KBWA Data Sheet
4Pages

{{requestButtons}}

Catalog excerpts

KBWA Data Sheet - 1

Hybrid Drive A Digital Drive with Analog Interface Primary Features Front Panel Power On/Off Switch Saves Time Easy to Install and Simple to Operate Does not require programming Up and running in less than 10 minutes. Motors Last Longer Provides overload protection, prevents motor burnout and eliminates nuisance tripping. UL approved as electronic overload Energy Saving Uses only the power the application requires Energy savings is realized by using variable motor speed vs. constant speed motors. Combines Soft Start with Variable Speed Adjustable Soft Start. "You get exactly what you need. Nothing more, nothing less." Includes: custom label, preset calibration, installing drive option and custom software. GFCI software* allows equipment to operate with Ground Fault Circuit Interruption circuit breakers or outlets. 'With factory programming. AC MOTOR SPEED CONTROL Hybrid Drive- KBWA SERIES. NEMA 1/IP 20 kbelectronics.com • ¡nfb@kbelectronics.com

Open the catalog to page 1
KBWA Data Sheet - 2

Additional Features Sensorless Flux Vector Control Flux Vector Compensation with Static Auto-Tune provides excellent speed regulation with high torque loads throughout the entire speed range. Auto energy saving at light loads. Smooth motor torque. Electronic Inrush Current Limit (EICL™) Protection Eliminates harmful inrush AC line current during power up. Provides smooth recovery to the previous set speed during a momentary power loss. Holding Torque at Zero Speed Resists motor shaft rotation when the drive is in "Stop" mode. Regeneration Protection Eliminates tripping due to high bus...

Open the catalog to page 2
KBWA Data Sheet - 3

'Requires factory programming, optional regenerative braking module is available. Dimensions - (Inches/mm)

Open the catalog to page 3
KBWA Data Sheet - 4

General Connection Diagram — (Motor) Ground Ground Ground V_^/ (Earth) (Earth) Adjustable Trimpots COMP: Slip Compensation Diagnostic LEDs Main Speed Potentiometer Remove Jumper to Install Forward-Stop-Reverse Switch On/Off AC Line Switch Automatic Start Mode: Jumper Installed (Factory Setting) Manual Start Mode: Jumper Removed (Forward-Stop-Reverse Switch (Supplied) Must be Installed) (Factory Setting) (Factory Setting) 208/230 Volt AC Line Input Outside Florida Call Toll Free (800) 221-6570 nfo@kbeleotronlos.oom • www.kbeleotronlos.oom

Open the catalog to page 4