Catalog excerpts
KBAC Hybrid Drive ™ A Digital AC Drive with Analog Interface Rugged Die-Cast Aluminum NEMA 4X / IP 65 Enclosure with Hinged Cover Primary Features Horsepower 1/8 to 5 HP, Jumper Selectable 1Ø & 3Ø Input 115/230/460 VAC, 50/60 Hz 3Ø Output 230/460 VAC 200% Starting Torque Diagnostic LED Status Indicators FDA Approved Finish* Benefits Saves Time Easy to Install and Simple to Operate Does not require programming or commissioning Up and running in less than 10 minutes. Motors Last Longer Proprietary CL Software Provides overload protection, prevents motor burnout and eliminates nuisance tripping. UL approved as electronic overload protector for motors. Energy Saving Uses only the power the application requires Replacing constant speed with variable speed will significantly reduce energy costs. Eliminates secondary enclosure No holes to drill, no switches to install. No need to derate drive for high starting torque applications. Combines Soft Start with Variable Speed Adjustable Soft Start. When an off the shelf drive does not meet your needs, we will work with you to provide a custom drive solution, Ready to Use, “Out-of-the-Box.” Customization includes: Pre-calibrating or programming of a stock control, adding a custom label or branding, custom software, PLC functions or designing a new control. GFCI Software, with factory programming, allows the equipment to operate with Ground Fault Circuit Interruption circuit breakers or outlets. *White case only.
Open the catalog to page 1Additional Features Sensorless Flux Vector Control Flux Vector Compensation with Static Auto-Tune provides excellent speed regulation with high torque loads throughout the entire speed range. Auto energy saving at light loads. Smooth motor torque. Electronic Inrush Current Limit (EICL™) Protection Eliminates harmful inrush AC line current during power up. Run/Fault Relay Can be used to turn equipment on or off, to signal a warning if the drive is put into “Stop” mode, or to signal if a fault has occurred. Start/Stop Switch Provides electronic “Start” and “Stop” functions. Provides smooth...
Open the catalog to page 2Ratings 115/230 VAC 1-Phase Input • 230 VAC 3-Phase Output Part No. 230 VAC 1-Phase Input • 230 VAC 3-Phase Output Part No. 460 VAC 3-Phase Input • 460 VAC 3-Phase Output Part No. *FDA approved (white case only). Specifications Maximum Load (% of Current Overload for 2 Minutes) Carrier, Switching Frequency (kHz) Output Frequency Resolution (Hz) Minimum Output Frequency to Motor (Hz) 9.53 242 Acceleration Time (Seconds) Deceleration Time (Seconds) Speed Range (Ratio) Speed Regulation (30:1 Speed Range, 0 – Full Load) (% Base Speed) Stalled Motor Trip Time (Seconds) Braking Operating...
Open the catalog to page 3General Connection Diagram Main Speed IFVT] trv-!! trvTl trvTl trv-!] trv-!] tnvTl tnv-!! JOG MAX MIN ACCEL DEC/I BOOST CL JOG COMP Auto Ride-Through Rated Motor RPM Operation Base Motor Freq Ground (Earth) Braking Mode Output Relay Stop Contact Torque Mode Ground (Earth) Outside Florida Call Toll Free (800) 221 -6570 info@kbelectronics.com • www.kbelectronics.com
Open the catalog to page 4All KB Electronics catalogs and technical brochures
-
KBVF Hybrid DriveTM
4 Pages
-
AC/DC Selection Chart
1 Pages
-
Hybrid Drives
2 Pages
-
Inverter Selection Guide
8 Pages
-
KBMM (SMT)
32 Pages
-
RFAC-24
1 Pages
-
KB Signal Isolator
6 Pages
-
KBWK-23D
40 Pages
-
KBVF series
44 Pages
-
KBMK
4 Pages
-
KBDA Data Sheet
4 Pages
-
KBWA Data Sheet
4 Pages
-
Build A Drive Program
4 Pages
-
KBAC Data Sheet
4 Pages
-
KBMA Data Sheet
4 Pages
-
KBMK Data Sheet
4 Pages
-
Product Selection Guide
12 Pages