1. Catalogs
  2. Kamstrup Instumenation
  3. ULTRAFLOW® 54 DN150-300

ULTRAFLOW® 54 DN150-300

ULTRAFLOW® 54 DN150-300
1 / 16 PagesView full catalog

ULTRAFLOW® 54 DN150-300

Product catalog summary
Overview: The ULTRAFLOW® 54 DN150-300 is a static ultrasonic flow sensor designed for heating and cooling installations. It offers a compact design, high accuracy, and durability with no moving parts, ensuring a large dynamic range and minimal wear.
Specifications: The sensor operates within a flow range of 150 m³/h to 1000 m³/h using a bidirectional ultrasonic technique based on the transit time method. It is compatible with Kamstrup MULTICAL® calculators and connects via a three-wire signal cable.
Approvals and Standards: The ULTRAFLOW® 54 is approved under MID 2014/32/EU for heating and cooling, complies with EN 1434:2015, and is CE-marked according to EU directives including EMC, LV, and PE.
Technical Data: Operating at 3.6 VDC, the sensor can be powered by MULTICAL® or a separate module. It is suitable for indoor use with an ambient temperature range of 5 to 55 °C and a protection class of IP67. The medium temperature ranges from 2 to 150 °C.
Flow Data: The sensor supports a dynamic range of 100:1 with specific pressure conditions to prevent cavitation and ensure accuracy.
Materials: Wetted parts are made of stainless steel and titanium, while the electronics box is made from thermoplastic materials.
Installation: The sensor can be installed in various orientations without requiring straight inlet or outlet sections under normal conditions. It must be installed in non-condensing environments with specific temperature and pressure conditions.
Connection to Calculator: The sensor can connect to MULTICAL® calculators either galvanically coupled or separated, with guidelines for cable lengths and connection types.
Type Numbers and Variants: Detailed type numbers are provided for different configurations, including options for separate flow sensors and output modules.
Additional Specifications: The ULTRAFLOW® 54 is available with various supply modules, including battery and AC options, and compatible output modules are listed for each type.
Programming Variants: Programming variants for meter factors and pulse durations are outlined, with a table showing configurations based on flow rates and pulse durations.
Accessories: Accessories include flange gaskets, supply modules, and miscellaneous items like short distance pieces and cable extender boxes.
Cables: Signal cables are available in lengths of 2.5, 5, or 10 meters, pre-mounted in the electronics box when ordered with MULTICAL® systems.
Contact Information: Contact details for Kamstrup A/S are provided, including address, phone numbers, email, and website.
See more

Catalog excerpts

ULTRAFLOW® 54 DN150-300-1

Data sheet For flow from 150 m³/h up to 1000 m³/h Ultrasonic flow sensor Compact design Static meter, no moving parts Large dynamic range No wear High accuracy Longevity

 Open the catalog to page 1
ULTRAFLOW® 54 DN150-300-2

Contents Application 2 Approvals 3 Technical data 4 Flow data 5 Materials 6 Type summary 6 Dimensional sketches 7 Pressure loss 8 Installation 9 Straight inlet ULTRAFLOW® 54 10 Operating pressure 10 Connection to calculator 10 Type numbers of ULTRAFLOW® 54 for MULTICAL® 12 Type numbers for separate ULTRAFLOW® 54 12 Type number composition of separate ULTRAFLOW® 54 13 Type numbers of output and supply modules 13 Programming variants of meter factor and pulse duration 14 Accessories 15 Application ULTRAFLOW® 54 is a static flow sensor based on the ultrasonic measuring principle. It is primarily...

 Open the catalog to page 2
ULTRAFLOW® 54 DN150-300-3

Type approval ULTRAFLOW® 54 is approved as a heat meter in accordance with MID 2014/32/EU: EC-Type Examination certificate MID-certificate acc. to module D M18 0200 ULTRAFLOW® 54 is approved as a cooling meter in accordance with DK-BEK 1178 – 06/11/2014: System designation Verification Please contact Kamstrup A/S for further information relating to type approval and verification. CE-marking ULTRAFLOW® 54 is marked in accordance with: – EMC-directive 2014/30/EU – LV-directive 2014/35/EU (when fitted with 230 VAC power supply) – PE-directive 2014/68/EU (category II) MID designation – Mechanical...

 Open the catalog to page 3
ULTRAFLOW® 54 DN150-300-4

Technical data Electrical data Supply voltage Supply, galvanically coupled output module (Y=1) Supply, galvanically separated output module (Y=2) * – Mains supply - Power consumption - Backup Supply, galvanically separated output module (Y=3) – Battery - Replacement interval – Mains supply - Power consumption - Backup Length of signal cable, flow sensor electronics box – Galvanically coupled output module (Y=1) 230 VAC +15/-30 %, 50 Hz 24 VAC ±50 %, 50 Hz <1W Integral SuperCap eliminates interruptions due to short-term power failures 3.65 VDC, D-cell lithium 6-years @ tBAT < 30 °C 230 VAC +15/-30...

