OMNIPOWER® three-phase
20Pages

{{requestButtons}}

Catalog excerpts

OMNIPOWER® three-phase - 1

Data sheet OMNIPOWER® three-phase • • • • • • • • Three-phase residential meter Prepared for Smart Home applications Optimised for Smart Metering systems Secured against tampering Resistant to errors in the supply network Ultra-low power consumption Remote firmware update Power quality measurements according to EN 50160 • Type approved according to: - Active energy EN 50470-1 (MID) EN 50470-3 (MID) - Active energy and reactive energy IEC 62052-11 IEC 62053-21 IEC 62053-23 • Communication proto

Open the catalog to page 1
OMNIPOWER® three-phase - 2

OMNIPOWER® three-phase meter Content Application 3 Functions 4 Approvals 8 Technical data 8 Connections 10 Communication 10 Consumer communication channel (CCC) module 10 Typical accuracy charts 11 Configuration – hardware 12 Configuration – software 13 Installation 17 Safety and installation guidelines 17 Dimensions 18 Accessories 19

Open the catalog to page 2
OMNIPOWER® three-phase - 3

OMNIPOWER® three-phase meter Application Kamstrup OMNIPOWER® three-phase meter is a direct connected electricity meter for registration of electric energy. The meter is fully electronic without movable parts. Thus, energy registration is not affected by shock or impact during transport and mounting. Furthermore, measurements are correct no matter the physical mounting direction. The shunt measuring principle secures good linearity and a considerable dynamic range. At the same time, the shunt measuring principle is immune to magnetism and DC currents. The easily readable display scrolls...

Open the catalog to page 3
OMNIPOWER® three-phase - 4

OMNIPOWER® three-phase meter Display Kamstrup OMNIPOWER® three-phase meter is provided with a Liquid Crystal Display (LCD). The registers that can be read from the display depend on the chosen configuration. It is also possible to remotely configure the display. The display configuration is constructed as three independent display lists: One for automatic shift function, one for manual shift function and one for battery-powered shift function. The display is constructed of segments as shown in the figure below. Module indication Quadrant indicator Text field 9-digit value field Unit field...

Open the catalog to page 4
OMNIPOWER® three-phase - 5

OMNIPOWER® three-phase meter Display The automatic shift function (scroll) changes between the selected readings every 10 seconds. Up to 16 readings can be selected. The manual shift function changes through activation of the left push button. Up to 30 readings and the reading order can be selected. However, it is not possible to deselect the legal readings. If the battery-operated shift function is selected, it becomes possible to read the display, also when the meter is not power supplied. Up to 8 readings can be selected, and shifts between readings are made by activating the push...

Open the catalog to page 5
OMNIPOWER® three-phase - 6

OMNIPOWER® three-phase meter Plug-in modules Kamstrup OMNIPOWER® three-phase meter can be mounted/retrofitted with plug-in modules without subsequent reverification. The module communicates with the meter’s microprocessor via an internal data bus. This provides innumerable functional possibilities such as extra pulse output, tariff, load control and data communication via e.g. GSM/GPRS, and M-Bus. Optical reading An optical interface is placed on the front of the meter. This optical connection can be used to read data or configure e.g. display set-up, meter number and other settings....

Open the catalog to page 6
OMNIPOWER® three-phase - 7

OMNIPOWER® three-phase meter Load profile* Load profiles can be configured to 15, 30 or 60 min. according to the integration period and for all four quadrants. The number of generated profiles corresponds to the selected energy type for the meter. Logging depth in days: Minutes A+ A+/AA+/A-/R+/RA+/A-/R1/R2/R3/R4 A+/A-/R+/R-/R1/R2/R3/R4 * Load profile for Austria is limited to 60 days with a fixed integration period of 15 min The logging depths listed above apply to OMNIA 3.0 firmware and newer. Analysis logger Kamstrup OMNIPOWER® three-phase meter is provided with a configurable analysis...

Open the catalog to page 7
OMNIPOWER® three-phase - 8

OMNIPOWER® three-phase meter Approvals Kamstrup OMNIPOWER® three-phase meter is type approved according to the Measuring Instruments Directive (MID) for active positive energy and according to the national requirements for other energy types, where required. Approval Norm Type test according to: – Active energy EN 50470-1 EN 50470-3 – Reactive energy and active energy IEC 62052-11 IEC 62053-21 IEC 62053-23 Various Norm Terminal DIN 43857 S0 pulse output DIN 43864 Optical reading DLMS/COSEM OBIS/EDIS codes IEC 62056-61 Technical data Measuring principle – Current – Voltage Nominal voltage Un...

Open the catalog to page 8
OMNIPOWER® three-phase - 9

OMNIPOWER® three-phase meter Technical data Protection class Protection class Relative humidity Weight Application area Internal consumption* IP54 II < 75 % year’s average at 21 °C < 95 % less than 30 days/year, at 25 °C 1300 g with breaker/1000 g without breaker Indoors or outdoors in suitable meter cabinet OMNIPOWER® three-phase meter Without breaker With breaker Maximum power consumption of the current circuits with basic current Maximum power consumption of the voltage circuits * Measured by notified body during type test. Measured at phase L1. Materials Data storage Display Meter...

Open the catalog to page 9
OMNIPOWER® three-phase - 10

OMNIPOWER® three-phase meter Connections Terminals Size 35 mm² Screws Elevator terminals For use with connection: Multi-cored 7-cored ≥ 6 mm² ≥ 6 mm² Pz 2 or straight slot Torque 2.5 - 3 Nm Voltage output Screws 0.25 - 1.5 mm², 5 mm terminal forks TORX Tx 10 Torque 1 Nm Communication Kamstrup OMNIPOWER® three-phase meter can be supplied or retrofitted with communication modules. The modules function as inputs and outputs for the meter. Mounting of modules does not require subsequent verification of the meter. Communication Modules Serial M-Bus GSM/GPRS Serial RS-485 or RS-232 communication...

Open the catalog to page 10
OMNIPOWER® three-phase - 11

OMNIPOWER® three-phase meter Typical accuracy charts Påvirkning Influence fromfra temperaturvariation temperature variation Load curve Erroriin % Fejl % Påvirkning fra spændingsvariation Influence from voltage variation Temperature Temperatur Temperatur Temperature Influence from frequency variation at In 0,5 MPE (Maximum Permissible Error) Error composed of: • current load • voltage variation • frequency variation • temperature variation

Open the catalog to page 11