Catalog excerpts

KANE451plus - 1

Kane International Limited Kane House, Swallowfielc, Welwyn Garden City, Hertfordshire, AL7 UG, UK with direct C02 measurement

Open the catalog to page 1
KANE451plus - 2

ANALYSER LAYOUT & FEATURES 5-6 2. BEFORE USING THE ANALYSER EVERY TIME 8-9 3. USING THE FOUR FUNCTION BUTTONS 10-12 4.3 LET-BY & TIGHTNESS TESTING 19-20 6. USING THE KANE451 plus AS A THERMOMETER OR 27-28 PRESSURE METER 7. MEASURING FLUE GASES 29 8. ANALYSER PROBLEM SOLVING 30 9. ANALYSER ANNUAL SERVICE & RE-CERTIFY 31-33 9.1 RETURNING YOUR ANALYSER TO KANE 32

Open the catalog to page 2
KANE451plus - 3

APPENDIX 1 - MAIN PARAMETER 41-43 ADDENDUM - OPTIONAL NITRIC OXIDE (NO) SENSOR 44-47

Open the catalog to page 3
KANE451plus - 4

KANE451plus Overview The KANE451plus Combustion Analyser measures carbon dioxide (CO2), carbon monoxide (CO), differential temperature and differential pressure. The direct measurement of CO2 is achieved using a Kane designed infra-red sensing system. CO2 is set to zero in fresh air automatically after the initial countdown. If “RESET GAS ZERO” is indicated ensure that the unit is in fresh air before pressing the button with an “Enter” symbol. It calculates oxygen (O2), CO/CO2 ratio, losses, combustion efficiency (Nett, Gross or Condensing) & excess air. The KANE451plus Combustion Analyser...

Open the catalog to page 4
KANE451plus - 5

ANALYSER LAYOUT & FEATURES Tasklight and infra-red emitter Menu controls Scroll up/down Function buttons x 4 Particle Filter Rotary Switch Battery Compartment (behind rubber sleeve) Water Trap “Battery Charging” indicator Temp and pressure connections

Open the catalog to page 5
KANE451plus - 6

Temperature Connections - Flue Probe Temperature (T1) Pressure Connections Flue Probe Temperature Plug be on the right hand side. Battery Charger Connection Watertrap Drain With Red Screw Plug ^Black Connector f (Plugs Into Flue Flue Probe Hose

Open the catalog to page 6
KANE451plus - 7

Battery Type This analyser has been designed for use with disposable alkaline batteries or rechargeable Nickel Metal Hydride (NiMH) batteries. No other battery types are recommended. WARNING The battery charger unit must only be used when NiMH batteries are fitted. Do not mix NiMh cells of different capacities or from different manufacturers. All four cells must be identical. Replacing Batteries Turn over the analyser, remove its protective rubber cover and fit 4 “AA” batteries in the battery compartment. Take great care to ensure they are fitted with the correct battery polarity. Replace...

Open the catalog to page 7
KANE451plus - 8

BEFORE USING THE ANALYSER EVERY TIME: Check the water trap is empty and the particle filter is not dirty: - To empty water trap, unscrew the red screw plug and re-tighten once it is empty. To change the particle filter, remove protective rubber cover, slide the water trap unit from the analyser, remove the particle filter from its spigot and replace. Reconnect the water trap unit and rubber protective cover. Connect the flue probe hose to the analyser’s flue gas inlet and connect the flue probe’s temperature plug to the T1 socket – check the plug’s orientation is correct - see Page 6. 2.1...

Open the catalog to page 8
KANE451plus - 9

2.2 STATUS DISPLAY Select “Status” on the dial to view the following: Replace alkaline batteries if less than 1 bar → Recharge NiMH batteries if less than 2 bars → Current time. Can be re-set via the “Menu”. → Current date. Can be re-set via the “Menu”. Shows number of days until next SAFETY WARNING This analyser extracts combustion gases that may be toxic in relatively low concentrations. These gases are exhausted from the back of the instrument. This analyser must only be used in well-ventilated locations by trained and competent persons after due consideration of all the potential...

Open the catalog to page 9
KANE451plus - 10

3. USING THE FOUR FUNCTION BUTTONS: Switching ON the Analyser Press / button to switch the unit ON. This must be done in fresh air to ensure that the analyser auto calibrates its sensors properly. When switched on, the analyser beeps and briefly displays battery %, fuel and pressure units. Its bottom line counts down from 90 until the sensors are ready to use. If the analyser will not auto calibrate, its sensors need to be replaced or recalibrated by an authorised repair centre. If an inlet temperature probe (optional) is connected into the T2 socket during its countdown, the measured...

Open the catalog to page 10
KANE451plus - 11

Backlight & Tasklight to switch the display's backlight and NOTE: Use of the backlight/tasklight significantly increases the current drain on the batteries. The analyser normally operates with the pump on. Press When the pump is switched off “-PO-" is displayed instead of the O2, CO & CO2 readings. The analyser also displays "PUMP OFF" on the top line approx every 40 seconds. NOTES: 1) The pump will not switch off if the CO reading is above 20ppm . This helps to protect the CO sensor from damage. 2) The pump will automatically switch itself off when the rotary switch is set to Menu, Status,...

Open the catalog to page 11
KANE451plus - 12

The top line briefly displays the log number. Note: This STORE function is inhibited in normal operation if the pump is switched off. Using / Buttons The function buttons below the symbols / / are used to navigate through the menu when the rotary switch is set to MENU – See USING THE MENU, Section 5.

Open the catalog to page 12
KANE451plus - 13

4.1 COMBUSTION TESTS: Insert the tip of the flue probe into the centre of the flue. The readings will stabilise within 60 seconds assuming the boiler conditions are stable. The rotary switch can be used to display the following information: RATIO Display → Fuel type can be changed via “Menu”. Press module). to print a full combustion test, (or send to PC via optional Wireless for 2+ seconds to log a full combustion report. SETTING USERFUEL Rotate dial to MENU, screen shows MENU SETUP

Open the catalog to page 13
KANE451plus - 14

Press \r , screen shows: Use ^ or ^7 to select USER 1, USER 2 or USER 3. Then press <H , the screen will typically show: NOTE: The actual numbers may be different.

Open the catalog to page 14
KANE451plus - 15

The display cursor will appear as a bar under the first character, in the case above: under the 0 of 0.351. Use / to change the character as appropriate, then press to move to the next character. This needs to be repeated for all four characters on all four display lines. To abort this setup sequence at any time without saving changes rotate the dial away from MENU. Pressing after setting the final character saves the user setting and exits the routine. ----------------SETUP EXIT ----------------O2/EFF display Press module). Hold Oxygen (%) left after combustion. Should be → 20.9% ± 0.1% in...

Open the catalog to page 15