video corpo

USR-K5

USR-K5
1 / 81 PagesView full catalog

USR-K5

Product catalog summary
Features
  • Supports 10/100Mbps Ethernet with AUTO-MDIX for automatic cable switching.
  • Operates in TCP server, TCP client, UDP server, and UDP client modes.
  • Configurable baud rate from 600bps to 230.4Kbps with various parity options.
  • Customizable heartbeat and registration packages for connection reliability.
  • TCP Server mode supports up to 4 clients with client management options.
  • Supports DHCP, DNS, and firmware upgrades via web interface.
  • Offers software and hardware reset to factory settings and supports LAN and external access.
Getting Started
  • Quick Test: Involves hardware connection, network test environment setup, and K5 settings configuration.
  • Basic Parameters: Describes bi-directional data transmission capability between RJ45 and TTL serial ports.
Configuration
  • Configuration by Windows Utility: Involves installing setup software and searching for device servers over a LAN.
  • Configuration by Web Console: Includes network connection, web page server setup, and various network settings.
Security Considerations
  • Includes restoring to factory settings and network firmware upgrades.
Network and Serial Port Configurations
  • Details on TCP Client, TCP Server, UDP Client, and UDP Server configurations.
  • Serial Port Function: Covers basic parameters, serial port framing, and RFC2217 support.
Advanced Functions
  • Heartbeat and registration packages for enhanced communication reliability.
  • USR IOT CLOUD and Scada cloud integration.
Parameter Setting
  • Net Protocol and Web Page Setting Parameters: Detailed instructions for setting software and protocol parameters.
AT Command
  • Overview and details of AT commands, including error codes and command specifics.
Contact and Disclaimer
  • Contact information and disclaimer notes.
Product Specifications
  • Dimensions: 35.0x19.4x16.55 mm (L*W*H)
  • Operating Temperature: -40 to +85°C
  • Storage Temperature: -45 to +105°C
  • Operating Humidity: 5% to 95% RH
  • Storage Humidity: 5% to 95% RH
  • Package: Electrostatic bubble
IP Mode Configuration
  • Static IP: Requires manual setting of IP, mask, and gateway.
  • DHCP: Automatically obtains IP and other network information from a DHCP server.
  • Subnet Masks: Typically set to 255.255.255.0.
  • Gateway: Usually the router's IP address.
  • AT Commands: Used for setting and querying IP parameters.
Configuration by Windows Utility
  • Installation of M0 Setup software is required for device configuration over a network.
  • The Broadcast Search function locates all K5 device servers on the same LAN.
Configuration by Web Console
  • Connect via Ethernet and access the web server using default IP 192.168.0.7.
  • Default login credentials are 'admin' for both username and password.
Security Considerations
  • Restore to Factory Settings: Can be done via hardware, software, or AT command.
  • Network Upgrade Firmware: Firmware can be upgraded through the web page.
Network and Serial Port Configurations
  • Supports five work modes: TCP Client, TCP Server, UDP Client, UDP Server, and Httpd Client.
  • Default IP address is static at 192.168.0.201 with a default remote port of 8234.
TCP Server Mode
In TCP Server Mode, the K5 device listens on a local port and establishes a connection upon receiving a request. It sends received data to all connected clients and monitors connections using a keep-alive function. This mode is typically used in LAN communications with multiple clients. The number of TCP clients ranges from 1 to 16, with a default of 4.
UDP Client Mode
In UDP Client Mode, the K5 does not actively establish connections. It communicates with a pre-set target port and can perform network broadcasts if the target IP is set to 255.255.255.255.
UDP Server Mode
The UDP Server Mode allows communication without verifying the source IP address. It is used for high-frequency communications where TCP is not preferred.
Serial Port Functionality
The serial port supports various parameters such as baud rate (600~230.4Kbps), data bits (7 or 8), stop bits (1 or 2), and parity (none, odd, even, mark, space).
RFC2217 Protocol
The RFC2217 protocol allows dynamic changes to serial port parameters, enabling automatic matching between PC software and the K5 device.
Advanced Functions
  • Heartbeat Package: In transparent transport mode, the K5 can send heartbeat packages to maintain server connections.
  • Registration Package: Used to identify data sources or obtain server authorization.
USR IOT CLOUD
The USR IOT CLOUD provides a comprehensive solution for equipment manufacturers, including features like cloud configuration and detection.
Serial to Ethernet
The VCOM software facilitates communication between the K5 and virtual serial ports.
Parameter Setting
The document outlines how to configure K5 parameters for personalized applications.
Overview: This document provides detailed instructions for setting up and configuring the USR-LTE-7S5 device, including network protocol settings, serial port parameters, and firmware upgrades.
1. User Setting Steps:
  • Modify username and password.
  • Set access via IP address.
  • Configure serial parameters and working method.
2. Software Setup Requirements:
  • Ensure K5 and PC are on the same LAN.
  • Disable antivirus and firewall software.
3. Network Protocol Setting Parameters:
  • Use the provided software to search for K5 devices on the LAN.
  • Access device parameters using default credentials.
4. Serial Port Parameters:
  • Set baud rate, parity, data, and stop bits.
  • Choose work mode (TCP/UDP).
5. Firmware Upgrade:
  • Consult sales for upgraded firmware.
6. Network Setting Protocols:
  • Use UDP mode for communication.
7. Command Protocols:
  • Commands include search, restart, read settings, and basic parameter settings.
8. Additional Commands:
  • Restore to factory settings.
  • Configure USR IOT Cloud and heartbeat/registration packages.
9. Return Command Results:
  • Details on search command return and parity calculation.
Overview: This document provides technical specifications and operational procedures for the USR-LTE-7S5 device.
Specifications: The document specifies the firmware version, application title, and device name.
Command Responses: The document details various command responses for operations such as restarting the device.
Parameter Settings: Instructions are provided for setting basic, serial, USR-cloud, and heartbeat registration parameters.
Web Page Configuration: Users can configure the device via a web interface by entering the default IP address.
AT Commands: A comprehensive list of AT commands is provided for querying and setting device parameters.
Error Codes: The document lists error codes for invalid formats, orders, operators, and parameters.
Usage Instructions: Detailed instructions are given for entering and exiting command modes.
AT Command Functions Overview
  • AT+RFCEN: Enables or disables the RFC2217 function.
  • AT+PDTIME: Queries the produce time of the device.
  • AT+REGEN: Configures the registration package mechanism.
  • AT+REGTCP: Sets the TCP client mode registration package mechanism.
  • AT+REGCLOUD: Manages USR-cloud username and password settings.
  • AT+REGUSR: Customizes registration package content.
  • AT+HEARTEN: Enables or disables the heartbeat package function.
  • AT+HEARTTP: Configures the sending method for heartbeat packages.
  • AT+HEARTTM: Sets the heartbeat package time.
  • AT+HEARTDT: Customizes heartbeat package content.
  • AT+SCSLINK: Manages socket connection status instructions.
  • AT+CLIENTRST: Configures TCP client mode to reset after multiple failed connection attempts.
  • AT+INDEXEN: Enables or disables the index function.
  • AT+SOCKSL: Manages the short connection function.
  • AT+SHORTO: Sets the short connection time.
  • AT+UARTCLBUF: Clears or retains the serial port cache before connection.
  • AT+RSTIM: Configures restart timeout.
  • AT+MAXSK: Sets the maximum number of clients that a TCP server can connect to.
  • AT+MID: Manages the module name.
  • AT+SEARCH: Searches for ports and keywords in the LAN.
  • AT+H: Provides help information.
Contact Information
Jinan USR IOT Technology Limited provides contact details for technical support and inquiries.
Disclaimer
The document is subject to change without notice, and reproduction requires written permission.
See more

