Kambič d.o.o. offers a range of climatic chambers designed for precise temperature and relative humidity (Rh) control, suitable for material resistance testing, product conditioning, accelerated aging, and stress tests. These chambers provide superior stability and performance for metrology applications.

Key Features

  • Temperature range from -75 °C to +180 °C
  • Relative humidity control from 10% to 98% Rh
  • Extensive heat insulation on all chamber sides and doors
  • Exterior made of galvanized and powder-coated aluminized steel
  • 7-inch capacitive touch screen controller with Ethernet and USB connectivity
  • Internal air circulation fan with speed control
  • Water tank with level switch for humidity control
  • Heavy-duty closing mechanism with key lock and maintenance access
  • Full stainless-steel interior chamber
  • Observation window with LED illumination and full door heating
  • Adjustable stainless steel wire shelves included
  • Access port (Ø 50 mm) on the left side with plugs
  • Heavy-duty swivel wheels with brakes for mobility

Controller and Software

The chambers feature an advanced touch display controller with functions including:

  • Real-time display of set points and actual measured parameters
  • Program setup and editing
  • Remote control via KK-Tool PC software (included)
  • Graphical data visualization and full process history
  • Network status and time/date display

Models and Technical Specifications

Four models are available, differing mainly in internal volume and dimensions:

ModelInternal Volume (L)Temp. Range (°C)Heat Up Rate (°C/min)Cool Down Rate (°C/min)Temp. Stability (°C)Temp. Uniformity (°C)Rh Range (%)Rh Stability (%)Power (W)Water Reservoir (L)Weight (kg)
KK-190 CHULT~190-75 to +1802.22.4±0.5 @ -75 °C, ±0.1 @ 50 °C 50% Rh, ±0.1 @ 90 °C 90% Rh, ±0.2 @ 180 °C±1.2 @ -75 °C, ±0.5 @ 50 °C 50% Rh, ±0.5 @ 90 °C 90% Rh, ±2.0 @ 180 °C10–98±0.3 @ 50 °C 50% Rh, ±0.3 @ 90 °C 90% Rh630019.6440
KK-340 CHULT~340-75 to +1801.62.7±0.5 @ -75 °C, ±0.08 @ 50 °C 50% Rh, ±0.08 @ 90 °C 90% Rh, ±0.2 @ 180 °C±1.0 @ -75 °C, ±0.5 @ 50 °C 50% Rh, ±0.5 @ 90 °C 90% Rh, ±1.5 @ 180 °C10–98±0.3 @ 50 °C 50% Rh, ±0.3 @ 90 °C 90% Rh980019.6480
KK-500 CHULT~500-75 to +1803.62.2±0.8 @ -75 °C, ±0.1 @ 50 °C 50% Rh, ±0.1 @ 90 °C 90% Rh, ±0.2 @ 180 °C±1.0 @ -75 °C, ±0.5 @ 50 °C 50% Rh, ±0.5 @ 90 °C 90% Rh, ±1.5 @ 180 °C10–98±0.3 @ 50 °C 50% Rh, ±0.3 @ 90 °C 90% Rh1630035630
KK-1000 CHULT~1000-75 to +1803.52.1±0.8 @ -75 °C, ±0.1 @ 50 °C 50% Rh, ±0.1 @ 90 °C 90% Rh, ±0.2 @ 180 °C±1.0 @ -75 °C, ±0.5 @ 50 °C 50% Rh, ±0.5 @ 90 °C 90% Rh, ±1.5 @ 180 °C10–98±0.3 @ 50 °C 50% Rh, ±0.3 @ 90 °C 90% Rh1800045890

Note: All performance data are measured in controlled ambient conditions (22 °C ± 3 °C). Accessories may affect performance.

Control and Measurement

  • Temperature controlled by PID with PT-100 sensor
  • Relative humidity controlled via capacitive sensor with dry air purge option for extended range
  • Display and set resolution for temperature: 0.1 °C
  • Display resolution for Rh: 0.1%, set resolution: 1%

Accessories and Ordering Information

Available accessories include various wire and perforated shelves, access ports with plugs (Ø 50 mm and Ø 100 mm), automatic water feeding, extended Rh range via dry air purge, and evaluation reports (standard and accredited).

  • Climatic chambers KK-190, KK-340, KK-500, KK-1000 CHULT with respective part numbers
  • Shelves and access ports with specific part numbers
  • Optional automatic water feeding and extended humidity control
  • Evaluation reports for performance verification

Note: Accessories may influence chamber performance.

