Product Manual Kamoer Fluid Tech(Shanghai)Co., Ltd. Product name Micro peristaltic pump Product number Execution date Manufacturing unit Kamoer Fluid Tech(Shanghai) Co., Ltd.
Open the catalog to page 1Product Manual Name: Peristaltic Pump File Ref: CPBZ-KK300-01 Version number: A0 Effective Date: 2022-03-07 Product assembly drawing Motor model Add: Building 4, No. 79 Xiangjing Road, Songjiang District, Shanghai Tel:021-67742578 www.kamoer.com Make it smart to pump fl
Open the catalog to page 2Product Manual 3.1 Pump head material Name: Peristaltic Pump Pump head model Pump cover Synchronized disk Polymer Modified Materials Polymer Modified Materials Polymer Modified Materials Performance characteristics, typical applications Easy to operate, can quickly replace the pump tube; PET rotor, deep groove bearing drive long life, imported engineering plastic body; High precision, low noise, simple structure, maintenance-free; Two pipe clamp positions , which can accommodate 0.8~4.8mm inner diameter silicone tube and 0.8-3.2mm inner maximum speed of continuous operation is 400rpm; the flow...
Open the catalog to page 3Product Manual Name: Peristaltic Pump File Ref: CPBZ-KK300-01 Version number: A0 Effective Date: 2022-03-07 KK300 stepper motor product specification Product Size Mounting plate cutout Technical parameters Items Technical parameters Stepper motor Flow range Basic parameters Motor type Stepper driver method Weight Rated voltage Pump tube life Motor life Add: Building 4, No. 79 Xiangjing Road, Songjiang District, Shanghai Tel:021-67742578 www.kamoer.com
Open the catalog to page 4Product Manual Name: Peristaltic Pump Reference flow (unit: ml/min) Pump tube code Inner diameter Pump tube flow diameter (mm) Pump tube Silicone tube The above parameters are measured with pure water without pressure at 20 ° C room temperature and standard atmospheric pressure. Actually, according to different media and different outlet pressures, there will be a certain error in the flow rate. The data is for reference only, and can be customized according to customer needs. Reference noise value In a quiet room with an ambient noise of 35 dB, the product is 50 cm away from the noise tester...
Open the catalog to page 5Product Manual Name: Peristaltic Pump File Ref: CPBZ-KK300-01 Version number: A0 Effective Date: 2022-03-07 Motor parameters Specifications 1. Number of Phase 5. Holding torque Holding .Torque 0.66Nm Typ.( Two phsae on/rated current) Connector Pin Position vs. Lead Color PIN No. vs. Lead Wire Color Add: Building 4, No. 79 Xiangjing Road, Songjiang District, Shanghai Tel:021-67742578 www.kamoer.com Make it smart to pump
Open the catalog to page 6Product Manual Name: Peristaltic Pump Flow curve III、 Adapter hose Pump tube material Silicone Tube(S) Standards compliant Low adsorption, good temperature resistance, good chemical corrosion resistance, life expectancy over 200h Resistance to common chemicals, acid and alkali and oxidation resistance of more than 1000h Food Grade Certification (G B4806.11-2016 ) RoHS FDA Add: Building 4, No. 79 Xiangjing Road, Songjiang District, Shanghai Tel:021-67742578 www.kamoer.com Make it smart to pump fl
Open the catalog to page 7Product Manual Name: Peristaltic Pump Pipe clamp positioning KK300 can accommodate pump tubes with a wall thickness of 1.6mm and an inner diameter of Pipe clamp gear 1 Pipe clamp gear 2 must be used for pump tubes with inner diameters of 0.8 and 1.6 to prevent the pump tube from running away; must be used for pump tubes with inner diameters of 4 and 4.8 to prevent the flow from being reduced due to over - tightening of the pinch tube ; For pump tubes with inner diameters of 2.4 and 3.2, any gear can be used, and you can refer to Note 1 and Note 2 to choose which gear according to the actual situation;...
Open the catalog to page 8Pipe clamp switch Name: Peristaltic Pump File Ref: CPBZ-KK300-01 Version number: A0 Effective Date: 2022-03-07 Before switching the pipe diameter, turn off the pump and open the flip cover to fully open; Press the pipe clamp to the root by hand , keep the downward force to move the pipe clamp to the second track and release the force; If the pipe clamp does not slide to the second track, repeat the previous step to ensure that the pipe clamp enters the second track smoothly. Press point first track second track small pipe diameter to a large pipe diameter, the previous operation needs to be reversed...