COMBIVERT F6 DRIVE CONTROLLER 2.2 kW ... 450 kW EN
Open the catalog to page 1CONTENT System overview Benefits at a glance COMBIVERT F6 Variants Functional Safety Technical data COMBIVIS 6 Accessories KEB worldwide
Open the catalog to page 2SYSTEM OVERVIEW Automation with Drive stands for the optimally selected combination of control and automation with the drive package as the key to successful machine concepts. Let the following pages inspire you with regards to the diversity and performance of the COMBIVERT F6 drive controller, and help you to find a solution that reliably meets your requirements. IIOT Monitoring IIoT & Edge-Platform Remote Control CLOUD ROUTER CONNECT ROUTER RESET CONTROL SOFTWARE REMOTE CONNECT REMOTE CONNECT IIoT & Edge-Platform Control Software Visualisation Remote Control CLOUD ROUTER CONNECT ROUTER RESET...
Open the catalog to page 3BENEFITS AT A GLANCE OPTIMALLY SELECTED COMPONENTS Flexibility, functionality, efficiency and cost-effectiveness are the key requirements for today‘s drive system. In single-axis drive controller applications in the power range from 2.2 kW to 450 kW, COMBIVERT F6 covers these requirements and is the universal solution for all drive tasks. The COMBIVERT F6 with its capability to operate different motor types, the various real-time communication to higher-level controllers, the choice of integrated Safety function modules or the cooling concept is the perfect drive controller for every machine. The...
Open the catalog to page 4POWERFUL AND COMPACT DEVICE VARIANTS FOR SPECIAL REQUIREMENTS HIGH SPEED Whether for asynchronous, synchronous, synchronous reluctance or IPM motors: All motor types can be controlled and operated by the COMBIVERT F6 or COMBIVERT S6 drive controllers with high speeds of up to 120,000 revolutions per minute using the ASCL or SCL method with highly dynamic sensorless control. Depending on individual requirements, this is possible with or without an encoder. This means that nothing stands in the way of motor use in high-speed applications. • • • • Drives with outputs up to 450 kW Suitable sine filters...
Open the catalog to page 5COMBIVERT F6 - VARIANTS FUNCTIONAL SAFETY I/O 8 digital inputs 2 digital outputs 1 relay 2 analog inputs 1 analog output 24V DC supply INTERFACES CAN interface Realtime Ethernet Modbus LCD DISPLAY LCD Operator Ethernet Operator USB Operator STATUS LEDS DIAGNOSTIC INTERFACE MULTI ENCOCER INTERFACES Resolver, EnDAT, HIPERFACE, BISS, SSI, Incremental HTL/TTL, Incremental output MOTOR TERMINALS DC SUPPLY TERMINALS and braking resistor MAINS CONNECTIONS Safety over Universally usable for many motor technologies Highest performance in torque, speed and position control Uncompromising integration User-friendly...
Open the catalog to page 6COMPACT HIGHLY INTEGRATED AND ECONOMICAL APPLICATION MODULAR AND FLEXIBLE STO, SBC and speed/position related safety functions STO, SBC and speed related safety functions without encoder feedback REALTIME ETHERNET REALTIME ETHERNET REALTIME ETHERNET EtherCAT PROFINET POWERLINK EtherNet/IP Modbus TCP EtherCAT PROFINET Communication interface Communication interface Communication interface CAN DIAGNOSE RS232/485 Ethernet Modbus RTU Modbus TCP Brake handling Power-off DC-brake PID controller Round table function Recipe management Multi motor handling Anti cogging Liquid cooling management Protective...
Open the catalog to page 7SAFETY FUNCTIONS IN THE DRIVE BASIS FOR SAFETY COMPACT In the Compact variant, the COMBIVERT F6 and S6 drive controllers are equipped with Safe-Torque-Off (STO). SAFETY FUNCTIONS WITH SPEED AND POSITION MONITORING APPLICATION The device variant Application is available in two versions. In addition to STO, Module 1 adds safe brake control (SBC) which provides a safe 24 V supply for the brakes. Module 3 offers safe motion functionality according to IEC 61800-5-2 through speed and position detection using encoders. The error reaction time is shortened and costs are reduced by reducing the number of...
Open the catalog to page 8ENCODERLESS SAFETY FUNCTIONS PRO The Pro device variant of the COMBIVERT F6 and S6 drive controllers offers advanced safety functions without having to use a safety encoder. The device determines the safe velocity parameters from the pulse width modulation (PWM) of the motor supply. In addition to STO, Module 5 is equipped with a safe brake control (SBC), which provides a safe 24 V supply for braking operation as well as a monitoring of the switching status of the brake via microswitch evaluation. Module 5 also offers the option of controlling all available safety functions via Safety over EtherCAT...
Open the catalog to page 9COMBIVERT F6 230 V TECHNICAL DATA HOUSING Device size Rated output power Typical rated motor power Rated output current 230 V Rated output current 240 V (UL) Short-term current limit (60 s / max.) Rated input current 230 V Rated input current 240 V (UL) Rated switching frequency Mains phases Rated input voltage (AC) Input voltage range (AC) Input voltage range (DC) Mains frequency Output voltage Output frequency * The maximum possible output frequency depends on the switching frequency PUSH-THROUGH VARIANT
Open the catalog to page 10Device size Rated output power Typical rated motor power Rated output current 400 V Rated output current 480 V (UL) Short-term current limit (60 s / max.) [%] Rated input current 400 V Rated input current 480 V (UL) Rated switching frequency Mains phases Rated input voltage (AC) Input voltage range (AC) Input voltage range (DC) Mains frequency Output voltage Output frequency * The maximum possible output frequency depends on the switching frequency MECHANICAL DIMENSIONS AIR COOLING built-in push-through LIQUID COOLING built-in push-through ** air-cooled built-in variant
Open the catalog to page 11Device size Rated output power Typical rated motor power Rated output current 400 V Rated output current 480 V (UL) Short-term current limit (60 s / max.) Rated input current 400 V Rated input current 480 V (UL) Rated switching frequency Mains phases Rated input voltage (AC) Input voltage range (AC) Input voltage range (DC) Mains frequency Output voltage Output frequency * The maximum possible output frequency depends on the switching frequency ** Liquid-cooled only BUILT-IN VARIANT
Open the catalog to page 1224 Pages
16 Pages
4 Pages
4 Pages
264 Pages
8 Pages
32 Pages
16 Pages
16 Pages
8 Pages
12 Pages
40 Pages
8 Pages
24 Pages