video corpo

M2-MWT-6-30
1 /7Pages

M2-MWT-6-30

M2-MWT-6-30
1 /7Pages

Catalog excerpts

M2-MWT-6-30-1

15.02.2018 KL - Errors and technical modification subject to change. All rights reserved. KALEJA GmbH Strubelweg 14 D-73553 Alfdorf, Germany Phone: +49 7172 93711 0 [email protected]

 Open the catalog to page 1
M2-MWT-6-30-2

Housing, terminals, printed circuit board _UL94V-0 After applying supply voltage, the module is ready for operation when the start up time has elapsed. The module is a two quadrant motor control for use in industrial environments. It ensures the switching on and off, as well as the controlled driving of motors. Over a DIP switch and two internal trimmer the motor current limit value for the overcurrent shutdown is for each direction of rotation adjustable. The continuous load current form the module is 6A. A digital output reports if the module is in overcurrent shutdown mode. Current monitoring...

 Open the catalog to page 2
M2-MWT-6-30-3

Datasheet M2-MWT-6-30 06.34.007 Typical application: Standard 15.02.2018 KL - Errors and technical modification subject to change. All rights reserved. © KALEJA GmbH

 Open the catalog to page 3
M2-MWT-6-30-4

15.02.2018 KL - Errors and technical modification subject to change. All rights reserved.

 Open the catalog to page 4
M2-MWT-6-30-5

The module is internally protected with an overload shutdown. In case of rising of the motor current over the rated continuous load current the module switches of with a thermal safety function. After the shutdown the module is locked for a cooldown phase which is managed by the module. | Function: dynamic brake | Function: overload / short circuit detection The motor always stops with dynamic brake while When the module detects overload or short circuit on normal operation. the motor output, the motor switches off without dynamic braking. The motor can be restarted by means of a reset...

 Open the catalog to page 5
M2-MWT-6-30-6

Datasheet M2-MWT-6-30 06.34.007 Temperature derating At 100% duty cycle and aligned modules with 10mm spacing the following diagram is valid. Dimensional drawing 15.02.2018 KL - Errors and technical modification subject to change. All rights reserved. © KALEJA GmbH

 Open the catalog to page 6
M2-MWT-6-30-7

Maximum operational data The maximum operating data must not be exceeded. Installation The installation and start-up must be performed by specialist personnel exclusively. All affected components must be disconnected from the mains. Start-up For the first start-up, the motor should be operated without load. Risk of death Do not touch live parts after switching on! The assembly must be operated exclusively on safety extra-low voltage. With operation on extra-low voltage (e.g. via autotransformer), death or injury can occur. Fire protection The assembly must be installed in a switch cabinet, which...

 Open the catalog to page 7

All KALEJA GmbH catalogs and technical brochures

  1. M-MWS-6-30

    1  Page

  2. M-MRI-3-30

    2  Pages

  3. M-BL-5-30

    2  Pages

  4. M-MZ-4-30

    2  Pages

  5. Maxi-1Q-4-30

    2  Pages

  6. M-1Q-6-30

    2  Pages

  7. M-4Q-6-30

    2  Pages

  8. M-2Q-6-30

    2  Pages

  9. MAXI-GMF-8-30

    4  Pages

  10. M-S-6-30

    2  Pages

  11. Maxi-S-4-30

    2  Pages

  12. MAXI-MW-8-30

    4  Pages

  13. M2-MR-5-30

    6  Pages

  14. 06.04.202

    4  Pages

  15. M3-4Q-5-30

    7  Pages

  16. M3-2QB-5-12

    7  Pages

  17. M2-MWI-6-30

    7  Pages

  18. M2-MWS-6-30

    7  Pages

  19. M2-3DR-5-30

    8  Pages

  20. Maxi-IMD-5-60

    3  Pages

  21. Maxi-IM-5-60

    3  Pages

  22. MB-12

    1  Page

  23. USV-S-9-B

    1  Page

  24. USV-S-25-S

    1  Page

  25. 06.04.032

    2  Pages

  26. M3-2QB-5-30

    7  Pages

  27. 06.34.008

    2  Pages

  28. 06.34.006

    7  Pages

  29. 06.34.002

    6  Pages

  30. 01.01.212

    1  Page

  31. 01.01.213

    1  Page

  32. 02.01.104

    1  Page

  33. 02.01.116

    1  Page

  34. 02.01.117

    1  Page

  35. 02.01.130

    1  Page

  36. 02.03.226

    1  Page

  37. 02.06.201

    1  Page

  38. 04.08.001

    1  Page

  39. 06.04.007

    2  Pages

  40. 06.04.008

    2  Pages

  41. 06.04.012

    1  Page

  42. 06.04.014

    1  Page

  43. 06.04.016

    2  Pages

  44. 06.04.019

    2  Pages

  45. 06.04.021

    2  Pages

  46. 06.04.025

    2  Pages

  47. 06.04.031

    2  Pages

  48. 06.04.039

    2  Pages

  49. 06.04.046

    2  Pages

  50. 06.04.048

    2  Pages

  51. 06.04.049

    2  Pages

  52. 06.04.051

    2  Pages

  53. 06.04.054

    2  Pages

  54. 06.04.056

    2  Pages

  55. 06.04.059

    2  Pages

  56. 06.04.066

    2  Pages

  57. 06.04.075

    2  Pages

  58. 06.04.078

    1  Page

  59. 06.04.083

    2  Pages

  60. 06.04.085

    2  Pages

  61. 06.04.093

    2  Pages

  62. 06.34.001

    5  Pages

  63. 01.01.012

    1  Page

  64. 01.01.011E

    1  Page

  65. 01.01.007

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.