1. Catalogs
  2. Jorc Industrial
  3. Air Saving products

Air Saving products
1 /12Pages

Air Saving products

Air Saving products
1 /12Pages

Catalog excerpts

Air Saving products-1

SYSTEM AIR-SAVER ULTRASONIC LEAK DETECTION

 Open the catalog to page 1
Air Saving products-3

Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR Condensate Management Specialist COMPRESSED AIR SAVING PRODUCTS

 Open the catalog to page 3
Air Saving products-4

Information provided herewith is believed to be accurate and reliable. However, no responsibility is assumed for its use or for any infringement of patents or rights of others, which may result from its use. In addition, JORC reserves the right to revise information without notice and without incurring any obligation.

 Open the catalog to page 4
Air Saving products-5

Air leaks are a concern for anyone operating a compressed air system. The average plant with no formal leak management program will have air leaks that waste up to 30 percent of the total air capacity. Leaks will cause compressors to run at full load for longer periods of time. The compressors will not only use more energy but, may also need additional maintenance due to the increased loads. Leaks can give the false impression that additional compressors are required to meet the demand for compressed air. COMMON LEAK POINTS • Quick connections fittings have o-rings to seal the hose connections....

 Open the catalog to page 5
Air Saving products-6

AIR-SAVER G1 Compressed air energy saver PRODUCT FEATURES A typical compressed air system will have air loss through pipe work connections, leaking float type drains etc. At the end of the daily working shift the Air-Saver will shut the air tank off from the rest of the system. The content of compressed air within the air tank will be saved rather than lost through pipe work leakages. The Air-Saver is installed on the air outlet of the air tank. The Air-Saver will automatically OPEN just prior to the working shift begins and CLOSES just after the working shift is over. COMMERCIAL BENEFITS • Microprocessor...

 Open the catalog to page 6
Air Saving products-7

PRODUCT SPECIFICATIONS Supply voltage Power consumption Opening / Closing duration Operating temperature Valve Connection Pressure range Indicators 115V or 240 VAC/DC 50/60Hz 7W during cycle rotation 30 sec. / 90° 0°C to +60°C Nickel plated brass with stainless steel ball 1" BSP or NPT 0 - 16 bar (230 psi maximum) LCD indicating program and current time PRODUCT FEATURES Built-in quartz controlled timer. Large LCD display. Current time display. Reset function. Remote control option. 1” st/st rotation ball. AIR-SAVER G1 TECHNICAL SPECIFICATIONS

 Open the catalog to page 7
Air Saving products-8

AIR-SAVER G2 Compressed air energy saver PRODUCT FEATURES A typical compressed air system will have air loss through pipe work connections, leaking float type drains etc. At the end of the daily working shift the Air-Saver will shut the air tank off from the rest of the system. The content of compressed air within the air tank will be saved rather than lost through pipe work leakages. The Air-Saver is installed on the air outlet of the air tank. The Air-Saver will automatically OPEN just prior to the working shift begins and CLOSES just after the working shift is over. COMMERCIAL BENEFITS • •...

 Open the catalog to page 8
Air Saving products-9

AIR-SAVER G2 TECHNICAL SPECIFICATIONS PRODUCT SPECIFICATIONS Supply Voltage Power consumption Opening / Closing duration 2” Maximum Ambient temperature Maximum medium temperature Pressure range Valve Manual override Environmental protection Timer display 230VAC or 115VAC 50/60 Hz 7W during cycle rotation 105 sec. / 90° 50°C 100°C 0 to 16 bar (230 psi maximum) 2” connections, brass/nickel plated Yes IP54 24 hours PRODUCT FEATURES Built-in quartz controlled timer. Large LCD display. Current time display. Reset function. Remote control option. 2” st/st rotation ball

 Open the catalog to page 9
Air Saving products-10

LOCATOR Ultrasonic air leak detector PRODUCT FEATURES What produces ultrasound in a leak? When a gas passes through a restricted orifice under pressure, it is going from a pressurised laminar flow to low pressure turbulent flow. The turbulence generates a broad spectrum of sound. There are ultrasonic components in the sound and since the ultrasound will be the loudest by the leak site, the detection of these signals is usually quite simple. COMMERCIAL BENEFITS • • • • • Ultrasonic leak detection to save money SMT/solid state hybrid heterodyne receiver Supplied in case, complete with headset and...

 Open the catalog to page 10
Air Saving products-11

PRODUCT SPECIFICATIONS Construction Circuitry Frequency Response Indicator Sensitivity Selection Power Low battery indicator Headset Transmitter Response time Ambient operating temp. Relative humidity Hand held ABS pistol type ultrasonic processor Stainless steel sensor enclosures SMT/Solid state hybrid heterodyne receiver 20-100 kHz (centered at 28-42 kHz) 10 segment leak indication LED bar 8 sensitivity positions 9 volt alkaline battery LED Noise isolating type: double headset wired monophonic Impedance: 16 ohms. Over 23 dB noise attenuation. Meets or exceeds ANSI specifications and OSHA standards....

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.