1. Catalogs
  2. Kamstrup Instumenation
  3. BACnet® MS/TP inputs (In-A, In-B)

BACnet® MS/TP inputs (In-A, In-B)

BACnet® MS/TP inputs (In-A, In-B)

BACnet® MS/TP inputs (In-A, In-B)

Product catalog summary
Introduction
The document introduces a high-performance BACnet® MS/TP communication module compatible with MULTICAL® 403, 603, and 803 energy meters. This module allows integration into building automation systems and industrial installations, ensuring compatibility with BACnet® standards.

Specifications
The module is BTL certified, compatible with ANSI/ASHRAE-135 and ISO 16484-5, and supports BACnet® COV notifications. It features RS-485 galvanic isolation and supports automatic baud rate detection from 9600 to 115200 baud.

Installation
The module is easily mounted in a free module space within the meter. Configuration may be required for specific BACnet® MAC addresses, which can be performed using METERTOOL HCW. The module is powered by the meter's internal 230 VAC or 24 VAC supply.

Cable Connections
Terminals support a maximum cable size of 1.5 mm². RS-485 communication requires a twisted shielded pair cable, with the shield connected to the GND terminal. Line-topology connections are recommended, with 120 Ohm resistors terminating the communication line.

Communication
The module supports BACnet® BTL certification, with addressing capabilities as a master (MAC address range 1-127) or slave (MAC address range 128-254). The BACnet® Object name and identifier provide further device description.

Data and Alarms
The module supports a wide range of data registers, including flow, energy, and temperature metrics. It also provides info codes for alarms related to flow errors, temperature errors, and other system issues.

Technical Data
The module dimensions are 90 x 35 x 14 mm, weighing less than 45g. It operates within a temperature range of 5 °C to 55 °C and humidity of 25-85% RH non-condensing. It is CE and MID approved.

Ordering and Configuration
Ordering information includes the module and accessories like a USB configuration cable and infrared optical readout head. Configuration settings are managed via METERTOOL HCW.

Displayed Information
Module information can be accessed through the MULTICAL® display by selecting the appropriate menu in the “TECH loop”.
See more

Catalog excerpts

BACnet® MS/TP inputs (In-A, In-B)-1

Data sheet BACnet® MS/TP inputs (In-A, In-B) MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 • BTL certified and listed • Compatible with ANSI/ASHRAE-135, ISO 16484-5 • Supports BACnet® COV notifications • RS-485 galvanic isolated from BACnet® is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineer

 Open the catalog to page 1
BACnet® MS/TP inputs (In-A, In-B)-2

BACnet® MS/TP, inputs (In-A, In-B) MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 Contents Installation 2 Cable connections Communication from module BACnet® data Technical data Ordering 7 Configuration 7 Displayed information Introduction A high-performance BACnet® module has been introduced with MULTICAL® 403, MULTICAL® 603 and MULTICAL® 803 energy meters. BACnet® the MS/TP communication module allows MULTICAL® meters to be integrated into a building automation system or to be part of industrial installations. The module is BTL certified and listed, which guarantees compatibility with BACnet® standard....

 Open the catalog to page 2
BACnet® MS/TP inputs (In-A, In-B)-3

BACnet® MS/TP, inputs (In-A, In-B) MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 Cable connections Terminals Max cable size 1.5 mm² Pulse inputs Terminal 65: Pulse In-A(+) Terminal 66: Pulse In-A(-) Terminal 67: Pulse In-B(+) Terminal 68: Pulse In-B(-) Pulse inputs The module is equipped with two pulse inputs, In-A and In-B, to collect and accumulate pulses, e.g. from water and electricity meters. The pulse inputs are physically placed on the module. However, the accumulation and logging of values are performed by the MULTICAL® calculator. When installing a module with pulse inputs in slot 2 of MULTICAL®...

 Open the catalog to page 3
BACnet® MS/TP inputs (In-A, In-B)-4

BACnet® MS/TP, inputs (In-A, In-B) MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 Communication from module Protocol BACnet® BTL certified according with ASHRAE 135 and ISO 16484-5. BACnet® MS/TP Addressing The module can be addressed as master in the MAC address range 1-127 and as a slave when configured in the MAC address range 128-254. When ordering the modules together with a MULTICAL® the BACnet® MAC address is determined by the last two or three digits of the customer number similar the BACnet® Object identifier is also set to the meter’s costumer number. Note: When the MAC address is in the...

 Open the catalog to page 4
BACnet® MS/TP inputs (In-A, In-B)-5

BACnet® MS/TP, inputs (In-A, In-B) MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 BACnet® data The BACnet module can be used in any of the MULTICAL® XX3 meters. However, some registers found in MULTICAL® 803 does not exist in MULTICAL® 403 and 603, and some registers found in MULTICAL® 603 does not exist in MULTICAL® 403. If a meter does not have a requested register, the module will set the BACnet Reliability property of that register to “No Sensor”. Following registers are included in the BACnet Object Map: Analog Input Flow V1 actual Flow V2 actual Actual Power Actual Power 2 (E14/E16) t1 actual...

 Open the catalog to page 5
BACnet® MS/TP inputs (In-A, In-B)-6

BACnet® MS/TP, inputs (In-A, In-B) MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 Technical data Physical For installation in MULTICAL® 403, MULTICAL® 603 and MULTICAL® 803. Mechanical data Dimensions (L x W x D) Weight MULTICAL® Supply " Communication Protocol Baud rates [Auto] BACnet® vendor ID Object name Object Identifier Address range Data refresh rate BACnet® MS/TP, ASHRAE 135.1-2016, ISO 16484-5 9600 bit/s 19200 bits/s 38400 bits/s 57600 bits/s 76800 bits/s 115200 bits/s 546 (Kamstrup) Kamstrup HC-003-66 5 last digits of the serial number 1…254 Data from the meter to the module are refreshed...

 Open the catalog to page 6
BACnet® MS/TP inputs (In-A, In-B)-7

BACnet® MS/TP, inputs (In-A, In-B) MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 Ordering Description BACnet MS/TP, inputs (In-A, In-B) USB configuration cable for H/C-modules Infrared optical readout head w/USB A plug METERTOOL HCW Configuration XX Product type of module BACnet MS/TP, inputs (In-A, In-B) Communication settings Auto Datagram Default datagram Reserved

 Open the catalog to page 7
BACnet® MS/TP inputs (In-A, In-B)-8

BACnet® MS/TP, inputs (In-A, In-B) MULTICAL® 403 MULTICAL® 603 MULTICAL® 803 Displayed information Module information can be read by selecting “TECH loop” on the MULTICAL® display. Module in module slot 1: select menu 2-101 in “TECH loop” Module in module slot 2: select menu 2-201 in “TECH loop” Module in module slot 3: select menu 2-301 in “TECH loop” Module in module slot 4: select menu 2-401 in “TECH loop” Menu index 31 Information Display example Module type and configuration Module firmware and revision Module serial number

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.