Data sheet PQT Controller MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 • • • • • Controller for power or flow Possibility to further limit t2 and ∆t S imple setup and commissioning Output for three-point valve motor E xternal 24 VAC supply for
Open the catalog to page 1MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 Contents Description 3 Installation 3 Cable connections 4 Mode of operation 5 Typical PQT installation 6 Technical data 6 Ordering 7 Configuration 7 Display readings 8
Open the catalog to page 2MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 Description HC-003-43 is a versatile control module for use in MULTICAL® 403, MULTICAL® 603 and MULTICAL® 803 energy meters. The PQT Controller is for applications to optimize energy consumption. The PQT Controller works together with the MULTICAL® energy meter and reads the meter’s flow, power, temperature difference and outlet temperature. The read data is used together with the limit values configured in the module to control the connected motor valve. The controller is fully programmable and can be selected to regulate according to one or more...
Open the catalog to page 3MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 Cable connections Terminals Max cable size 1.5 mm² Motor Terminal 150: Motor Up Terminal 151: Motor Com Terminal 152: Motor Dn Test Short circuit to open Short circuit to close External power Terminal 98: 24 VAC Terminal 97: 24 VAC Connection diagram When the power supply and motor valve are connected, you can test whether the valve opens and closes correctly by short-circuiting the Test-Up and Test-Dn solder pads, e.g. by using a small screwdriver. If the valve runs in the opposite direction, the supply cables Dn Y2 and Up Y1 must be exchanged.
Open the catalog to page 4MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 Mode of operation PQT Controller is designed with more set-points and gain-factors. One part controls power and flow (PQ control), another part controls the outlet temperature and differential temperature (t2∆t control). The control will always adjust towards the most restrictive limit, whether it is flow, power, t2 or ∆t. PQ control Flow set‐point Power set‐point PQ control The control of power and flow takes place in the same part of the controller as the power is calculated on the basis of flow. For the PQ control to be active, one or both...
Open the catalog to page 5MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 Consumer T2 Outlet Motor valve Technical data Physical For installation in MULTICAL® 403, MULTICAL® 603 and MULTICAL® 803. Mechanical data Dimensions (L x W x D) Weight MULTICAL® Supply " Data refresh rate Data from the meter to the module are refreshed each time the meter completes an integration. Integration mode is defined by the meter’s L-code. Dynamic range Power Flow Motor Outputs Voltage Control function Characteristic Valve travel time Mutual blocking Short-circuit safe Galvanic isolation 24 VAC Three-point switch Linear 120…460 s Yes Yes >...
Open the catalog to page 6MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 Technical data Environment Operational temperature Humidity Markings/ approvals Programming Configuration/firmware 5 °C – 55 °C 25 – 85 % RH non-condensing CE, MID together with the type approval of MULTICAL® 403, MULTICAL® 603 and MULTICAL® 803. Via the optical readout head or the multipole connector on the module using METERTOOL HCW Description PQT Controller USB configuration cable for H/C-modules Infrared optical readout head w/USB A plug Transformer 230/24 VAC METERTOOL HCW Configuration Configuration of the PQT Controller can be done when...
Open the catalog to page 7MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 Display readings Module information The module information can be read by choosing ”TECH loop” on the MULTICAL® meter. Module placed in module slot 1: Choose menu 2-101 in ”TECH loop” Module placed in module slot 2: Choose menu 2-201 in ”TECH loop” Module placed in module slot 3: Choose menu 2-301 in ”TECHloop” Module placed in module slot 4: Choose menu 2-401 in ”TECH loop” Menu index Module configuration Module firmware and revision Module serial number Display example Module control information * * Shows the time in milliseconds that the valve is...
Open the catalog to page 8All Kamstrup Instumenation catalogs and technical brochures
-
MULTICAL® 21 & flowIQ® 2101
20 Pages
-
flowIQ® 3200
16 Pages
-
MULTICAL® 21 & flowIQ® 2200
4 Pages
-
OMNIPOWER® three-phase
20 Pages
-
IP101i module
4 Pages
-
HAN module
4 Pages
-
GSM6i module
2 Pages
-
Data pulse module
4 Pages
-
GSM6i/RF modul
2 Pages
-
Facts Advantages Benefits
4 Pages
-
MULTICAL® 603
12 Pages
-
Ball valve
4 Pages
-
Modbus RTU Modbus/KMP TCP/IP
20 Pages
-
MULTICAL® 603 MULTICAL® 803
12 Pages
-
2G/4G Network Module
8 Pages
-
Modbus RTU inputs (In-A, In-B)
12 Pages
-
LON TP/FT-10 inputs (In-A, In-B)
12 Pages
-
Ball valve
4 Pages
-
ULTRAFLOW® 54 DN150-300
62 Pages
-
ULTRAFLOW® 54 DN150-300
16 Pages
-
TemperatureSensor 83
8 Pages
-
Temperature sensors and pockets
12 Pages
-
ULTRAFLOW® 44
2 Pages
-
ULTRAFLOW® 44 DN15-125
20 Pages
-
MULTICAL 602
4 Pages
Archived catalogs
-
2021 flowIQ® 3100
4 Pages
-
2015 flowIQ® 3100
4 Pages