ULTRAFLOW® 54 DN150-300
62Pages

{{requestButtons}}

Catalog excerpts

ULTRAFLOW® 54 DN150-300 - 1

Technical Description

Open the catalog to page 1
ULTRAFLOW® 54 DN150-300 - 2

TECHNICAL DESCRIPTION Kamstrup A/S · Technical description · 5512-876_M1_GB_12.2020

Open the catalog to page 2
ULTRAFLOW® 54 DN150-300 - 3

TECHNICAL DESCRIPTION

Open the catalog to page 3
ULTRAFLOW® 54 DN150-300 - 4

Kamstrup A/S · Technical description · 5512-876_M1_G

Open the catalog to page 4
ULTRAFLOW® 54 DN150-300 - 5

TECHNICAL DESCRIPTION 1 General description ULTRAFLOW® 54 DN150-300 is a static flow sensor based on the ultrasonic measuring principle. It is primarily used as a volume flow sensor for thermal energy meters such as MULTICAL®. ULTRAFLOW® 54 DN150-300 has been designed for use in heating and cooling installations where water is the heat-bearing medium. ULTRAFLOW® 54 employs ultrasonic measuring techniques and microprocessor technology. All calculating and flow measuring circuits are collected on one single board, thus providing a compact and rational design and, in addition, exceptionally...

Open the catalog to page 5
ULTRAFLOW® 54 DN150-300 - 6

TECHNICAL DESCRIPTION Electrical data Supply voltage 3.6 VDC ± 0.1 VDC Supply, galvanically coupled output module Powered by MULTICAL® (Y=1) Supply, galvanically separated output module (Y=2) 1) Mains supply 230 VAC +15/-30 %, 50 Hz 24 VAC ±50 %, 50 Hz Power consumption 1W Backup Integral SuperCap eliminates interruptions due to short-term power failures Supply, galvanically separated output module (Y=3) Battery 3.65 VDC, D-cell lithium Replacement interval 6-years @ tBAT  30 °C Mains supply 230 VAC +15/-30 %, 50 Hz 24 VAC ±50 %, 50 Hz Power consumption 1W Backup Integral SuperCap...

Open the catalog to page 6
ULTRAFLOW® 54 DN150-300 - 7

TECHNICAL DESCRIPTION Flow data Dynamic range Standard meter factor. Appears from ULTRAFLOW ® label. For other meter factors see paragraph 4. Saturation flow 125 Hz. Max. pulse frequency is maintained at higher flow. Table 1. Flow data. Wetted parts Housing Transducer holder Electronics box Base, cover Fitting hardware, distance piece for electronics box Signal cable (optional for separate ULTRAFLOW® 54) Silicone cable (3 x 0.5 mm2) Power supply cable 24/230 VAC (optional when selecting supply module) Cable with PVC-mantle (2 x 0.75 mm²) Housing, Cable Extender Box Base, cover Kamstrup A/S...

Open the catalog to page 7
ULTRAFLOW® 54 DN150-300 - 8

TECHNICAL DESCRIPTION 3 Type overview Nom. flow qp [m³/h] 150 250 400 600 1000 Flange facing type B, raised face according to EN 1092-1 Table 2. Type overview Kamstrup A/S · Technical description · 5512-876_M1_GB_12.202

Open the catalog to page 8
ULTRAFLOW® 54 DN150-300 - 9

TECHNICAL DESCRIPTION Type numbers of ULTRAFLOW® 54 for MULTICAL® The table below shows a list of type numbers for ULTRAFLOW® 54 ordered with MULTICAL® qp FCCN FDCN FECN FECP FECR FFCP FFCR FGCR FGDS Dynamic range qp:qi Meter factor Material (flow sensor housing) Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel XXX - code for final assembly, approvals etc. - determined by Kamstrup. Table 3. Type numbers of ULTRAFLOW® 54 for MULTICAL®. Type numbers of separate ULTRAFLOW® 54 FCCN FDCN FECN FECP FECR...

