Application field - Medical Line & Care Line Preferably in hospital bed, operation table and home care bed etc. JC35L30 is a durable yet quiet actuator. It has rich specifications and can be used to both push and pull applications. JC35L30 has 2 versions: standard and fast version(4000N). It enables JIECANG to offer the hospital beds a powerful, elegant and safe product. Mechanical end stop structure, safety nut is available for JC35L30. Features And Options Dynamic Load Push(N): Dynamic Load Pull(N): Colour: Protection Class: Stroke Length: Installation Dimension: Noise Level: Options: Limit Switch: Weight: Static Bending Moment: Approval: Safety nut, Hall sensor, Only push, Signal switch+Mechanical end stop Built-in (electronic) About 2kg (different stroke length and installation dimensions with different weight) Lateral load is not allowed IEC60601-1: 2012 EN 60601-1: 2006+A12:2014 ANSI/AAMI ES60601-1: 2005/(R)2012 and A1: 2012 C1:2009/(R)2012 and A2: 2010/(R
Open the catalog to page 1Usage Duty Cycle: Operating Temperature: Reserve Temperature: Supporting Control Box: Relative Humidity: Atmospheric Pressure: 10%, max. continuous work for 2min. and 18 min. off +5℃ to +40℃ -10℃ to +50℃ Matching with JIECANG control box Under 30℃, 20% to 90%, non-condensing 700 to1060hPa
Open the catalog to page 2Technical Specifications (Standard Value) Input voltage (VDC) Speed at no load/full load (mm/s) Current at full load (A) Diagram of relationship between stroke length and load 10
Open the catalog to page 3Characteristic Curve Typical speed Min. speed Typical current Max. current
Open the catalog to page 4Ordering Key Take JC35L3006424200/375HGB34LF162022D0 as an example Model JC35L30 0 = Standard / P = Only push / S = Safety nut / Y = Hall sensor Optional features PY = Only push + Hall sensor / SY = Safety nut+Hall sensor F=Fast version / B= Signal switch+Mechanical end-stop Speed at full load XX Stroke length/ lnstallation dimension Cable length Installation dimension = XXX H=horizontal V=vertical (to motor direction) Type of connector and cable Front clevis specification B34: Slot 6.5; depth 39, hole 10.1 with bushing B46: B46: hole 10.1 with bushing (black) B47: hole 10.1 with bushing (gray)...
Open the catalog to page 5Ordering Details Dimensions of clevis End clevis: B34 24.5
Open the catalog to page 6Dimensions of JC35L30 with control box
Open the catalog to page 7Motor cable 4 Pin Din connector (standard) Supporting control box : Outer Circle 5 Pin Din connector (with Hall sensor) Hall sensor signal 1
Open the catalog to page 96 Pin Mini-Fit elbow connector Supporting control box : JCB35T2 / JCB35T3 / JCB35Q3 When not in the lower limit, it is connected with red power with positive voltage, actuator going down When not in the upper limit, it is connected with yellow power with positive voltage, actuator going up When not in the lower limit, it is connected with orange When not in the upper limit, it is connected with black
Open the catalog to page 10Communication protocol development Professional customization Intelligent Control of Bluetooth better choices Wireless Communication Latest Weighing System Disclaimer and Exclusion of Liability