 Open the catalog to page 4
ULTRAFLOW® 54 DN150-300-5

Technical data Mechanical data Metrological class Environmental class Ambient temperature Protection class Medium in flow sensor Water (recommended water quality as in CEN TR 16911 and AGFW FW510) Medium temperature 2…150 °C (Heat and heat/cooling meters) 2…130 °C (Heat/cooling meters) 2…50 °C (Cooling meters) Storage temperature (empty sensor) Pressure stage At medium temperatures above 90 °C or below ambient temperature the electronics box must be wall-mounted or mounted via the enclosed distance piece. Flow data Nom. diameter Meter factor * Dynamic range qp:qi [mm] [imp./l] DN150 DN150 DN150...

 Open the catalog to page 5
ULTRAFLOW® 54 DN150-300-6

Wetted parts Housing Transducer holder Transducer Titanium Gaskets Fibre Fitting hardware and distance piece for the electronic box Signal cable Silicone cable (3 x 0.5 mm²) Power supply cable 24/230 VAC (optional) Cable with PVC mantle (2 x 0.75 mm²) Type summary Flange EN 1092-1. Flange facing type B, raised face.

 Open the catalog to page 6
ULTRAFLOW® 54 DN150-300-7

Dimensional sketches Flange EN 1092-1. Flange facing type B, raised face. Nom. diameter Steel tube length C Approx. weight

 Open the catalog to page 7
ULTRAFLOW® 54 DN150-300-9

Installation Prior to installation of the flow sensor, the system should be flushed. Correct flow sensor position (inlet or outlet) appears from the front label of MULTICAL®. The flow direction is indicated by an arrow on the flow sensor. Please note: ULTRAFLOW® 54 may be lifted in the lifting rings only. Pressure stage ULTRAFLOW® 54: PN16, PS16/PN25, PS25. See marking on label. Temperature of medium, ULTRAFLOW® 54: 2…150 °C/ 2…130 °C/2…50 °C. See marking on label. Mechanical environment: M1 and M2 (fixed installation with minimum vibration and fixed installation with considerable or high vibration...

 Open the catalog to page 9
ULTRAFLOW® 54 DN150-300-10

Straight inlet ULTRAFLOW® 54 ULTRAFLOW® 54 requires neither straight inlet nor outlet in order to fulfil the Measuring Instruments Directive (MID) 2014/32/EU and EN 1434:2015. Only in case of heavy flow disturbances before the meter will a straight inlet section be necessary. We recommend following the guidelines in CEN CR 13582. Operating pressure In order to prevent cavitation, the back pressure at ULTRAFLOW® 54 (the pressure at the flow sensor outlet) must be min. 1.5 bar at qp and min. 2.5 bar at qs. This applies to temperatures up to approx. 80 °C. Connection to calculator ULTRAFLOW® 54...

 Open the catalog to page 10
ULTRAFLOW® 54 DN150-300-11

Connection to calculator ULTRAFLOW® 54 and MULTICAL®, galvanically separated If ULTRAFLOW® 54 and MULTICAL® are connected via output module (Y=2 or 3), ULTRAFLOW® 54 is galvanically separated from MULTICAL®. Maximum cable length depends on calculator. Note: Flow info cannot be read. Three-wire connection, MULTICAL® 602/603/801 via output module (Y=2 or 3). Two-wire connection, MULTICAL® 801 via output module (Y=2). Two-wire connection, MULTICAL® 602-D/603-G via output module (Y=2) and external 24 VDC supply. When using long signal cables, careful consideration is required in connection with installation....

 Open the catalog to page 11
ULTRAFLOW® 54 DN150-300-12

Type numbers of ULTRAFLOW® 54 for MULTICAL® Type number * Max. flow Connection PN Length qS [m³/h] [mm] [bar] [mm] 300 500 800 800 800 1200 1200 2000 2000 Meter factor [imp./l] Material flow sensor housing Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel * XXX-code pertaining to final assembly, approvals etc. – determined by Kamstrup A/S. Some variants may not be available in national approvals. Type numbers for separate ULTRAFLOW® 54 Type number * Material flow sensor housing Stainless steel Stainless...

 Open the catalog to page 12
ULTRAFLOW® 54 DN150-300-13

Type number composition of separate ULTRAFLOW® 54 In addition to the basic variants output module (Y), supply module (Z) as well as meter factor (CC) and pulse duration (E) must be selected. The variant with galvanically coupled output module (Y=1) is solely for use together with MULTICAL®. The variant with galvanically separated output module (Y=2 or 3) is used in the following situations: A More than 10 m cable length between MULTICAL® and ULTRAFLOW® 54 is required (Y=2). B As flow sensor no. 2 in connection with MULTICAL®. If two flow sensors are used together with MULTICAL®, one must include...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.