Catalog excerpts
Scalable Performance Oscilloscopes DPO70000SX Series Datasheet DPO70000SX provides ultra-high bandwidth real time signal acquisition and analysis up to 70 GHz analog bandwidth. The patented Asynchronous Time Interleaving (ATI) architecture provides the lowest noise and highest fidelity for real time signal acquisition. Superior signal fidelity and excellent signal-to-noise ratio Stable and precise multi-channel timing for most accurate analysis Compact instrument package with flexibility for future expansion and simple reconfiguration Introduction DPO70000SX Series oscilloscopes provide the most accurate real time performance for ultra-bandwidth applications. Precise, scalable performance using UltraSync multi-unit time synchronization bus Highest trigger performance with >25 GHz Edge trigger bandwidth, unique Envelope trigger Low-noise, high fidelity signal acquisition is critical in ultra-bandwidth applications such as long-haul coherent optical, 400G datacom and wideband RF. The flagship DPO77002SX model uses ATI (Asynchronous Time Interleaving) architecture to achieve 70 GHz and 200 GS/s (5 ps/ Sample) real time acquisition performance. This patented, symmetric architecture elegantly creates an inherent noise advantage over legacy bandwidth interleaving methods. The DPO70000SX provides the lowest noise, highest fidelity and maximum performance for complex optical modulation analysis, jitter and noise analysis of high speed serial signaling and frequency, phase and modulation analysis of wideband RF signals. Low noise, 70 GHz real time signal capture using patented ATI architecture Compact 5 ¼" (3U) instrument package for the most versatile multichannel systems
Open the catalog to page 1• 200 GS/s, 5 ps/Sample real-time sample rate DPO70000SX Digital Phosphor Oscilloscopes • 100 GS/s, 10 ps/Sample real-time sample rate
Open the catalog to page 2Scalable Performance Oscilloscopes • Coherent optical modulation analysis • Research and defense data acquisition and analysis • 100G/400G datacom system debug • PCIe debugging and compliance testing
Open the catalog to page 3Datasheet ATI architecture delivers lowest noise Previous real time scope solutions for digitizing ultra-high bandwidth signals distribute signal energy to two digitizing paths then use DSP to reconstruct the input signal. Unlike legacy schemes, Tektronix' unique ATI architecture provides a symmetric technique that delivers all signal energy to both digitizing paths resulting in an inherent noise advantage. The diagram shows how an input signal enters the ATI ASIC where it is sampled and alternately delivered to each digitizing subsystem. The sample clock runs at 75 GHz and effectively...
Open the catalog to page 4Scalable Performance Oscilloscopes Compact ultra-performance oscilloscope DPO70000SX Series models establish a unique compact oscilloscope package that enables unprecedented workspace efficiency and mounting versatility. The SX series provides a differentiated approach to ultrabandwidth real time acquisition that aligns with user trends toward large external monitors, higher degrees of automation and increased separation of data collection and data analysis workspaces. Stand-alone DPO70000SX compact models provide functionality equivalent to their bench counterparts (DPO70000DX) at half the...
Open the catalog to page 5Remote desktop operation As with current bench-model DPO /MSO70000 Series instruments, DPO70000SX models can be operated remotely over a network using Windows® Remote Desktop. Use the Windows Remote Desktop utility to access your oscilloscope from across the lab or across the globe. Precision synchronization for multi-unit systems DPO70000SX Series instruments include the Tektronix UltraSync multi-unit time synchronization bus. UltraSync is used to synchronize sample clock, trigger and run-stop control across multiple units with performance equivalent to that found in monolithic scopes....
Open the catalog to page 6Scalable Performance Oscilloscopes This scalable approach to performance allows users to purchase performance suitable for today's requirements, such as four channels of 33 GHz, 100 GS/s acquisition while also having two channels with 70 GHz, 200 GS/s performance suitable for next-generation designs. Subsequently, two additional units can be added for a total of four channels at 70 GHz, 200 GS/s. Units in this four-unit configuration can be separately deployed as pairs or standalone units at any time to meet other test demands. Another important aspect of skew is how the phase relationship...
Open the catalog to page 7Datasheet Applications Datacom standards Recommended bandwidth Tektronix scope model PAM4 and NRZ measurements – As datacom networks increase their throughput, the DPO70000SX is ready to perform standards validation for many of today's 25/28 G industry standards (see chart below). With 50 GHz and 70 GHz models featuring the low-noise ATI architecture; the DPO70000SX, combined with DPOJET Jitter & Noise Analysis and the SDLA Serial Data Link Analysis tools, can perform accurate de-embedding and eye diagram evaluation on many of these key standards. Datacom measurements PCI Express®...
Open the catalog to page 8Scalable Performance Oscilloscopes Ethernet Compliance Test Solution (Option ET3) - Receive full PHY layer support for Ethernet variants 10BASE-T, 100BASE-TX, and 1000BASE-T with the comprehensive, integrated Tektronix® Ethernet tool set. Analog verification, automated compliance software, and device characterization solutions are all included
Open the catalog to page 9TMiEjtpriitEil»rn«TK - (Unililidr Ethernet Transmitter Test Application (Option XGBT2 and NBASET) - Automates 10GBASE-T, NBASE-T, and IEEE802.3bz (2.5G/5G) physical medium attachment (PMA) and physical-layer (PHY) electrical testing to provide a fast and accurate way of testing your Ethernet designs. TekEspresslOG KRlEualuation Version] - (Untitled)' wjiviflnriii Mirj VIEHN Compliance * NumhEf of Lanes ro Test 10GBASE-KR/KR4 Compliance and Debug Solution (Option 10G-KR) - Automated compliance measurements for IEEE 802.3ap-2007 specifications. This option includes an automated compliance...
Open the catalog to page 10All Keithley Instruments catalogs and technical brochures
-
6220-6221
5 Pages
-
6482
3 Pages
-
2520
8 Pages
-
2606B
13 Pages
-
2601B
20 Pages
-
AFG1000 Series
13 Pages
-
AFG31000 Series Datasheet
22 Pages
-
2182A Nanovoltmeter
6 Pages
-
6 Series B MSO
69 Pages
-
Isolated Measurement Systems
8 Pages
-
TBS1000B-EDU Series
14 Pages
-
3 Series MDO
36 Pages
-
4 Series MSO
40 Pages
-
TSG4100A Series
24 Pages
-
2461-EC Graphical Potentiostat
16 Pages
-
2460-EC Graphical Potentiostats
15 Pages
-
2450-EC Graphical Potentiostat
15 Pages
-
4200A-SCS Parameter Analyzer
45 Pages
-
MDO4000C Series Datasheet
43 Pages
-
RTPA2A
6 Pages
-
TPA-N-PRE Datasheet
4 Pages
-
DPO4PWR·MDO3PWR Datasheet
6 Pages
-
DPO4LMT/MDO3LMT Datasheet
6 Pages
-
DPO7000 Series Datasheet
28 Pages
-
SourceXpress® Datasheet
4 Pages
-
10G-KR Datasheet
8 Pages
-
AWG4000 Series Datasheet
20 Pages
-
TLA6400 Series Datasheet
14 Pages
-
Potentiostats 2450-EC
8 Pages
-
4200-SCS
16 Pages
-
2013 Keithley product catalog
403 Pages
-
Nanotechnology Measurement
13 Pages
-
Semiconductor Device Test
11 Pages
-
Series 2400 SourceMeter®Family
16 Pages
Archived catalogs
-
8 Series Sampling Oscilloscope
14 Pages
-
Multimeter/Switch System
1 Pages