Overview: The AQM-RK14V is a seven-in-one air quality module designed for cost-effective environmental monitoring. It integrates sensors for CO2, formaldehyde, TVOC, PM2.5, PM10, temperature, and humidity, providing real-time data output via a digital serial port.
Application Areas: This module is suitable for use in hotel room air quality monitoring, fresh air ventilation systems, air purifiers, air conditioners, kitchen and bathroom ventilation control systems, smart home equipment, and environmental monitoring in agricultural greenhouses and outdoor breeding places.
Features: The module outputs seven sets of data simultaneously, ensuring high sensitivity and stable data. It supports RS485 bus and UART TTL level output, with options for customization (e.g., RS232, WIFI, Lora, Cat1). The temperature and humidity measurements are accurate to 0.1°C and 0.1% respectively. Data is output every second through the UART TTL interface, and the module includes power supply reverse connection protection.
Specifications:
  • eCO2: 1ppm resolution, 400-4500ppm range, ±25% accuracy
  • HCHO: 1ug/m3 resolution, 0-2000ug/m3 range, ±25% accuracy
  • TVOC: 1ug/m3 resolution, 0-9999ug/m3 range, ±25% accuracy
  • PM2.5: 1ug/m3 resolution, 0-999ug/m3 range, ±10% accuracy
  • PM10: 1ug/m3 resolution, 0-1000ug/m3 range, ±10% accuracy
  • Temperature: 0.01°C resolution, -40°C to 100°C range, ±0.3°C accuracy
  • Humidity: 0.04% resolution, 0-100% range, ±3%RH accuracy
Physical and Operational Details: The module measures 61x48x13mm and operates at 5.0±0.2VDC with a working current of ≤60mA. It requires a preheat time of 3 minutes for eCO2, HCHO, and TVOC measurements. The operating temperature range is 0°C to 50°C, with a working humidity of ≤95%RH. The service life is 5 years with a one-year warranty.
Data Communication: The module uses a UART interface with a baud rate of 9600bps, 8 data bits, 1 stop bit, and no check digit. Data is automatically uploaded at a frequency of 1Hz. The serial data stream includes module address, version number, data for each parameter, and a checksum for validation.
Note: The eCO2 and HCHO values are equivalent values of TVOC. The temperature data format indicates negative or positive values based on bit7 of the temperature data byte.
See more

Catalog excerpts

Seven in one  air quality module-1

Seven-in-one Air Quality Module (Model: AQM-RK14V) Description The AQM-RK14V seven-in-one air quality module is a cost-effective digital serial port output sensor module, using serial TTL level output mode, integrating CO2, formaldehyde, TVOC, laser PM2.5, PM10, temperature and humidity in one. It can conduct real-time and comprehensive detection of the environment, has good stability, and is very convenient for customers to use. Hotel room air quality monitoring Fresh air ventilation system Air purifier, air conditioner Air quality monitoring equipment Kitchen and bathroom ventilation control system Smart home equipment Environmental monitoring of agricultural greenhouses and outdoor breeding places Features: ● Simultaneously output seven sets of data of carbon dioxide, formaldehyde, TVOC, PM2.5, PM10, temperature and humidity ● High sensitivity and stable data ● RS485 bus and UART TTL level output mode, we can also provide customized services according to customer requirements (such as RS232, WIFI,lora,Cat1). ● The temperature is accurate to 0.1℃, and the humidity is accurate to 0.1% ● The seven groups of monitoring data are automatically output through the UART TTL interface every second ● With power supply reverse conne

 Open the catalog to page 1
Seven in one  air quality module-2

Specifications: Measurement Measurement Range Measurement Accuracy Resolution eCO2 1ppm 400~4500ppm ±25% HCHO 1ug/m3 0~2000ug/m3 ±25% TVOC 1ug/m3 0~9999ug/m3 ±25% PM2.5 1ug/m3 0~999ug/m3 ±10% PM10 1ug/m3 0~1000ug/m3 ±10% Temperature 0.01℃ -40℃~100℃ ±0.3℃ Humidity 0.04% 0~100% ±3%RH Physical interface ZH2.54 female Output Data UART Operating Voltage 5.0±0.2VDC Working current ≤60mA 3 minutes (Only eCO2, HCHO and TVOC need to be preheated, other Preheat time parameters will be displayed after power-on) Operating temperature 0℃~50℃ Working humidity ≤95%RH Dimensions 61*48*13mm(L×W×H) Service life...

 Open the catalog to page 2
Seven in one  air quality module-3

Note: The eCO2 value and HCHO value output by the module are the equivalent values of TVOC, please pay attention when purchasing and using it. UART interface definition: Interface 1 2 3 4 Features Connect to power DC 5V UART data output pin Signal input pin Signal output pin Communication command: Baud rate Data bit Stop bit Check Digit After the module is powered on, the data is automatically uploaded, the frequency is about 1HZ. Module address version number data data data data high byte low byte high byte low byte

 Open the catalog to page 3
Seven in one  air quality module-4

data data data data data data data data data data Checksum TVOC high byte TVOC low byte PM2.5 high byte PM2.5 low byte PM10 high byte PM10 low byte Temperature integer part Temperature fractional part Humidity integer part Humidity fractional part Checksum The temperature is accurate to 0.1℃, and the humidity is accurate to 0.1%. When the bit7 of the temperature data B13=1, it represents a negative temperature, and when the bit7=0 of B13, it is a positive temperature. For example, when B13=9Bh, bit7=1 at this time, it means negative temperature, and the actual temperature is -27℃; if B13=1Bh,...

 Open the catalog to page 4
Seven in one  air quality module-5

UART connection diagram: