Hebefix plus

Hebefix plus

Hebefix plus

Product catalog summary
Performance and Application: The Hebefix plus lifting station is designed for easy installation to dispose of faeces-free wastewater both above and below the local back pressure level. It is suitable for use in commercial pre-wall systems and can be installed under washbasins or in other locations. It connects to various grey water producers like washbasins, showers, and washing machines. The system pumps grey water to the nearest downpipe through a small-dimensioned pressure pipe and is ideal for additional bathrooms or kitchens during renovations. It includes an alarm system for acoustic failure messages and complies with German European standard EN 12050.
Specifications: The Hebefix plus is equipped with a submersible pump (U3 variant) that operates automatically. It requires a minimum flow velocity of 0.7 m/s in the delivery piping as per EN 12056. The unit is pressure-tight, easy to maintain, and includes an integrated control with an alarm. It features a high-quality ABS plastic tank.
Electrical Data: The Hebefix plus operates on a 1-phase 230V current with a motor rating of 0.32 kW and a full load current of 1.4 amperes. It includes a safety plug and motor protection in the winding.
Installation and Mounting Instructions: The Hebefix plus can be combined with commercially available pre-wall systems. Proper ventilation is necessary to prevent moisture buildup. The system includes all necessary components and can be accessed through an inspection opening for maintenance. The activated carbon filter in the venting system can be changed by removing the ventilation grille.
Technical Data: The unit includes a U3-type submersible pump with a 10 mm free passage and EIP technology. It features a vertical, single-stage pump with IP 68 enclosure and automatic float switch for level control. The materials used include stainless steel for the motor housing and shaft, and plastic for the tank and pump housing.
Scope of Supply: The Hebefix plus comes ready-to-connect with a cable and plug, including collars, outlet elbow, swing-type check valve, transition nipple, ventilation insert, activated carbon filter, clamps, and fastening material.
See more

Catalog excerpts

Hebefix plus-1

Drainage lifting station Hebefix plus Application The Hebefix plus lifting station is an easily installed appliance for disposing of faeces-free wastewater above and below the local back pressure level. Thanks to the small depth of its tank, it can be used in all commercial pre-wall systems. Its attractive design and intelligent technology also allow it to be fitted directly under a washbasin or in any other location. All grey water producers such as washbasins, showers, bathtubs, sinks, washing machines, etc. can be connected. The grey water is pumped to the nearest downpipe through a small-dimensioned pressure pipe (left or right side). Hebefix plus can be used wherever an additional bathroom or kitchen is required as part of renovation or conversion work. Used in bathrooms, this appliance is the ideal complement to our WCfix 260 V which, according to the German European standard EN 12050-3, is unsuitable for connection to a bathtub or washing machine. For acoustic failure message, Hebefix plus contains an alarm system with a reed contact switch. The unit is supplied with a submersible pump mounted (U3 variant) which is ready to be plugged to a safety socket and operates fully automatically as soon as wastewater starts to flow in. When installed in bathrooms and shower rooms, the corresponding German VDE regulations must be observed. Hebefix plus (pump included in the scope of supply) A sufficiently large inspection opening has to be provided for installation and servicing work (accessory). The unit is in conformity with the specifications of the German Eurpean standard EN 12050. Unit for pre-wall installation or direct connection Quiet Ready to connect Easy to maintain Pressure-tight Integrated control with alarm High-quality plastic tank (ABS) 4 27945-00 We reserve the right to change specifications without notice. Pump performance is subject to ISO 9906 tolerances The minimum flow velocity in the delivery piping must be 0.7 m/s according to EN 12056. This data is represented in the performance curve as a limit of application D 130–1.0–1205

 Open the catalog to page 1
Hebefix plus-2

Drainage lifting station Hebefix plus Hebefix plus Type Height x Width x Depth Cable Weight approx. Code Installation kit for the inspection opening (flexibly adjustable to the tiles, 500 x 500 mm min.) JP41075 Hebefix plus_Flow rate Q [m3/h]_65_5S_5Q_4JD_3JD_]S Electrical data Type Type of current Voltage Motor rating kW RPM F.L.C. Motor protection Plug Hebefix plus 1-phase_1/N/PE-230 0.32 0.20 2720_L4_in the winding Safety- Mounting arrangement Vertical pressure pipe with swing-type check valve and loop to be passed above the locally defined back pressure Inspection opening

 Open the catalog to page 2
Hebefix plus-3

Drainage lifting station Hebefix plus Mounting instructions ventilation insert, ventilation grille shim disc HT pipe DN 50 Hebefix plus can be combined with all commercially available pre-wall systems. The distances shown between the elements must be observed. Rails mounted on the floor for the alignment of several elements can be placed underneath the tank to save space. A ventilation system is imperative for operation. The installation method shown prevents moisture from developing behind the pre-wall. The Hebefix plus comes complete with all the special components required. Ventilation pipe...

 Open the catalog to page 3
Hebefix plus-4

Drainage disposal unit Hebefix plus Technical data Type Tank complete with ready installed U3-type submersible pump with 10 mm free passage and hydraulics in EIP technology with open 5-impeller wheel, pressure drain bend of the tank made of elastomer with connection socket for pressure pipe (made of PVC, PP or PE) DN 32 with a diam. of 40 mm and 1 x 40 mm diameter. 4 x Inlet connections - diam. 50 mm. Connection to the appliance's nozzles with elastic connection collars. Pump Vertical, single stage, completely submersible, IP 68 enclosure type, insulation class B, motor thermostat for safety...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.