernet port can connect to a single Model • Dry circuit ohms (20mV clamp) 2750 only • Temperature (with thermo couples, RTDs, or thermistors) • Frequency/Period • Continuity 1.888.KEITHLEY (U.S. only) www.keithley.com A Greater Measure of Confidence Integra Series integrated switching, measurement, and datalogging solutions Integra Series integrated switching, measurement, and datalogging solutions
Open the catalog to page 1DMM, Data Acquisition, Datalogging System w/2 Slots DMM, Data Acquisition, Datalogging System w/2 Slots and Ethernet Support DMM, Data Acquisition, Switching, Datalogging System w/5 Slots Accessories Supplied LabVIEW, LabWindows/ CVI, Visual Basic, and C/C++ drivers; manual; and Model 1751 Safety Test Leads. 2701 in a point-to-point configuration, to multiple Model 2701s through a hub, or to multiple Model 2701s distributed on a network. The Model 2701 Ethernet port uses the industry-standard TCP/IP socket interface. This provides data rates up 100Mbits/sec. and allows the instrument to be...
Open the catalog to page 2Immediate alarm notification provided by built-in open- collector digital I/O lines for control, external triggering, with TCP/IP protocol and control modules makes change input signals or control Built-in relay cycle diagnostic tool (2701 only) • Send command strings To start communicating with the Integra Series instrument, simply port using the supplied RJ-45 cross- over cable, start Microsoft® Internet Explorer version 5.0 or later, and type the instrument's IP address into the URL line. The built-in web diagnostic interface allows for easy without the need to install external software....
Open the catalog to page 3Ordering Information 7700 20-channel Differential Multiplexer Module with up to 50MHz Bandwidth, Automatic CJC, and Screw Terminals 7701 32-channel Differential Multiplexer Module with a 25- and 50-Pin Female D-Sub Connector. Supplied with Male IDC Ribbon Cable Connectors 7702 40-channel Differential Multiplexer Module w/ Screw Terminals 7703 32-channel, High Speed, Differential Multiplexer Module with 2 50-Pin Female D-Sub Connectors. Includes 2 Mating Connectors 7705 40-channel, Single-pole Control Module with 2 50-Pin Female D-Sub Connectors. Includes 2 Mating Connectors 7706 All-in-One...
Open the catalog to page 4All Keithley Instruments catalogs and technical brochures
-
6220-6221
5 Pages
-
6482
3 Pages
-
2520
8 Pages
-
2606B
13 Pages
-
2601B
20 Pages
-
AFG1000 Series
13 Pages
-
AFG31000 Series Datasheet
22 Pages
-
2182A Nanovoltmeter
6 Pages
-
6 Series B MSO
69 Pages
-
Isolated Measurement Systems
8 Pages
-
TBS1000B-EDU Series
14 Pages
-
3 Series MDO
36 Pages
-
4 Series MSO
40 Pages
-
TSG4100A Series
24 Pages
-
2461-EC Graphical Potentiostat
16 Pages
-
2460-EC Graphical Potentiostats
15 Pages
-
2450-EC Graphical Potentiostat
15 Pages
-
4200A-SCS Parameter Analyzer
45 Pages
-
MDO4000C Series Datasheet
43 Pages
-
RTPA2A
6 Pages
-
TPA-N-PRE Datasheet
4 Pages
-
DPO4PWR·MDO3PWR Datasheet
6 Pages
-
DPO4LMT/MDO3LMT Datasheet
6 Pages
-
DPO7000 Series Datasheet
28 Pages
-
SourceXpress® Datasheet
4 Pages
-
10G-KR Datasheet
8 Pages
-
DPO70000SX Series Datasheet
46 Pages
-
AWG4000 Series Datasheet
20 Pages
-
TLA6400 Series Datasheet
14 Pages
-
Potentiostats 2450-EC
8 Pages
-
4200-SCS
16 Pages
-
2013 Keithley product catalog
403 Pages
-
Nanotechnology Measurement
13 Pages
-
Semiconductor Device Test
11 Pages
-
Series 2400 SourceMeter®Family
16 Pages
Archived catalogs
-
8 Series Sampling Oscilloscope
14 Pages
-
Multimeter/Switch System
1 Pages