Summary of Critical Parameters and Best Practices

  • Ensure ambient temperature control around 22 °C ± 3 °C for optimal chamber performance
  • Use included KK-Tool software for remote monitoring and control to maintain process accuracy
  • Regular calibration and maintenance recommended to sustain temperature and humidity stability
  • Consider water consumption rates (~1.5 to 2.0 L/24h at 90 °C / 90% Rh) for operational planning
  • Utilize observation window and access ports for sample monitoring and sensor insertion without disturbing chamber environment
See more

Catalog excerpts

Ultra low temperature (- 75 °C …+ 180 °C)-1

CLIMATIC CHAMBERS (- 75 °C …+ 180 °C) Model: KK-190 CHULT KK-340 CHULT KK-500 CHULT KK-1000 CHULT  Temperature & Relative humidity-controlled test polygon  Material temperature & Rh resistance and product testing  Maintaining superior temperature & Rh stability  Sample conditioning prior to other tests  Data loggers and sensors calibration  World class metrology performance  Accelerated ageing Kambič d.o.o. Metliška cesta 16, SI-8333 Semič, Slovenia - EU, T: +386 (0)7 35 65 220, info©kambic.com, [email protected] www.kambic.com, ww

 Open the catalog to page 1
Ultra low temperature (- 75 °C …+ 180 °C)-2

Fan for internal air circulation with speed control 7'' capacitive touch screen controller with user friendly interface, advance settings options, Ethernet and USB communication ports 2 level over temp. protection: 1. 5°C over set point heating disabled 2. 10°C above max. temp mechanical shut off Extensive heat insulation shield on all chamber sides and doors Access port with both end plugs 050 mm (On left side) Door sealed with double soft profile silicone seal to ensure perfect tightness Adjustable stainless steel wire shelves galvanized and powder coated aluminized Heavy duty closing mechanism...

 Open the catalog to page 2
Ultra low temperature (- 75 °C …+ 180 °C)-3

Actual measured quantities in the chamber Network status icon Time Chamber •ROGRAM RUNNING Program progress; Controller with a 7-inch capacitive touch screen Virtual control panel - Complete remote control of the unit Function keys for viewing manipulation of the graph Real time data drawn to graph Full process history overview Kambic d.o.o. Metliska cesta 16, SI-8333 Semic, Slovenia - EU, T: +386 (0)7 35 65 220, info©kambic.com, [email protected] www.kambic.com,www.kambicmetrology.com

 Open the catalog to page 3
Ultra low temperature (- 75 °C …+ 180 °C)-4

- Ideal range A - Standard range B - Extended humidity range Kambic d.o.o. Metliska cesta 16, SI-8333 Semic, Slovenia - EU, T: +386 (0)7 35 65 220, info©kambic.com, [email protected] www.kambic.com,www.kambicmetrology.com

 Open the catalog to page 4
Ultra low temperature (- 75 °C …+ 180 °C)-5

External dimensions (WxHxD) [mm] Internal dimensions (WxHxD) [mm] Heat up rate [°C/min] (according to EN 60068-3-5) Cool down rate [°C/min] (according to EN 60068-3-5) Temperature display res [°C] Temperature set res. [°C] capacitive sensor/ dry air purge for capacitive sensor/ dry air purge for Rh display resolution [%] Rh set resolution [%] Temperature control Relative humidity control Power supply Wattage [W] Water reservoir capacity [L] Water consumption [L/24h] (operating at +90 °C / 90 %Rh) Observation window Access port [mm] Noise [dBA] @ 1 m distance Weight [kg] As standard 0 50 (left...

 Open the catalog to page 5
Ultra low temperature (- 75 °C …+ 180 °C)-6

KK-1000 CHULT External dimensions (WxHxD) [mm] Internal dimensions (WxHxD) [mm] Heat up rate [°C/min] (according to EN 60068-3-5) Cool down rate [°C/min] (according to EN 60068-3-5) Temperature display res [°C] Temperature set res. [°C] Rh display resolution [%] Rh set resolution [%] Temperature control Relative humidity control Power supply Wattage [W] Water reservoir capacity [L] Water consumption [L/24h] (operating at +90 °C / 90 %Rh) Observation window Access port [mm] Noise [dBA] @ 1 m distance Weight [kg] Dew point RH control via Rh capacitive sensor/ dry air purge for extended range 3x400V...

 Open the catalog to page 6
Ultra low temperature (- 75 °C …+ 180 °C)-7

Ordering information and accessories: *Accessories might affect performance! Kambic d.o.o. Metliska cesta 16, SI-8333 Semic, Slovenia - EU, T: +386 (0)7 35 65 220, info©kambic.com, [email protected] www.kambic.com,www.kambicmetrology.com

 Open the catalog to page 7
Ultra low temperature (- 75 °C …+ 180 °C)-8

Kambič d.o.o. Metliška cesta 16, SI-8333 Semič, Slovenia - EU, T: +386 (0)7 35 65 220, info©kambic.com, [email protected] www.kambic.com, www.kambicmetrology.co

 Open the catalog to page 8
Ultra low temperature (- 75 °C …+ 180 °C)-9

Kambič d.o.o. Metliška cesta 16, SI-8333 Semič, Slovenia - EU, T: +386 (0)7 35 65 220, info©kambic.com, [email protected] www.kambic.com, www.kambicmetrology.co

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.