Open the catalog to page 9
ULTRAFLOW® 54 DN150-300 - 10

TECHNICAL DESCRIPTION Ordering details of separate ULTRAFLOW® 54 Type number composition of separate ULTRAFLOW® 54 Dynamic range and flow Connection and overall length Output module Supply module Final assembly and marking In addition to the basic variants listed in Table 4, you must select output module (Y), supply module (Z) as well as meter factor programming (CC) and pulse duration (E). Type numbers of output and supply modules Type number overview of output modules (Y) and supply modules (Z) for separate ULTRAFLOW® 54. Y 1 2 3 Output module Galvanically coupled module Galvanically...

Open the catalog to page 10
ULTRAFLOW® 54 DN150-300 - 11

TECHNICAL DESCRIPTION Programming options of meter factor and pulse durations Overview of programming options as to meter factors (CC) and pulse durations (E) for separate ULTRAFLOW® *) Spare part for ULTRAFLOW ® type 65-S/R/T. Configured 65-5-FGCR. No flow info. Table 6. Programming options as to meter factor (CC) and pulse durations (E) for ULTRAFLOW® 54 DN150-300. Based on a qp value a meter factor in Table 6 is chosen. The valid possible pulse durations are listed on the same line as the chosen meter factor. Example: For ULTRAFLOW® 54 qp 400 m3/h a meter factor of 100 liter/pulse...

Open the catalog to page 11
ULTRAFLOW® 54 DN150-300 - 12

TECHNICAL DESCRIPTION Please note that not all article numbers can be directly ordered. Some articles must be ordered via Kamstrup service department. Note Article number D-cell lithium battery with two-pole connector Fitting for D-cell battery Enclosed if battery supply or “No supply” is selected Plug for cable connection Enclosed if battery supply or “No supply” is selected (when ordering ULTRAFLOW®) Obligatory when changing from mains supply module to battery supply. Article number Cable between supply module and output module Enclosed if supply module is selected Article number Output...

Open the catalog to page 12
ULTRAFLOW® 54 DN150-300 - 13

TECHNICAL DESCRIPTION Article number Default for ULTRAFLOW® when ordered with MULTICAL® (when ordering ULTRAFLOW®) Optional for separate ULTRAFLOW® 5000-259 Mounting fitting for electronics box Enclosed (mounted) Short distance piece Long distance piece Collar band for long distance piece Cables ULTRAFLOW® 54 DN150-300, when ordered with MULTICAL®, is supplied with 2.5 metres signal cable, optionally 5 or 10 metres. The cable is mounted in the ULTRAFLOW® 54 electronics box and in MULTICAL® 6xx. When ULTRAFLOW® 54 is ordered with MULTICAL® 8xx, the calculator is supplied separately. Hence...

Open the catalog to page 13
ULTRAFLOW® 54 DN150-300 - 14

TECHNICAL DESCRIPTION All measurements are in mm, unless otherwise stated. Approx. weight kg Flange facing type B, raised face according to EN 1092-1 Table 7 Steel tube length C Kamstrup A/S · Technical description · 5512-876_M1_GB_1

Open the catalog to page 14
ULTRAFLOW® 54 DN150-300 - 15

TECHNICAL DESCRIPTION Figure 3. Cable Extender Box seen from the front (a) and from the side (b). Kamstrup A/S · Technical description · 5512-876_M1_GB_12.2020

Open the catalog to page 15
ULTRAFLOW® 54 DN150-300 - 16

TECHNICAL DESCRIPTION 6 Pressure loss Pressure loss in a flow sensor is stated as max. pressure loss at qp. According to EN 1434 max. pressure loss must not exceed 0.25 bar unless the energy meter includes a flow controller or functions as pressure reducing equipment. The pressure loss in a meter increases with the square of the flow and can be stated as: Q = kv  Dp where: Q = volume flow rate [m³/h] kv = volume flow rate at 1 bar pressure loss Dp = pressure loss [bar] FCCN FDCN FECN FECP FECR FFCP FFCR FGCR FGDS XXX - code for final assembly, approvals etc. - determined by Kamstrup. A few...

Open the catalog to page 16

All Kamstrup Instumenation catalogs and technical brochures

  1. flowIQ® 3200

    16 Pages

  2. HAN module

    4 Pages

  3. GSM6i module

    2 Pages

  4. MULTICAL® 603

    12 Pages

  5. Ball valve

    4 Pages

  6. Ball valve

    4 Pages

  7. MULTICAL 602

    4 Pages

Archived catalogs