Catalog excerpts
Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 8 A Control with the following functions: - reversal of direction of rotation - overload shut-down - short circuit detection - dynamic brake To snap onto the DIN rail EN 50022 Unit width: 22,5 mm C€ Article number Operating data:_ Nominal voltage Supply voltage_ Control inputs_ Technical data: load circuit 28.03.2020 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH Strubelweg 14 D-73553 Alfdorf Tel.: +49 7172 93711 0 info@kaleia.com
Open the catalog to page 1Housing, terminal, printed circuit board _UL94-HB The module MAXI-MW-8-30 is a two-quadrant DC motor control for use in an industrial environment. It guarantees the switching on and off of motors. The motor stops always with dynamic braking. | Typical applications: 28.03.2020 KL - Errors and technical modification subject to change. All rights reserved. © KALEJA GmbH
Open the catalog to page 2| Continuous load current / total current | Overload/over temperature switch off When operating one motor, the continuous load current The device has an integrated overload and over specified in the technical data applies. temperature detection. If an event occurs, the motor will be switched off. After cooling down of the device When operating 2 motors the total current depends on the motor restarts automatically. various factors that must be determined depending on the application. E.g.: ambient temperature, duty cycle, installation situation. The maximum specified total current must not...
Open the catalog to page 3| Safety notes Maximum operational data The maximum operating data may not be exceeded. Installation The installation and start-up must be performed by specialist personnel exclusively. All affected components must be disconnected from the mains. Start-up For the first start-up, the motor should be operated without load. Risk of death Do not touch live parts after switching on! The assembly must be operated exclusively on safety extra-low voltage. With operation on extra-low voltage (e.g. via autotransformer), death or injury can occur. Fire protection The assembly must be installed in a...
Open the catalog to page 4All KALEJA GmbH catalogs and technical brochures
-
M5-2QB-12-48 06.38.007
9 Pages
-
M5-BL-12-48 06.38.001
9 Pages
-
M-MWS-6-30
1 Pages
-
M-MRI-3-30
2 Pages
-
M-BL-5-30
2 Pages
-
M-MZ-4-30
2 Pages
-
Maxi-1Q-4-30
2 Pages
-
M-1Q-6-30
2 Pages
-
M-4Q-6-30
2 Pages
-
M-2Q-6-30
2 Pages
-
MAXI-GMF-8-30
4 Pages
-
M-S-6-30
2 Pages
-
Maxi-S-4-30
2 Pages
-
M2-CMR-5-30 06.34.018
6 Pages
-
Mini-SO-50-30
1 Pages
-
Mini-OM-50-30
1 Pages
-
Mini-OM-08-30
1 Pages
-
M2-MR-5-30
6 Pages
-
02.01.115_Mini-OM-25-30
1 Pages
-
06.04.202
4 Pages
-
06.04.201_Maxi-M-8-30
4 Pages
-
M2-3DR-5-30
8 Pages
-
M2-MWS-6-30
7 Pages
-
M2-MWI-6-30
7 Pages
-
M3-2QB-5-12
7 Pages
-
M3-4Q-5-30
7 Pages
-
Maxi-IMD-5-60
3 Pages
-
Maxi-IM-5-60
3 Pages
-
MB-12
1 Pages
-
Midi-OM-100-30
1 Pages
-
USV-S-9-B
1 Pages
-
USV-S-25-S
1 Pages
-
M3-2QB-5-30
7 Pages
-
M2-MWT-6-30
7 Pages
-
06.34.008
2 Pages
-
06.04.032
2 Pages
-
06.34.006
7 Pages
-
06.34.002
6 Pages
-
01.01.212
1 Pages
-
01.01.213
1 Pages
-
02.01.104
1 Pages
-
02.01.116
1 Pages
-
02.01.117
1 Pages
-
02.01.130
1 Pages
-
02.03.226
1 Pages
-
02.06.201
1 Pages
-
04.08.001
1 Pages
-
06.04.007
2 Pages
-
06.04.008
2 Pages
-
06.04.012
1 Pages
-
06.04.014
1 Pages
-
06.04.016
2 Pages
-
06.04.019
2 Pages
-
06.04.021
2 Pages
-
06.04.025
2 Pages
-
06.04.031
2 Pages
-
06.04.039
2 Pages
-
06.04.046
2 Pages
-
06.04.048
2 Pages
-
06.04.049
2 Pages
-
06.04.051
2 Pages
-
06.04.054
2 Pages
-
06.04.056
2 Pages
-
06.04.059
2 Pages
-
06.04.066
2 Pages
-
06.04.075
2 Pages
-
06.04.078
1 Pages
-
06.04.083
2 Pages
-
06.04.085
2 Pages
-
06.04.093
2 Pages
-
06.34.001
5 Pages
-
01.01.012
1 Pages
-
01.01.011E
1 Pages
-
01.01.007
1 Pages