Catalog excerpts

USR-K5-1

Jinan USR IOT Technology Limited

 Open the catalog to page 1
USR-K5-2

Features 10 / 100Mbps adaptive Ethernet interface, support AUTO-MDIX network cable crossover and direct  connection automatic switching. Work modes:TCP server, TCP client, UDP server, UDP client.  Baud rate can be set from 600bps to 230.4Kbps. Parity supports None, Odd, Eben, Mark, Space.  Customize heartbeat package and keep the connection real and reliable, can be used to detect the  dead connections Customize registration package, detect the connection status, and also customize the head of package.  In TCP Server mode, the number of connected clients can be modify from 1 to 4, default...

 Open the catalog to page 2
USR-K5-3

technical support:h.usriot.com

 Open the catalog to page 3
USR-K5-4

technical support:h.usriot.com Jinan USR IOT Technology Limited

 Open the catalog to page 4
USR-K5-5

technical support:h.usriot.com 1. Get start 1.1.Quick Test 1. USR - K5 2. USR - Kx - EVK 3. One Internet cable 4. One power supply of DC5V 1A 5. Serial line 6. One PC Hardware connection To test a serial port to network communication conversion, we will K5 (USR - K5, referred to as "K5, similarly hereinafter) serial port via a serial port line (or turn the USB serial port) connected to the computer, the K5 with cable front-end ports and connected to the front-end ports of the PC, hardware connection without error, access our distribution power adapter, to power a K5, connection diagram as shown:...

