1. Catalogs
  2. Kambic d.o.o.
  3. STABILITY TESTING CLIMATIC CHAMBER

STABILITY TESTING CLIMATIC CHAMBER
1 /6Pages

STABILITY TESTING CLIMATIC CHAMBER

STABILITY TESTING CLIMATIC CHAMBER
1 /6Pages

Catalog excerpts

STABILITY TESTING CLIMATIC CHAMBER-1

STABILITY TESTING CLIMATIC CHAMBER (+ 10 °C …+ 60 °C) (10 % Rh …90 % Rh) KK-830 CHS KK-1300 CHS Perfect tool for stability testing in pharmaceutical Industry • Following ICH guidelines • Calibrated at all ICH points o 25°C±2°C / 60% Rh±5% o 30°C±2°C / 65% Rh±5% o 40°C±2°C / 75% Rh±5% o 25°C±2°C / 40% Rh±5% o 30°C±2°C / 35% Rh±5% o 40°C±2°C / 20% Rh±5% GMP Qualification package available • Two different volumes available Kambic d.o.o. Metliska cesta 16; 8333 Semic ; Sloveni

 Open the catalog to page 1
STABILITY TESTING CLIMATIC CHAMBER-2

Access port for installation of independent sensors Fully stainless-steel chamber with 3 side double wall for superior air distribution above each shelve even at loaded chamber Extensive heat insulation shield on all chamber sides and doors All exterior in galvanized and powder coated steel RAL-7035 Controller with user friendly interface, advance settings options, RS-232, USB or Ethernet communication ports Soft profile silicone seal to ensure perfect tightness 2 level over temp. protection 1. 5 °C over set point heating disabled 2. 10°C above max. temp mechanical shut off Access port with both...

 Open the catalog to page 2
STABILITY TESTING CLIMATIC CHAMBER-3

Controller functions: Kambic d.o.o. Metliska cesta 16; 8333 Semic ; Slovenia - EU www.kambic.com [email protected]

 Open the catalog to page 3
STABILITY TESTING CLIMATIC CHAMBER-4

External dimensions (WxHxD) in mm Internal dimensions (WxHxD) in mm Volume (L) Temperature range (°C) Temperature display resolution (°C) Temperature set resolution (°C) Temperature stability (°C) Temperature uniformity (°C) Relative humidity range (%) Relative humidity display resolution (%) Relative humidity set resolution (%) Relative humidity stability Temperature control Relative humidity control Power supply Wattage (W) Interface Shelve Shelve capacity (kg) Max capacity (kg) Access port (mm) Noise (dBA) @ 1 m distance Weight (kg) Better than ±0.5°@ all ICH climatic points Better than ±0.5°@...

 Open the catalog to page 4
STABILITY TESTING CLIMATIC CHAMBER-5

Ordering information and accessories: Description Stability testing Climatic chamber KK-830 CHS Stability testing Climatic chamber KK-1300 CHS Shelve wire KK-830 CHS Shelve wire KK-1300 CHS Shelve perforated KK-830 CHS Shelve perforated KK-1300 CHS Access Port w. Plug Ø 40 mm right Access Port w. Plug Ø 50 mm right Access Port w. Plug Ø 90 mm right Observation window with illumination 370x420mm Automatic water feeding USB interface KK-Tool (Software Monitoring & History) Password protection Evaluation report GMP Qualification package (DQ, FAT, IQ, OQ) A4 Printer (continuous paper) Digital printing...

 Open the catalog to page 5
STABILITY TESTING CLIMATIC CHAMBER-6

Kambic d.o.o. Metliska cesta 16; 8333 Semic ; Slovenia - EU www.kambic.com [email protected]

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.