The DAQ6510 is a precision data acquisition and logging system that creates a new level of simplicity compared with the often complicated configuration and control found in many standalone solutions. A large 5-inch (12.7 cm) multi-touch display will guide users through set-up, data visualization, and analysis, removing the necessity of a PC and custom software for many applications. If you prefer or require a PC, a complement of IVI and Labview drivers and the Keithley KickStart Instrument Control Software are available to help with any application. Using Keithley's newest 6'/2-digit multimeter technology, you will find even greater accuracy, functionality, and speed. Two-year accuracy specifications are included, so you can be assured your critical measurements remain accurate and fully traceable. • Large, 5-inch (12.7 cm) multi-touch capacitive touchscreen with graphical display • 2-year specified, full featured, traceable 6^-digit multimeter with 0.0025% DCV (1 V, 10 V ranges) basic accuracy • Standard LAN/LXI and USB-TMC communication interfaces • Optional interfaces include GPIB, RS-232, and TSP-Link® Technology • 10 different switch and control modules to connect to as many as 80 DUTs in one test set-up • Up to 80 2-pole channels of thermocouple, RTD, or thermistor temperature measurements • Scanning speeds as high as 800 channels/second with the solid state relay module • Front panel jacks for stand-alone DMM operation • KickStart easy-to-use control software with a data acquisition and logging application • Three-year warranty Build a test sequence and define the required measurements from one setup screen. First, select the channels that will be used. Next, assign a measurement With 12 plug-in switching and control modules available and two module slots, you can build a test system that can measure or control up to 80 devices-under-test (DUTs) in a multiplexing configuration. With two 6*8 matrix modules, a total of 96 crosspoints, the DAQ6510 can test one or multiple ICs. For high volume production testing, select a solid state multiplexer module to maximize throughput with 800 channels/s scanning speed and minimize downtime compared with fixed life, electro-mechanical relays. A number of modules have cold junction compensation, temperature references for thermocouple temperature monitoring of devices during environmental testing, and HALT and HASS accelerated life testing. Even switch signals from wireless devices with RF modules having a maximum switching frequency of 3.5 GHz.
Open the catalog to page 1DAQ6510 Data Acquisition and Logging, Multimeter System function to a channel or a group of channels. Then define both the time interval between measurements and scans if multiple scans are required. That is the minimum set of parameters needed to run a test. There are additional optional parameters to adjust the measurements and the switching to meet a specific application. One option eases the identification of channels by allowing the creation of a name for each channel. Do all this from two menus and see – on one screen – how each channel is configured. The touchscreen, graphic display shows...
Open the catalog to page 2DAQ6510 Data Acquisition and Logging, Multimeter System 5-inch (12.7 cm) touchscreen allows One button access access to more setup, monitoring, and for easier navigation analysis data Apps key for quick access to customized programs Online HELP is just a button press away Store test results— and screen images quickly via the USB 2.0 Host Port DAQ6510 DATA ACQUISITION / MULTIMETER SYSTEM Front panel inputs allow you to use the DAQ6510 as a digital multimeter Lower swipe screen speeds up access Front/rear input selector pushbutton to often-used features such as function with LED to easily identify...
Open the catalog to page 3DAQ6510 Data Acquisition and Logging, Multimeter System Test a Wide Range of Devices and Components with 6½-digit DMM High Performance Measurements Make your measurements with instrument-grade quality. The DAQ6510 is a fully-featured 6½-digit DMM. The chart below shows all of the DAQ6510’s 15 measurement functions and ranges. All these measurement functions can be used with the various plug-in switch modules. Furthermore, a channel can be programmed for enhanced measurement features to address requirements for tighter tolerance or higher speed. For maximum accuracy, measurements can be filtered...
Open the catalog to page 4DAQ6510 Data Acquisition and Logging, Multimeter System Monitor Any Temperature Range and Select Optimal Accuracy Using a Wide Range of Temperature Sensors The DAQ6510 can process signals from any of eight thermocouple types to test over an extreme range of temperatures, –200°C to 1820°C. For more accurate temperature readings over a more narrow temperature range, the DAQ6510 can measure temperature from –80°C to 150°C with a 2-year accuracy of 0.08°C using 2.5 kΩ, 5 kΩ, and 10 kΩ thermistors. Alternatively, the DAQ6510 can measure temperature between –200°C and 850°C using resistance temperature...
Open the catalog to page 5DAQ6510 Data Acquisition and Logging, Multimeter System Never Lose Data and Test Time Data can be stored to an external USB memory stick to prevent data loss in the event of interruption of line power. The DAQ6510 also has an option to automatically restart scanning after a power interruption. If main power is lost, the DAQ6510 will re-start the scan when the power is restored. The new data will be stored in a separate data buffer with time-stamped measured data so that the lost time due to the power failure can be noted. Of most importance, there is no lost test time due to the instrument sitting...
Open the catalog to page 6DAQ6510 Data Acquisition and Logging, Multimeter System TSP ® technology also offers mainframe-less channel expansion. The KTTI-TSP is a user installable accessory card offering connectivity to TSP-Link technology. This channel expansion bus allows connecting multiple DMM6510’s, other TSP-enabled instruments, and any LAN-based instruments together to form a tightly-synchronized instrument system. Connection is provided with simple low cost Category 5 Ethernet crossover cabling. The system is organized in a master-subordinate configuration, essentially allowing the connected instruments to act...
Open the catalog to page 75 Pages
8 Pages
13 Pages
20 Pages
13 Pages
22 Pages
11 Pages
45 Pages
16 Pages
14 Pages
43 Pages
45 Pages
69 Pages
8 Pages
14 Pages
36 Pages
40 Pages
24 Pages
16 Pages
15 Pages
15 Pages
6 Pages
4 Pages
6 Pages
6 Pages
28 Pages
4 Pages
8 Pages
46 Pages
20 Pages
14 Pages
8 Pages
403 Pages
13 Pages
11 Pages
16 Pages
14 Pages
1 Page