 Open the catalog to page 5
USR-K5-6

technical support:h.usriot.com 3) for the case where the server is directly connected to PC, a static IP address in the same network segment as K5 IP must be set for the computer; Computer settings You can set up the parameters as the follows default parameters through M0 set-up software or inner website. You can check the details at chapter 3. Default parameter User name Password IP Subnet mask Work mode Work mode Local port Remote port Default remote port Serial-port baud rate Jinan USR IOT Technology Limited

 Open the catalog to page 6
USR-K5-7

Jinan USR IOT Technology Limited technical support:h.usriot.com Software settings

 Open the catalog to page 7
USR-K5-8

technical support:h.usriot.com Data transmission test After the above steps are confirmed to be correct, the two-way communication between the serial port and the Ethernet port can be carried out. The operation steps are as follows: 1) open the Test software usr-tcp232-test.exe, and connect the hardware according to figure 1.2. 2) select TCP Server mode in the network setting area, input the computer IP address of the Server, input the port number of the Server 8234, click to start listening, establish the TCP connection, set the baud rate of the serial port to 115200, set the serial port parameter...

 Open the catalog to page 8
USR-K5-9

technical support:h.usriot.com 1.2.Basic Parameters USR-K5 is a tiny size serial port to Ethernet module which can realize the bi-direct data transparent transmission between RJ45 port and TTL serial port. It can be applied to RS232 and RS485 by level conversion circuit. Supports low power consumption, only consume a little current in full speed work. Equipped with Cortex-M0 core, fast speed and high efficiency. Supports several functions to meet more needs. K5 is easy to operate and have strong compatibility. On the basis of adding new functions, it is compatible with the setting protocol of...

 Open the catalog to page 9
USR-K5-10

operating humidity technical support:h.usriot.com Electrostatic bubble Storage humidity 1.3.Product Function Here are the functions of K5, below is the overall block diagram. Jinan USR IOT Technology Limited

 Open the catalog to page 10
USR-K5-11

technical support:h.usriot.com 1.4.IP Mode IP address/ Mask/ Gateway 1. IP address is the identity representation of the module in the LAN, which is unique in the LAN, so please be sure there is no another device same as it in the LAN. The static IP needs to be manually set by the user. During the setting process, pay attention to write the IP, mask, and gateway at the same time. The static IP is suitable for scenarios where IP and equipment need to be counted and one-to-one correspondence is required. Pay attention to the corr/espondence between IP address, mask and gateway when setting. When...

 Open the catalog to page 11
USR-K5-12

technical support:h.usriot.com Software Setting You can easily install and configure your device server over the network In this section, we will cover only the “configuration of general settings” using N510 Administrator. For more detailed information on how to use this suite of useful utilities, refer to Chapter 3 and 5. 1.5.1. Installing M0 Set-up software Download and run (https://www.usriot.com/support/downloads/usr-m4-setup-software-v235102.html ). You may find it in the Resource section under your product page. 1.5.2. Searching for Device Servers over a LAN The Broadcast Search function...

 Open the catalog to page 12
USR-K5-13

technical support:h.usriot.com In M0 software, click Search to search your LAN for device servers. When your unit appears in the search results,You may also wait a few more moments for the search to complete. Figure 8 Search device Right-click your unit in the Configuration screen and select Configure in the menu.The device server must be assigned a unique IP address that is valid for your network. Both static and dynamic IP addresses are supported. The ip type you can check the details refer to Chapters 2 for a detailed explanation of different operating Consult with your network administrator...

 Open the catalog to page 13
USR-K5-14

technical support:h.usriot.com 1.6.Configuration by web console 1.6.1. Connect with Network Connect one end of the Ethernet cable to the 10/100M Ethernet port and the other end of the cable to the Network .The device will indicate a valid connection to the Ethernet in the following ways: Open your browser User can connect PC to N510 through LAN port and enter Web Server to configure. Web Server default parameters as follow: Diagram 2 Parameter Web server IP address User name Password Jinan USR IOT Technology Limited Default settings Web server default parameters

 Open the catalog to page 14
USR-K5-15

technical support:h.usriot.com After firstly connecting PC to K5, user can open browser and enter default IP 192.168.0.7 into address bar, then log in user name and password, user will enter Web site: K5 is same as the normal web page server, which is convenient for user to setting parameter and query the status. The port of web page can be setting, default is 80. Steps:  Open the browser, fill the IP of K5, e.g.:192.168.0.7(IP address and PC in the same net segment.)  Fill the user name and key word in the login web page, default is admin, click to enter. TX Count: the data count sent from...

 Open the catalog to page 15
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.