MULTICAL® 603 MULTICAL® 803 - 1

Datagrams description 2G/4G module HC-003-80

Open the catalog to page 1
MULTICAL® 603 MULTICAL® 803 - 3

1 INTRODUCTION The 2G/4G module for MULITCAL® 603 and MULITCAL® 803 is configurable, whereby it can be configured to send out different datagrams. A datagram is defining, which registers a specific module configuration is transmitting. Furthermore, transmission interval and transmission power for the module can be configured. The configuration of the 2G/4G module is described by the XX-YY-ZZZ code. XX: Module type - the physical hardware YY: System configuration – for 2G/4G module: the transmitting interval ZZZ: Datagram – the data registers This document provides an overview of the...

Open the catalog to page 3
MULTICAL® 603 MULTICAL® 803 - 4

2 MODULE DATAGRAM EXPLANATION The 2G/4G module is a versatile communication module, which can be configured to send out different datagrams. A datagram is a collection of registers the module will send out. A datagram is also called a data package or a data telegram. Not all registers are available in all meters. E.g. will cooling register E3 only be available in a meter configured as a cooling or combined heat/cooling. It will not be available in a heat meter. For reading out Target registers, the wanted registers must be defined in the RR-configuration (logger content). If datagrams...

Open the catalog to page 4
MULTICAL® 603 MULTICAL® 803 - 5

Data type: A note indicates that some action has to be taken. - HCC - OMS - MSC - FDB 1 byte integer value 2 byte integer value shown as blank field, as this is mostly used. 2 digit BCD coded value 4 digit BCD coded value 6 digit BCD coded value 8 digit BCD coded value Heat/Cooling Coding Coded according to OMS Manufactory Specific Coding Fixed Data Block If marked with X, the register is included in a Heat meter If marked with X, the register is included in a Cooling meter If marked with X, the register is included in a combined Heat/Cooling meter If marked with X, the register is included...

Open the catalog to page 5
MULTICAL® 603 MULTICAL® 803 - 6

3 2G/4G DATAGRAMS This table shows the available transmission intervals and datagrams for high power supplied MULTICAL® 603 and MULTICAL® 803 meters. Please note: It is the combination of the YY and the ZZZ that identifies a datagram XX Module Type 2G/4G inputs (In-A, In-B) System Configuration 5 minute transmission 15 minute (quarter) transmission 60 minute (hour) transmission Datagrams Standard datagram Standard datagram + Power Max Month MULTICAL® 803 datagram (all energy registers)

Open the catalog to page 6
MULTICAL® 603 MULTICAL® 803 - 7

4 2G/4G DATAGRAMS FOR MULTICAL® The following YY-ZZZ datagrams are applicable for MULTICAL® 603 and MULTICAL® 803. 4.1 80-20-110: 5 MINUTE TRANSMISSION, STANDARD DATAGRAM YY = 20 ZZZ = 110 Register name Heat Energy E1 Heat Energy E2 Cooling Energy E3 Cooling Energy E3 HC Inlet Energy E4 Energy E8 Energy E9 Energy E10 Energy E11 COP Heat Energy A1 Heat Energy A2 Volume V1 Volume V2 Flow V1 Flow V2 Power t1 t2 t3 t4 Mass M1 Mass M2 P1 actual – part 1 P2 actual – part 1 Tariff TA2 Tariff TA3 Tariff TA4 Pulse input A1 Pulse input B1 Info bits Operating hours Error hour counter Register Origin...

Open the catalog to page 7
MULTICAL® 603 MULTICAL® 803 - 8

4.2 80-22-110: 15 MINUTE (QUARTER) TRANSFER, STANDARD DATAGRAM YY = 22 ZZZ = 110 Register name Heat Energy E1 Heat Energy E2 Cooling Energy E3 Cooling Energy E3 HC Inlet Energy E4 Energy E8 Energy E9 Energy E10 Energy E11 COP Heat Energy A1 Heat Energy A2 Volume V1 Volume V2 Flow V1 Flow V2 Power t1 t2 t3 t4 Mass M1 Mass M2 P1 actual – part 1 P2 actual – part 1 Tariff TA2 Tariff TA3 Tariff TA4 Pulse input A1 Pulse input B1 info bits Operating hours Error hour counter Register Origin Data type

Open the catalog to page 8
MULTICAL® 603 MULTICAL® 803 - 9

4.3 80-24-110: 60 MINUTE (HOURLY) TRANSFER, STANDARD REGISTERS YY = 24 ZZZ = 110 Register name Heat Energy E1 Heat Energy E2 Cooling Energy E3 Cooling Energy E3 HC Inlet Energy E4 Energy E8 Energy E9 Energy E10 Energy E11 COP Heat Energy A1 Heat Energy A2 Volume V1 Volume V2 Flow V1 Flow V2 Power t1 t2 t3 t4 Mass M1 Mass M2 P1 actual – part 1 P2 actual – part 1 Tariff TA2 Tariff TA3 Tariff TA4 Pulse input A1 Pulse input B1 info bits Operating hours Error hour counter Register Origin Data type

Open the catalog to page 9
MULTICAL® 603 MULTICAL® 803 - 10

Datagram description 2G/4G 4.4 80-22-111: 15 MINUTE (QUARTER) TRANSFER, STANDARD DATAGRAM + POWER MAX MONTH YY = 22 ZZZ = 111 Register name Heat Energy E1 Heat Energy E2 Cooling Energy E3 Cooling Energy E3 HC Inlet Energy E4 Energy E8 Energy E9 Energy E10 Energy E11 COP Heat Energy A1 Heat Energy A2 Volume V1 Volume V2 Flow V1 Flow V2 Power t1 t2 t3 t4 Mass M1 Mass M2 P1 actual – part 1 P2 actual – part 1 Tariff TA2 Tariff TA3 Tariff TA4 Power Max info bits Operating hours Error hour counter Register Origin Data type

Open the catalog to page 10
MULTICAL® 603 MULTICAL® 803 - 11

4.5 80-24-112: 60 MINUTE (HOURLY) TRANSFER, MC803 DATAGRAM (ALL ENERGY REGISTERS) YY = 24 ZZZ = 112 Register name Heat Energy E1 Heat Energy E2 Cooling Energy E3 Cooling Energy E3 HC Inlet Energy E4 Outlet Energy E5 Tap water Energy E6 Tap water Energy E7 Energy E8 Energy E9 Energy E10 Energy E11 Energy E12 Energy E13 Energy E14 Energy E15 Energy E16 Volume V1 Volume V2 Flow V1 Flow V2 Power t1 t2 t3 t4 Tariff TA2 Tariff TA3 Tariff TA4 infobits Operating hours Error hour counter Register Origin Data type

Open the catalog to page 11
MULTICAL® 603 MULTICAL® 803 - 12

Document created and released. 80-20/22/24-110, 80-22-111, 80-24-112

Open the catalog to page 12