Technical Specification Summary: Superthal™ Heating Modules - Flat Panels
Overview: Superthal™ Flat panels are advanced heating modules primarily used in the glass industry for heating feeder forehearths. They feature Kanthal® Super molybdenum disilicide (MoSi2) heating elements integrated into reinforced ceramic fiber, offering significant energy savings and precise temperature control.
Specifications:
  • Heating Elements: Kanthal® Super MoSi2 with straight or 90° bent terminals and fixed contacts.
  • Power Output: Maximum of 150 kW/m2 (14 kW/ft2).
  • Operating Temperature: Up to 1600°C (2910°F) in air atmospheres.
  • Dimensions: Maximum length of 1000 mm (39.4 in) and standard thickness of 125 mm (4.9 in).
Applications:
  • Feeder forehearths in the glass industry.
  • Metal holding furnaces.
Special Features:
  • Reduced energy consumption by up to 40%.
  • Precise and uniform temperature control.
Installation: Panels are designed for horizontal use and installation is straightforward, typically taking 1–2 days for a feeder. Kanthal® provides detailed technical advice on design and installation.
Contact Information: For more details, visit www.kanthal.com.
See more

Catalog excerpts

SUPERTHAL™ HEATING MODULES FLAT PANELS-1

SUPERTHAL™ HEATING MODULES FLAT PANELS TECHNICAL SPECIFICATION STEEPLY REDUCED ENERGY CONSUMPTION – PRECISE TEMPERATURE CONTROL Superthal™ Flat panels are commonly used in the glass industry as overhead heaters of feeder forehearths. The panels consist of Kanthal® Super molybdenum disilicide (MoSi2) heating elements integrated into reinforced ceramic fiber. The maximum power output is 150 kW/m2 (14 kW/ft2) and the maximum length to span the feeder is 1000 mm (39.4 in) The operating temperature is up to 1600°C (2910°F) in air atmospheres. The panels are specially designed to fit the requirements of each specific feeder in terms of power and dimensions. The general experiences from a great number of installations are that the energy consumption is steeply reduced, often up to 40%, and that a precise temperature control is obtained, contributing to an improved glass quality. APPLICATIONS — Feeder forehearths in the glass industry — Metal holding furnaces SPECIAL FEATURES — Reduced energy consumption — Precise temperature control — Uniform

 Open the catalog to page 1
SUPERTHAL™ HEATING MODULES FLAT PANELS-2

TECHNICAL SPECIFICATIONS SPECIFICATIONS The flat panels are heated by Kanthal® Super MoSi2 heating elements with the terminals either straight or 90° bent with fixed contacts. Element dimension and configuration depending on demands. ELEMENT TYPE KANTHAL® SUPER Straight or bent 90°, fixed contacts MAX CONTINUOUS OPERATING TEMPERATURE STANDARD THICKNESS The panels are designed for horizontal use. The standard thickness of the fiber is 125 mm (4.9 in). The dimensions and heating element layout on each panel are specially designed. Kanthal® can give detailed technical advice on design and installation....