Catalog excerpts
LC LC Characteristics Low pressure cartridge for diverter valves Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 25/85 mbar (influenced by customers valve body) PA6.6 GF30 0.5…4.5 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Tyco AMP MODU IV IP40 Diverter Valves Technical Data Pipe connection Switch-over time Motor Coil resistance Supply voltage Chopper current level Duty cycle clip 2s (depends on users sequence) bipolar stepper motor 34 Ohm 24V 200mA/coil 30% within 5 minutes Circuit diagram pull in (step I to IV, I to IV, etc.) push out (step IV to I, IV to I etc.) Mating plug: AMP connector ■ housing 0-1740209-6 ■ contact 2-167301-1 Saia motors
Open the catalog to page 1Pressure Drop [mbar] Ball in lower position Ball in upper position Ball in lower position Ball in upper position Diverter Valves Pressure Drop [mbar] Flow curve Saia motors
Open the catalog to page 2SC SC Characteristics Standard cartridge for diverter valves Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 65/110 mbar (influenced by customers valve body) PA6.6 GF30 0.5…3.0 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Tyco AMP MODU IV IP40 Diverter Valves Technical Data Pipe connection Switch-over time Motor Coil resistance Supply voltage Duty cycle clip 2s (e.g. 10steps/50Hz, 243steps/300Hz,...
Open the catalog to page 3diameter valve body + 0,1 0 delivery position Performance Chart Flow curve 180 Ball in lower position Ball in upper position Diverter Valves Pressure Drop [mbar] Saia motors
Open the catalog to page 4LV LV Characteristics Low pressure drop diverter valve Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 25/85 mbar PA6.6 GF30 0.5…4.5 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Tyco AMP MODU IV IP40 Technical Data Pipe connection Switch-over time Motor Coil resistance Supply voltage Chopper current level Duty cycle clip 2s (depends on users sequence) bipolar stepper motor 34 Ohm 24V 200mA/coil 30% within...
Open the catalog to page 5Ball in lower position Ball in upper position Pressure Drop [mbar] Performance Chart Pressure Drop [mbar] Diverter Valves Ball in lower position Ball in upper position Saia motors
Open the catalog to page 6SV SV Characteristics Standard diverter valve Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 65/110 mbar PA6.6 GF30 0.5…3.0 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Tyco AMP MODU IV IP40 Diverter Valves Technical Data Pipe connection Switch-over time Motor Coil resistance Supply voltage Duty cycle Circuit diagram pull in (step I to IV, I to IV, etc.) push out (step IV to I, IV to I etc.) Mating plug:...
Open the catalog to page 7Diverter Valves Saia motors
Open the catalog to page 8SV Performance Chart Flow curve 180 Ball in lower position Ball in upper position Pressure Drop [mbar] Diverter Valves Pressure Drop [mbar] Ball in lower position Ball in upper position Saia motors
Open the catalog to page 9LE LE Characteristics Low pressure drop electric diverter valve Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 25/85 mbar PA6.6 GF30 0.5…3.0 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Lumberg RAST2,5 3510 P04 K20 IP00 (due to electr. connector) Technical Data clip 2s *) included 24V *) 10% movement within 5 minutes ground / open (via open collector output) (customisation e.g. PWM, 0-10V on request)...
Open the catalog to page 10Pressure Drop [mbar] Ball in lower position Ball in upper position Performance Chart Pressure Drop [mbar] Diverter Valves Ball in lower position Ball in upper position Saia motors
Open the catalog to page 11SE SE Characteristics Standard electric diverter valve Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 65/110 mbar PA6.6 GF30 0.5…3.0 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Lumberg RAST2,5 3510 P04 K20 IP00 (due to electr. connector) Technical Data clip 2s *) included 24V *) 10% movement within 5 minutes ground / open (via open collector output) (customisation e.g. PWM, 0-10V on request) Diverter...
Open the catalog to page 12Performance Chart Flow curve 180 Ball in lower position Ball in upper position Pressure Drop [mbar] Diverter Valves Saia motors
Open the catalog to page 13All Johnson Electric catalogs and technical brochures
-
BTA® Size 6EV
2 Pages
-
VersaSortTM Modules
2 Pages
-
Ledex® Rotary Solenoids
2 Pages
-
TrueDrive™ Motorized Rollers
4 Pages
-
Solligence™ Actuators
3 Pages
-
Solutions by industry
26 Pages
-
Automotive Products Group
10 Pages
-
Industry Products Group
11 Pages
-
SMART METERING
14 Pages
-
Ultimag® Rotary Actuators
3 Pages
-
Ledex® Tubular Solenoids
37 Pages
-
Soft Shift® Solenoids
3 Pages
-
Low Profile Solenoids
3 Pages
-
Nanomotion Motion Systems
9 Pages
-
Compact Lite Window Lift Drive
12 Pages
-
Nanomotion-Motors
8 Pages
-
Compact AC Starters
4 Pages
-
Shaded Pole Motors
32 Pages
-
Saia Motors
157 Pages
-
Secure Flex
1 Pages
-
Prepayment Meter Valves
2 Pages
-
Smart Meter Valves
2 Pages
-
Drive Electronics
3 Pages
-
Standard Rotary Stepper Motors
38 Pages
-
Standard Linear Stepper Motors
17 Pages
-
Rotary Synchronous Motors
91 Pages
-
Universal AC Motors
48 Pages
-
vd751(0)-101
2 Pages
-
hc315xlg-101
2 Pages
-
kc315msg-101
2 Pages
-
HC415LG-101
2 Pages
-
mp2340-101
2 Pages
-
hc675g-101
2 Pages
-
hc658ulg-101
2 Pages
-
NF123g-101
2 Pages
-
mo25wj-101
2 Pages
-
nf243g-103
2 Pages
-
hF658ulg-105
2 Pages
-
HC675XLLG-101
2 Pages
-
hc675lg-102
2 Pages
-
mo25mm-102
2 Pages
Archived catalogs
-
Specialized switching solution
24 Pages
-
TH-contact panel mounted push button
112 Pages
-
Burgess Switches
80 Pages
-
saia microswitches
54 Pages
-
Saia-Motors
218 Pages
-
Johnsonelectric brochure
22 Pages
-
LEDEX DC Solenoids Metric
228 Pages
-
LEDEX DC Solenoids Imperial
228 Pages
-
Dormeyer AC Solenoids Imperial
52 Pages
-
Johnson DC Motors
231 Pages
-
Synchronous_Motors
2 Pages