USR-K6
107Pages

{{requestButtons}}

Catalog excerpts

USR-K6 - 1

USR-K6 User Manual File Version: V1.0.0 Jinan USR IOT Technology Limited

Open the catalog to page 1
USR-K6 - 2

Jinan USR IOT Technology Limited

Open the catalog to page 2
USR-K6 - 3

Jinan USR IOT Technology Limited

Open the catalog to page 3
USR-K6 - 4

Jinan USR IOT Technology Limited

Open the catalog to page 4
USR-K6 - 5

1. Get Start USR-K6 is a small module for serial port to Ethernet, which can realize the bi-directed data transparent transmission between RJ45 port and TTL serial port. It can be applied to interface 232 and 485 by level conversion circuit. Product link: https://www.usriot.com/products/low-cost-solution-super-port-ethernet-module.html Related software:  M0 setting software: https://www.usriot.com/support/downloads/usr-m0-setup-software-v224288.html (which can be also used in the the low cost serial to ethernet converters such as USR-TCP232-302, USR-TCP232-304 and USR-TCP232-306, and...

Open the catalog to page 5
USR-K6 - 6

Diagram 1-1 Download Page Some question in you using, please refer to the applications:http://www.usr.cn/Faq/cat-46.html Also can be submit to our USR custom supporting: http://h.usriot.com 1.1. Testing Environment 1.1.1. Hardware Prepare  Jinan USR IOT Technology Limited

Open the catalog to page 6
USR-K6 - 7

Serial port cable *1 Diagram 1.1.1-1 Testing Tools 1.Test purposes: Test to realize the USR-K6, have a basic understanding of USR-K6 Test to know whether there are some thing wrong with it. 2.Data direction: Diagram 1.1.1-2 Data Direction Jinan USR IOT Technology Limited

Open the catalog to page 7
USR-K6 - 8

1.1.2. Hardware Connection To test the conversion from serial port to ethernet, we put the serial port of K6 connected to PC via serial cable. Connect the interface of the K6 and PC using net cable. After testing and found no mistake, powered for K6. Diagram 1.1.2-1 Hardware Connection Note: the power adapter and the cable are from USR 1.2. Network Testing To prevent the thing that occurs when the custom use the K6 such as finding no server, can not ping and can not enter the webpage, after connecting you should check the PC before testing. 1)Shut down firewall and antivirus software....

Open the catalog to page 8
USR-K6 - 9

Diagram 1.2-1 Local Connection of the PC 1.3. Default Parameters Project User name Subnet masks Default network gateway Default work mode Default local port Default target port Default local port Jinan USR IOT Technology Limited

Open the catalog to page 9
USR-K6 - 10

Serial port baud Serial parameter None/8/1 Form 1.3-1 Default Parameters 1.4. Data Transport Testing Then the serial port and ethernet can communicate bi-directly, steps are as fellows: ① Open the”USR-TCP232-Test.exe” and connect the hardware as the Diagram 1.1.2-1 Hardware Connection ② Select the TCP server mode in the “Net Setting” . Fill the PC IP into the server IP, server port 8324, click to start listen and build TCP client. Baud rate:115200, serial parameters:None/8/1, then click to open the serial port. Diagram 1.4-1 Default Parameters Testing Jinan USR IOT Technology Limited

Open the catalog to page 10
USR-K6 - 11

2. Overview 2.1. Brief Introduction USR-K6 is a tiny size serial port to Ethernet module which can realize the bi-direct data transparent transmission between RJ45 port and TTL serial port. It can be applied to RS232 and RS485 by level conversion circuit. Supports low power consumption, only consume a little current in full speed work. Equipped with Cortex-M0 core, fast speed and high efficiency. Supports several functions to meet more need. K6 is easy to operate and have strong compatibility. On the basis of adding new functions, it is compatible with the setting protocol of K5, which...

