Catalog excerpts

USR-M511 - 1

Technical Support: h.usriot.com Jinan USR IOT Technology Limited

Open the catalog to page 1
USR-M511 - 2

Technical Support: h.usriot.com Jinan USR IOT Technology Limited

Open the catalog to page 2
USR-M511 - 3

Technical Support: h.usriot.com Support Modbus_RTU_Master, Modbus_RTU_Slave, Modbus_ASCII_Master, Modbus_ASCII_Slave work modes. Support Modbus Master Prefetch function. Support 8 Modbus Slave automatic query by commands. Support Modbus web server management function. 10/100Mbps Ethernet interface, support Auto-MDI/MDIX. Baud rate support 600bps~230.4K bps; Support None, Odd, Even, Mark, Space. Support Static IP/DHCP. Support keep-alive. Support RS232/RS485/RS422. Support hardware Reload.

Open the catalog to page 3
USR-M511 - 4

Technical Support: h.usriot.com 1. Get Start Product link: http://www.usriot.com/p/industrial-modbus-gateway-modbus-rtuascii-modbus-tcp/ Figure 1 Download Page If you have any question, please submit it back to customer center: http://h.usriot.com Figure 2 Application diagram Jinan USR IOT Technology Limited

Open the catalog to page 4
USR-M511 - 5

Technical Support: h.usriot.com 1.2.Hardware Design 1.2.1. Hardware Dimensions Figure 3 Hardware dimensions Jinan USR IOT Technology Limited

Open the catalog to page 5
USR-M511 - 6

Technical Support: h.usriot.com 1.2.2. LED Indicator Indicator PWR WORK TX RX Status On: Power on Off: Power off On: Working Off: Not working On: Sending data to serial Off: No data sending to serial On: Receiving data from serial Off: No data receiving from serial Figure 4 Hardware Indicator 1.2.4. DB9 Pinboard We provide DB9 pinboard for user to use terminal connection. Jinan USR IOT Technology Limited

Open the catalog to page 6
USR-M511 - 7

Technical Support: h.usriot.com Jinan USR IOT Technology Limited

Open the catalog to page 7
USR-M511 - 8

Technical Support: h.usriot.com 2. Product Functions This chapter introduces the functions of USR-M511 as the following diagram shown, you can get an overall knowledge of it. Modbus Master RTU/ASCII Identity packet USR Cloud Serial port packaging Protocol Conversion Modbus Slave RTU/ASCII Serial port Serial Port Device Type(Master or Slave) Serial Port Device Modbus storing and dispatching Periodically querying by commands on serial side Serial port packaging Periodically querying by commands on network side Sending read/write commands Network requesting commands Modbus Slave status...

Open the catalog to page 8
USR-M511 - 9

Technical Support: h.usriot.com User can change Static IP/DHCP by web server. Setting diagram as follow: Figure 8 Static IP/DHCP 2.1.2. Hardware Restore default settings User can press Reload over 5s and less than 15s then release to restore default settings. 2.1.3. Upgrade Firmware Version User can contact to salespersons for needed firmware version and upgrade by setup software through Ethernet port. Setup software download link: http://www.usriot.com/usr-tcp232-m4k3-setup-software. User can upgrade as follows: Jinan USR IOT Technology Limited

Open the catalog to page 9
USR-M511 - 10

Technical Support: h.usriot.com Figure 9 Upgrade firmware version 2.2. Serial port 2.2.1. Serial Port Basic Parameter Serial port basic parameters as follow: Parameter Baud rate Data bits None, Odd, Even, Mark, Space Stop bits Flow control None: No flow control. HardWare: Hardware flow control(RTS/CTS). Xon/Xoff: Software flow control. Figure 10 Serial port basic parameter User can change serial port parameters by web server as follow: Figure 11 Serial port parameters configuration Jinan USR IOT Technology Limited

Open the catalog to page 10
USR-M511 - 11

Technical Support: h.usriot.com 2.2.2. Serial Package Methods For network speed is faster than serial. Module will put serial data in buffer before sending it to network. The data will be sent to Network as Package. There are 2 ways to end the package and send package to network - Time Trigger Mode and Length Trigger Mode.   Time Trigger Mode: Default package time is 4 bytes sending interval and use can set between 0~65535. Length Trigger Mode: Default package length is 1460 and user can set between 0~1460. 2.2.3. Baud Rate Synchronization When module works with USR devices or software,...

