JC35N6 Linear Actuator Application field - Medical Line & Reha Line & Technical Line Preferably in medical rehabilitation equipment and other industrial occasions. With a small size and outstanding performance, the JC35N6 provides a practical and alternative to small traditional rehabilitation systems like wheelchairs. With high protection class of max. IPX6, JC35N6 is also available for some technical applications which requires load of 600N yet small sizes. Features And Options Dynamic Load In Push (N): Dynamic Load In Pull (N): Colour: Protection Class: Stroke Length (mm): Installation Dimension: Noise Leve: Options: Standard: Built-in Electronic Limit Switch: Weight: Static Bending Moment: Black Max. IPX6 600N: 30-300mm 1200N: 30-300mm L=S+155 (30≤S≤300,Standard) L=S+170 (30≤S≤300,With Hall sensor/Built in overcurrent protection) L≤470 Standard/Hall sensor ≤55dB (environmental noise ≤40dB) Built-in overcurrent protection version ≤50dB (environmental noise ≤40dB) Hall sensor Mechanical end stop Built in overcurrent protection optional (cannot be selected at the same time as Hall feedback), the push rod stops at the top by blocking the rotation (When the version without built-in overcurrent protection is selected, it is not allowed to be matched with an unprotected system. It is recommended that the overcurrent protection value be set to 2A.) About 0.7kg (different stroke length and installation dimensions with different weight) Lateral l
Open the catalog to page 1Usage 10%, max. continuous work for 2min. and 18 min. off Duty Cycle: Operating Temperature: Reserve Temperature: Matching with JIECANG control box Relative Humidity: Atmospheric Pressure: 135 (Hall sensor/Built-in overcurrent protection) L=S+170 (S≤300,Hall sensor/Built-in overcurrent protection) 120 (standard) 135 (Hall sensor/Built-in overcurrent protection) L=S+155 (S≤300,standard)
Open the catalog to page 2O JIECANG Technical Specifications (Standard Value) Remarks: It can achieve better self-locking ability with Jiecang control box; The above data is the standard value of the test data (inspection specification) at room temperature of 25°C. Diagram of relationship between stroke length and load Characteristic Curve Typical speed - Typical current -
Open the catalog to page 3O JIECANGOrdering KeyTake JC35N600D67D424100/2550BTLF220020D5 as an example Model
Open the catalog to page 4O JIECANGOrdering Details Dimensions of clevis
Open the catalog to page 5O JIECANG 4 Pin Din connector (standard/Built-in over-current protection)
Open the catalog to page 6O JIECANG Strictly abiding by medical safety certifications Passed EMC tests. To ensure our products pass all kinds of tests domestic or abroad. Aiming at different applications, develop more extensive functions for control system. Powerful R&D strength, fully satisfy customers’ needs. Development cycle is about 10 days, seizing more market opportunities Intelligent Control of Bluetooth Mobile phone as the remote, applying in home care. Market pioneer, Jiecang provides better choices Wireless Communication Controllers adopt high-frequency wireless system. It can avoid interference mixing with...