video corpo

Diverter Valve
1 /13Pages

Diverter Valve

Diverter Valve
1 /13Pages

Catalog excerpts

Diverter Valve-1

LC LC Characteristics Low pressure cartridge for diverter valves Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 25/85 mbar (influenced by customers valve body) PA6.6 GF30 0.5…4.5 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Tyco AMP MODU IV IP40 Diverter Valves Technical Data Pipe connection Switch-over time Motor Coil resistance Supply voltage Chopper current level Duty cycle clip 2s (depends on users sequence) bipolar stepper motor 34 Ohm 24V 200mA/coil 30% within 5 minutes Circuit diagram pull in (step I to IV, I to IV, etc.) push out (step IV to I, IV to I etc.) Mating plug: AMP connector ■  housing 0-1740209-6 ■  contact 2-167301-1 Saia motors

 Open the catalog to page 1
Diverter Valve-2

Pressure Drop [mbar] Ball in lower position Ball in upper position Ball in lower position Ball in upper position Diverter Valves Pressure Drop [mbar] Flow curve Saia motors

 Open the catalog to page 2
Diverter Valve-3

SC SC Characteristics Standard cartridge for diverter valves Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 65/110 mbar (influenced by customers valve body) PA6.6 GF30 0.5…3.0 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Tyco AMP MODU IV IP40 Diverter Valves Technical Data Pipe connection Switch-over time Motor Coil resistance Supply voltage Duty cycle clip 2s (e.g. 10steps/50Hz, 243steps/300Hz, 50steps/50Hz)...

 Open the catalog to page 3
Diverter Valve-4

diameter valve body + 0,1 0 delivery position Performance Chart Flow curve 180 Ball in lower position Ball in upper position Diverter Valves Pressure Drop [mbar] Saia motors

 Open the catalog to page 4
Diverter Valve-5

LV LV Characteristics Low pressure drop diverter valve Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 25/85 mbar PA6.6 GF30 0.5…4.5 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Tyco AMP MODU IV IP40 Technical Data Pipe connection Switch-over time Motor Coil resistance Supply voltage Chopper current level Duty cycle clip 2s (depends on users sequence) bipolar stepper motor 34 Ohm 24V 200mA/coil 30% within 5...

 Open the catalog to page 5
Diverter Valve-6

Ball in lower position Ball in upper position Pressure Drop [mbar] Performance Chart Pressure Drop [mbar] Diverter Valves Ball in lower position Ball in upper position Saia motors

 Open the catalog to page 6
Diverter Valve-7

SV SV Characteristics Standard diverter valve Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 65/110 mbar PA6.6 GF30 0.5…3.0 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Tyco AMP MODU IV IP40 Diverter Valves Technical Data Pipe connection Switch-over time Motor Coil resistance Supply voltage Duty cycle Circuit diagram pull in (step I to IV, I to IV, etc.) push out (step IV to I, IV to I etc.) Mating plug: AMP...

 Open the catalog to page 7
Diverter Valve-8

Diverter Valves Saia motors

 Open the catalog to page 8
Diverter Valve-9

SV Performance Chart Flow curve 180 Ball in lower position Ball in upper position Pressure Drop [mbar] Diverter Valves Pressure Drop [mbar] Ball in lower position Ball in upper position Saia motors

 Open the catalog to page 9
Diverter Valve-10

LE LE Characteristics Low pressure drop electric diverter valve Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 25/85 mbar PA6.6 GF30 0.5…3.0 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Lumberg RAST2,5 3510 P04 K20 IP00 (due to electr. connector) Technical Data clip 2s *) included 24V *) 10% movement within 5 minutes ground / open (via open collector output) (customisation e.g. PWM, 0-10V on request) Diverter...

 Open the catalog to page 10
Diverter Valve-11

Pressure Drop [mbar] Ball in lower position Ball in upper position Performance Chart Pressure Drop [mbar] Diverter Valves Ball in lower position Ball in upper position Saia motors

 Open the catalog to page 11
Diverter Valve-12

SE SE Characteristics Standard electric diverter valve Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 65/110 mbar PA6.6 GF30 0.5…3.0 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Lumberg RAST2,5 3510 P04 K20 IP00 (due to electr. connector) Technical Data clip 2s *) included 24V *) 10% movement within 5 minutes ground / open (via open collector output) (customisation e.g. PWM, 0-10V on request) Diverter Valves...

 Open the catalog to page 12
Diverter Valve-13

Performance Chart Flow curve 180 Ball in lower position Ball in upper position Pressure Drop [mbar] Diverter Valves Saia motors

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.