LC LC Characteristics Low pressure cartridge for diverter valves Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 25/85 mbar (influenced by customers valve body) PA6.6 GF30 0.5…4.5 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Tyco AMP MODU IV IP40 Diverter Valves Technical Data Pipe connection Switch-over time Motor Coil resistance Supply voltage Chopper current level Duty cycle clip 2s (depends on users sequence) bipolar stepper motor 34 Ohm 24V 200mA/coil 30% within 5 minutes Circuit diagram pull in (step I to IV, I to IV, etc.) push out (step IV to I, IV to I etc.) Mating plug: AMP connector ■ housing 0-1740209-6 ■ contact 2-167301-1 Saia motors
Open the catalog to page 1Pressure Drop [mbar] Ball in lower position Ball in upper position Ball in lower position Ball in upper position Diverter Valves Pressure Drop [mbar] Flow curve Saia motors
Open the catalog to page 2SC SC Characteristics Standard cartridge for diverter valves Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 65/110 mbar (influenced by customers valve body) PA6.6 GF30 0.5…3.0 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Tyco AMP MODU IV IP40 Diverter Valves Technical Data Pipe connection Switch-over time Motor Coil resistance Supply voltage Duty cycle clip 2s (e.g. 10steps/50Hz, 243steps/300Hz, 50steps/50Hz)...
Open the catalog to page 3diameter valve body + 0,1 0 delivery position Performance Chart Flow curve 180 Ball in lower position Ball in upper position Diverter Valves Pressure Drop [mbar] Saia motors
Open the catalog to page 4LV LV Characteristics Low pressure drop diverter valve Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 25/85 mbar PA6.6 GF30 0.5…4.5 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Tyco AMP MODU IV IP40 Technical Data Pipe connection Switch-over time Motor Coil resistance Supply voltage Chopper current level Duty cycle clip 2s (depends on users sequence) bipolar stepper motor 34 Ohm 24V 200mA/coil 30% within 5...
Open the catalog to page 5Ball in lower position Ball in upper position Pressure Drop [mbar] Performance Chart Pressure Drop [mbar] Diverter Valves Ball in lower position Ball in upper position Saia motors
Open the catalog to page 6SV SV Characteristics Standard diverter valve Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 65/110 mbar PA6.6 GF30 0.5…3.0 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Tyco AMP MODU IV IP40 Diverter Valves Technical Data Pipe connection Switch-over time Motor Coil resistance Supply voltage Duty cycle Circuit diagram pull in (step I to IV, I to IV, etc.) push out (step IV to I, IV to I etc.) Mating plug: AMP...
Open the catalog to page 7Diverter Valves Saia motors
Open the catalog to page 8SV Performance Chart Flow curve 180 Ball in lower position Ball in upper position Pressure Drop [mbar] Diverter Valves Pressure Drop [mbar] Ball in lower position Ball in upper position Saia motors
Open the catalog to page 9LE LE Characteristics Low pressure drop electric diverter valve Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 25/85 mbar PA6.6 GF30 0.5…3.0 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Lumberg RAST2,5 3510 P04 K20 IP00 (due to electr. connector) Technical Data clip 2s *) included 24V *) 10% movement within 5 minutes ground / open (via open collector output) (customisation e.g. PWM, 0-10V on request) Diverter...
Open the catalog to page 10Pressure Drop [mbar] Ball in lower position Ball in upper position Performance Chart Pressure Drop [mbar] Diverter Valves Ball in lower position Ball in upper position Saia motors
Open the catalog to page 11SE SE Characteristics Standard electric diverter valve Standard Data Flow resisttance @ 1500l/h Housing material Operating pressure Mounting position Climatic class Ambient operation temperature Ambient temperature storage Electrical connection Degree of protection 65/110 mbar PA6.6 GF30 0.5…3.0 bar any wide-spread according to DIN IEC 60721-2-1 0…70 °C -20..70 °C Lumberg RAST2,5 3510 P04 K20 IP00 (due to electr. connector) Technical Data clip 2s *) included 24V *) 10% movement within 5 minutes ground / open (via open collector output) (customisation e.g. PWM, 0-10V on request) Diverter Valves...
Open the catalog to page 12Performance Chart Flow curve 180 Ball in lower position Ball in upper position Pressure Drop [mbar] Diverter Valves Saia motors
Open the catalog to page 132 Pages
2 Pages
2 Pages
4 Pages
3 Pages
26 Pages
10 Pages
11 Pages
14 Pages
3 Pages
37 Pages
3 Pages
3 Pages
9 Pages
12 Pages
8 Pages
4 Pages
32 Pages
157 Pages
1 Page
2 Pages
2 Pages
3 Pages
38 Pages
17 Pages
91 Pages
48 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
24 Pages
112 Pages
80 Pages
54 Pages
218 Pages
22 Pages
228 Pages
228 Pages
52 Pages
231 Pages
2 Pages