Data pulse module

Data pulse module

Data pulse module

Product catalog summary
Overview: The data pulse module is designed for electricity meters to facilitate pulse outputs, pulse inputs, and serial communication without direct access to the meter. It supports galvanically separated communication and pulse outputs, and can be easily mounted or replaced without reverification.
Application: The module serves as pulse outputs 2 and 3, and supports RS-232 or USB data communication. It can retransmit various pulse types to data loggers or CTS equipment, with configurable pulse rates and widths. It also collects pulses from other meters, such as water meters, with a configurable pulse division factor.
Technical Data: The module is powered internally by the electricity meter, consuming less than 0.05 W. It operates within a temperature range of -40 °C to +70 °C and supports a relative humidity of less than 95% non-condensing. The module weighs approximately 27 g and measures 42 x 92 x 17 mm.
Pulse Output: Configurable for 1 to 1000 pulses/kWh with pulse widths of 30 or 80 ms. The maximum voltage is 400 VAC or DC, with a power dissipation of 400 mW.
Pulse Input: Designed for potential-free switches with a maximum cable length of 20 m and a frequency of up to 25 Hz. The pulse input can be scaled using a pulse division factor.
Installation: The module is mounted in the modular space of the electricity meter under a transparent lid. It includes specific terminals for pulse output, pulse input, and serial communication.
Order Specification: The document lists part numbers for the data pulse module and associated accessories like USB cables and RS-232 converters.
See more

Catalog excerpts

Data pulse module-1

Data sheet Data pulse module for electricity meters • • • • • • • Reading without direct access to the meter Galvanically separated serial communication Collection of pulses from other meters Additional configurable pulse outputs Galvanically separated pulse outputs Easily mounted in the electricity meter No rev

 Open the catalog to page 1
Data pulse module-2

Data pulse module Application The data pulse module is used as pulse outputs no. 2 and 3, as an input for pulses and for serial RS-232 or USB data communication (using attached cable). The pulse outputs can be configured to retransmit A+, A+/A- or A+/R+ pulses of the electricity meter to data loggers or CTS equipment. Pulse outputs can be configured for 1 – 1000 pulses/ kWh and with a pulse width of 30 or 80 ms. The pulse input offers to collect pulses from other meters, e.g. a water meter with potentialfree output. The input can be scaled using a configurable pulse division factor. The data/communication...

 Open the catalog to page 2
Data pulse module-3

Data pulse module Technical data Pulse output The pulse outputs 2 and 3 of the electricity meter is configured as follows: 1 pulse/kWh As standard, the pulse outputs send 1000 pulses/kWh, but can be configured for a pulse division factor (1 - 1000). In addition, the pulse width can be configured for 30 or 80 ms. See technical description. Pulse input For potential-free switch, e.g. reed-switch or relay Cable length, max Leak current, switch max It is possible to scale the reading of the pulse input by a ”pulse division factor”. See technical description. Installation The module is mounted in...

 Open the catalog to page 3
Data pulse module-4

Data pulse module Order specification Type No. 6850-075 6699-098 6699-106 Description Data pulse module, dual pulse, 9600 USB with 3-wire cable RS 232 converter with cable

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.