Isolated Measurement Systems - 1

The Tektronix TIVM and TIVH Series IsoVu™ Measurement Systems offer galvanically isolated measurement solutions for accurately resolving high bandwidth, differential signals up to ±2500 V in the presence of large common mode voltages with the best in class common mode rejection performance across its bandwidth. Applications Half/Full Bridge designs using GaN, SiC, IGBTs Floating measurements Power Converter design Power Device evaluation Switching Power Supply design Inverter design Motor Drive design Electronic Ballast design EMI ESD Current shunt measurements Remote probing capability Product Description The TIVM and TIVH Series (IsoVu) products can be used on most Tektronix oscilloscopes with the TekVPI interface and on MSO/DPO70K series oscilloscopes with the TCA-VPI50 adapter. IsoVu utilizes an electrooptic sensor that converts the electrical signal from the sensor tip cables to an optical signal, which electrically isolates the device-under-test from the oscilloscope. IsoVu incorporates four separate lasers, an optical sensor, five optical fibers, and sophisticated feedback and control techniques. The sensor head, which connects to the test point, has complete electrical isolation and is powered over one of the optical fibers (No batteries required). IsoVu is an ideal solution for users making the following measurements: Features and benefits • Bandwidths from DC to 1 GHz • 100 Million to 1 (160 dB) Common Mode Rejection from DC up to 1 MHz 10,000 to 1 (80 dB) Common Mode Rejection at 1 GHz 60 kV peak Common Mode Voltage Up to ±2500 V Differential (DC + pk AC) Up to ±2500 V offset range Output clamping Safety certified DC and AC input coupling • Differential measurements in the following conditions: Complete galvanic isolation is required High common mode voltage High frequency common mode interference High frequency measurements • Measurements in high EMI environments • EMI compliance testing • ESD testing

Open the catalog to page 1
Isolated Measurement Systems - 2

All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise. TIVM Series attenuation, Differential input voltage range, Offset range, Differential impedance (Typical) TIVH Series attenuation, Differential input voltage range, Offset range, Differential impedance (Typical) 1 The 800 MHz bandwidth is achieved with the 50X and greater attenuation tips (MMCX50X, MMCX250X, SQPIN100X, SQPIN500X, WSQPIN1000X, or WSQPIN2500X). 2 With 6-inch tip cable sensor head 20 pF plus cable 15 pF.

Open the catalog to page 2
Isolated Measurement Systems - 3

TIVM Series Common mode rejection ratio, sensor tip cables, and adapters (Typical) TIVM Series Maximum nondestructive voltage (Typical)

Open the catalog to page 3
Isolated Measurement Systems - 4

System noise (input referred) (Typical) Propagation delay 3 meter fiber cable 35 ns ±5 ns 10 meter fiber cable 68 ns ±7 ns Laser certification CLASS I LASER PRODUCT This product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007. 3 Derated with frequency; refer to the Maximum differential input voltage vs. frequency derating graph in the Specifications section of the TIVH Series IsoVu Measurement System User Manual. 4 The capacitance between the sensor head and a reference plane. The sensor head is placed six inches (15.25 cm)...

Open the catalog to page 4
Isolated Measurement Systems - 5

Isolated Measurement Systems

Open the catalog to page 5
Isolated Measurement Systems - 7

Isolated Measurement Systems The measurement systems can be used with the following Tektronix oscilloscopes. For oscilloscopes not included in this list, contact your local Tektronix representative. • 5 Series MSO (WSQPIN2500X tip cables require V1.6 or later oscilloscope firmware) • MDO3000 series (WSQPIN tip cables require V1.26 or later oscilloscope firmware) • MDO4000C series (WSQPIN tip cables require V1.06 or later oscilloscope firmware) • MSO/DPO/MDO4000B series (WSQPIN tip cables are not compatible) • MSO/DPO5000B series • DPO7000C series In addition to the above oscilloscopes, the...

Open the catalog to page 7
Isolated Measurement Systems - 8

* European toll-free number. If not accessible, call: +41 52 675 3777 For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tek.com. Copyright ® Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK...

Open the catalog to page 8

All Keithley Instruments catalogs and technical brochures

  1. 6220-6221

    5 Pages

  2. 6482

    3 Pages

  3. 2520

    8 Pages

  4. 2606B

    13 Pages

  5. 2601B

    20 Pages

  6. AFG1000 Series

    13 Pages

  7. 6 Series B MSO

    69 Pages

  8. 3 Series MDO

    36 Pages

  9. 4 Series MSO

    40 Pages

  10. RTPA2A

    6 Pages

  11. 4200-SCS

    16 Pages

Archived catalogs