Open the catalog to page 11
USR-M511 - 12

Technical Support: h.usriot.com Figure 13 Modbus Master mode configuration A.Work Mode: Four types work modes. B.Enable Modbus Over TCP/IP: Open this function, M511 will work in transparent transmission and don’t proceed protocol conversion. If network side protocol is Modbus RTU/ASCII, this function must be used. If network side protocol is Modbus TCP, this function can’t be opened. C.Remote Server AddrA: Modbus Slave address, can be domain name. D.Remote Port NumberA: Default port is 502 and often keep default value. E.Slave ID Range: All querying command will be sent to this Slave in...

Open the catalog to page 12
USR-M511 - 13

Technical Support: h.usriot.com data from serial port Modbus Slaves and reply stored data to network side Modbus Masters directly. 4. Modbus work in Modbus Slave mode can apply to four applications: One Master to one Slave; one Master to multiple Slaves; multiple Masters to one Slave; multiple Masters to multiple Slaves. Application diagram as follows: Figure 14 One Master to one Slave User can change Modbus Slave mode parameters by web server as follow: Figure 15 Modbus Slave mode configuration A.Work mode: Four types work modes. B.Enable Modbus Over TCP/IP: Open this function, M511 will...

Open the catalog to page 13
USR-M511 - 14

Technical Support: h.usriot.com E.Timeout Reconnection: No data transmission over this time, M511 will automatically disconnect and reconnect remote Slave. F.Modbus Timeout: Modbus response time which must be accordant with serial port Modbus Master. 2.4. Modbus Slave management M511 support Modbus management based on Websocket. So user need use browser which can support Websocket as follow: Browser Internet Explorer Version 5+ Figure 16 Browser version 2.4.1.Modbus data monitoring User need disable Modbus Over TCP/IP function to use Modbus data monitoring function. (1)Open Modbus Manage...

Open the catalog to page 14
USR-M511 - 15

Technical Support: h.usriot.com Figure 18 Modbus slave mark configuration (3)Refresh Modbus Management and query the data. Web server will update data value without refreshing. 2.4.2.Modbus data management M511 support Modbus data management function to query Slave information through Modbus Management web-page. When user open Modbus data management function, M511 will disable querying commands from Modbus Master to Modbus Slave(close protocol conversion function). User can configure Modbus data management as follow: Figure 19 Modbus data management configuration Jinan USR IOT Technology...

Open the catalog to page 15

All Jinan USR IOT Technology Limited catalogs and technical brochures

  1. USR-MB706

    2 Pages

  2. USR-G807

    6 Pages

  3. USR-G786-G

    2 Pages

  4. USR-LG206-P

    15 Pages

  5. USR-K6

    107 Pages

  6. USR-K5

    81 Pages

  7. USR-TCP232-306

    23 Pages

  8. USR-DR302

    70 Pages

  9. USR-DR301

    70 Pages

  10. USR-DR404

    86 Pages

  11. USR-N668

    48 Pages

  12. USR-W630

    34 Pages

  13. USR-W610

    4 Pages

  14. USR-GM3

    2 Pages

  15. USR-SDR021

    4 Pages

  16. USR-SDR041

    3 Pages

  17. USR-SDR080

    3 Pages

  18. USR-SDR160

    3 Pages

  19. USR-K7

    1 Pages

  20. USR-CANET200

    3 Pages

  21. GW-R4513

    5 Pages

  22. USR-G806-A

    6 Pages

  23. USR-N540

    5 Pages

  24. USR-N510

    5 Pages

  25. USR-N520

    5 Pages

  26. USR-N580

    5 Pages

  27. USR-SDR050-L

    4 Pages