video corpo

M3-2QB-5-12
7Pages

{{requestButtons}}

Catalog excerpts

M3-2QB-5-12 - 1

Industrial motor controller for brushed DC motors 12 VDC Design for output currents up to 5 A Control with the following functions: - reversal of direction of rotation - rotational speed control (external) - current limitation control (external) - overcurrent limitation / Overcurrent shutdown - adjustable start ramp - adjustable stop ramp - adjustable current monitoring delay - short circuit detection - dynamic brake To snap onto the DIN rail EN 50022 VCC (14)0—1 VCC (16)0— disable brake (11)0— PWM 100% (12)0— current mode (4) O— right (2) O—. left (1)0— 27.11.2018 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH Strubelweg 14 D-73553 Alfdorf, Germany Phone: +49 7172 93711 0 info@kaleja.com

Open the catalog to page 1
M3-2QB-5-12 - 2

Housing, terminals, printed circuit board _UL94V-0 After applying supply voltage, the module M3-2QB-5-12 is ready for operation when the start up time has elapsed. The M3-2QB-5-12 module is a multi-functional motor controller for use in industrial environments. It ensures the switching on and off, as well as the controlled driving of motors. The motor's direction of rotation can be set via a digital input. An internal trimmer can be used to set the maximum speed. By means of an analog input the speed can be set between 0 to maximum speed. The dynamic brake can be deactivated over a digital...

Open the catalog to page 2
M3-2QB-5-12 - 3

Datasheet M3-2QB-5-12 06.34.006 Typical application: Standard 27.11.2018 KL - Errors and technical modification subject to change. All rights reserved. © KALEJA GmbH

Open the catalog to page 3
M3-2QB-5-12 - 4

After setting any direction of rotation direction, the After clearing the rotation direction, the module ramps module ramps up the speed until the set value is the speed down until stop. The gradient of the stop ramp reached. The gradient of the start ramp can be adjusted can be adjusted via trimmer TR1. via trimmer TR3. After the stop ramp the module stop behaviour is as adjusted over digital input (11). See function: dynamic brake. 27.11.2018 KL - Errors and technical modification subject to change. All rights reserved

Open the catalog to page 4
M3-2QB-5-12 - 5

27.11.2018 KL - Errors and technical modification subject to change. All rights reserved. © KALEJA GmbH

Open the catalog to page 5
M3-2QB-5-12 - 6

Device status Display elements The module status is displayed via the LEDs on the module front plate. Module errors are displayed as flashing sequences. The end of the sequence is indicated by a pause of 1 second. The number of flashes indicates the error number. If the module is assembled with a minimum clearance of 10 mm on both sides these derating The curves are valid for 100% on-time 27.11.2018 KL - Errors and technical modification subject to change. All rights reserved. © KALEJA GmbH

Open the catalog to page 6
M3-2QB-5-12 - 7

Maximum operational data The maximum operating data must not be exceeded. Installation The installation and start-up must be performed by specialist personnel exclusively. All affected components must be disconnected from the mains. Start-up For the first start-up, the motor should be operated without load. Risk of death Do not touch live parts after switching on! The assembly must be operated exclusively on safety extra-low voltage. With operation on extra-low voltage (e.g. via autotransformer), death or injury can occur. Fire protection The assembly must be installed in a switch cabinet,...

Open the catalog to page 7

All KALEJA GmbH catalogs and technical brochures

  1. M-MWS-6-30

    1 Pages

  2. M-MRI-3-30

    2 Pages

  3. M-BL-5-30

    2 Pages

  4. M-MZ-4-30

    2 Pages

  5. Maxi-1Q-4-30

    2 Pages

  6. M-1Q-6-30

    2 Pages

  7. M-4Q-6-30

    2 Pages

  8. M-2Q-6-30

    2 Pages

  9. M-S-6-30

    2 Pages

  10. Maxi-S-4-30

    2 Pages

  11. MAXI-MW-8-30

    4 Pages

  12. M2-MR-5-30

    6 Pages

  13. 06.04.202

    4 Pages

  14. M2-3DR-5-30

    8 Pages

  15. M2-MWS-6-30

    7 Pages

  16. M2-MWI-6-30

    7 Pages

  17. M3-4Q-5-30

    7 Pages

  18. Maxi-IM-5-60

    3 Pages

  19. MB-12

    1 Pages

  20. USV-S-9-B

    1 Pages

  21. USV-S-25-S

    1 Pages

  22. M3-2QB-5-30

    7 Pages

  23. M2-MWT-6-30

    7 Pages

  24. 06.34.008

    2 Pages

  25. 06.04.032

    2 Pages

  26. 06.34.006

    7 Pages

  27. 06.34.002

    6 Pages

  28. 01.01.212

    1 Pages

  29. 01.01.213

    1 Pages

  30. 02.01.104

    1 Pages

  31. 02.01.116

    1 Pages

  32. 02.01.117

    1 Pages

  33. 02.01.130

    1 Pages

  34. 02.03.226

    1 Pages

  35. 02.06.201

    1 Pages

  36. 04.08.001

    1 Pages

  37. 06.04.007

    2 Pages

  38. 06.04.008

    2 Pages

  39. 06.04.012

    1 Pages

  40. 06.04.014

    1 Pages

  41. 06.04.016

    2 Pages

  42. 06.04.019

    2 Pages

  43. 06.04.021

    2 Pages

  44. 06.04.025

    2 Pages

  45. 06.04.031

    2 Pages

  46. 06.04.039

    2 Pages

  47. 06.04.046

    2 Pages

  48. 06.04.048

    2 Pages

  49. 06.04.049

    2 Pages

  50. 06.04.051

    2 Pages

  51. 06.04.054

    2 Pages

  52. 06.04.056

    2 Pages

  53. 06.04.059

    2 Pages

  54. 06.04.066

    2 Pages

  55. 06.04.075

    2 Pages

  56. 06.04.078

    1 Pages

  57. 06.04.083

    2 Pages

  58. 06.04.085

    2 Pages

  59. 06.04.093

    2 Pages

  60. 06.34.001

    5 Pages

  61. 01.01.012

    1 Pages

  62. 01.01.011E

    1 Pages

  63. 01.01.007

    1 Pages