Open the catalog to page 11
USR-K6 - 12

restart out time, the time can be set. ort DNS, domain name resolution. tore to the factory setting. 2.3. Basic Parameters Parameter Input Voltage Working Current Serial port Software parameters Network protocol Jinan USR IOT Technology Limited

Open the catalog to page 12
USR-K6 - 13

User parameters command Single transparent transmission TCP Server/TCP client/UDP Server/UDP Client Httpd client Serial port buffer Average transport delay USR-VCOM, USR-Cloud, parameters setting software Package mechanism 4 byte package time and 1024byte length others Certification Operating Temp. Storage temp operating humidity Storage humidity Jinan USR IOT Technology Limited

Open the catalog to page 13
USR-K6 - 14

Electrostatic bubble Form 2.3-1 Basic Parameters 3. Hardware Parameters 3.1. Pin Definition Jinan USR IOT Technology Limited

Open the catalog to page 14
USR-K6 - 15

Used as indication pin for TCP connection status. If the LINK function is enable and connected, this LED will light. Connected to the IP of the user’s MCU, reset when abnormal, reset when the pin reach 200ms When normal working , don’t connect the pin or connect to using serial high level. Under low level, the pin is used for module configuration, access to power then pull down“Reload” pin Refer to 4.4.3 Factory Reset Net port data instr Single chip data indicator foot, when data transport in the network, it will flash. Module data send Signal location Jinan USR IOT Technology Limited

Open the catalog to page 15
USR-K6 - 16

4. Product Function Here are the functions of K6, below is the overall block diagram. Jinan USR IOT Technology Limited

Open the catalog to page 16
USR-K6 - 17

4.1. Network Basic Functions 4.1.1. IP address/ subnet masks/ gateway 1. IP address is the identity representation of the module in the LAN, which is unique in the LAN, so please be sure there is no another device same as it in the LAN.  Handle to setting. Note fill the IP, subnet masks and gateway. Static IP adopted to the environment that required to statistics the IP and the device and makes them correspond one to one. Advantage: accessing the device that can not distribute IP address can be searched via UDP broadcast. Disadvantage: different net segment in the different LAN can not...

Open the catalog to page 17
USR-K6 - 18

Get IP address , gateway address, DNS server and other information from the gateway server to easy the step for setting IP address, DHCP adopted to the environment that have no special requirement to IP. Advantage: accessing the device equipment with the DHCP server such as router can communicate directly. Reduce the hassle of setting IP address and subnet masks. Disadvantage: accessing the device with no DHCP server such as computer directly, K6 can not work. 2. Subnet masks used to determine the host number and the network number, indicates the number of subnet and determine the flag...

Open the catalog to page 18

All Jinan USR IOT Technology Limited catalogs and technical brochures

  1. USR-MB706

    2 Pages

  2. USR-G807

    6 Pages

  3. USR-G786-G

    2 Pages

  4. USR-LG206-P

    15 Pages

  5. USR-M511

    19 Pages

  6. USR-K5

    81 Pages

  7. USR-TCP232-306

    23 Pages

  8. USR-DR302

    70 Pages

  9. USR-DR301

    70 Pages

  10. USR-DR404

    86 Pages

  11. USR-N668

    48 Pages

  12. USR-W630

    34 Pages

  13. USR-W610

    4 Pages

  14. USR-GM3

    2 Pages

  15. USR-SDR021

    4 Pages

  16. USR-SDR041

    3 Pages

  17. USR-SDR080

    3 Pages

  18. USR-SDR160

    3 Pages

  19. USR-K7

    1 Pages

  20. USR-CANET200

    3 Pages

  21. GW-R4513

    5 Pages

  22. USR-G806-A

    6 Pages

  23. USR-N540

    5 Pages

  24. USR-N510

    5 Pages

  25. USR-N520

    5 Pages

  26. USR-N580

    5 Pages

  27. USR-SDR050-L

    4 Pages