1. Catalogs
  2. Jiecang Linear Motion
  3. JIECANG Linear Actuator JC35L28

JIECANG Linear Actuator JC35L28

JIECANG Linear Actuator JC35L28

JIECANG Linear Actuator JC35L28

Product catalog summary
Overview: The JC35L28 is a high-speed, efficient linear actuator known for its quiet operation and durability. It is rated IPX6, making it suitable for various applications, including patient lifts.
Specifications: The actuator is available in two main configurations: standard and patient lift, both capable of handling loads of 8000N or 10000N. The standard version can handle full stroke loads, while the patient lift version is optimized for 1/4 stroke loads.
Features and Options: The JC35L28 features a dynamic load push capability, a noise level of ≤48dB, and a weight of approximately 3kg. It is flame retardant (UL94 HB grade) and approved by several standards, including IEC60601-1:2012. Optional features include a Hall sensor, manual operation, and a signal switch.
Installation Dimensions: The patient lift version has installation dimensions of L=S+260 (for S between 50 and 300) and L=S+290 (for S between 300 and 400). The standard version dimensions are L=S+185 (for S between 50 and 250).
Technical Specifications: The actuator operates at a duty cycle of 10%, with a maximum continuous work time of 2 minutes followed by 18 minutes off. It functions within a temperature range of +5℃ to +40℃ and supports relative humidity levels of 20% to 90% at 30℃.
Ordering Key: The ordering key provides a detailed breakdown of model options, including load capacity, speed, voltage, stroke length, and additional features like color and connector type.
Disclaimer: JIECANG emphasizes the importance of determining product suitability for specific conditions and notes that product information may change without notice. Sales are subject to JIECANG's sales and delivery standard clauses.
See more

Catalog excerpts

JIECANG Linear Actuator JC35L28-1

JC35L28 Linear Actuator 1. JC35L28 is a quiet and durable actuator with high speed and high efficiency. It is rated up to IPX6, which makes it a preferable choice for different market and applications. JC35L28 is available for below specifications: JC35L28-10000N / 8000N (Standard); JC35L28-10000N / 8000N (patient lift). 2. JC35L28 has a very elegant and compact design. JC35L28 works efficiently as well: a. JC35L28-standard can load 8000N / 10000N on full stroke b. JC35L28-patient lift can load 8000N / 10000N on 1/4 full stroke. Features And Options Dynamic Load Push(N): Dynamic Load Pull (N): Colour: Protection Class: Stroke Length: Installation Dimension: Noise Level: 10000N | 8000N / Gray Max. IPX6 Patient lift version: 50-400mm(in steps of 4mm) Standard version: 50-250mm (in steps of 4mm) Patient lift version: L=S+260(50≤S≤300, with manual operation) L=S+290(300<S≤400, with manual operationl) Standard version: L=S+185( 50≤S≤250, standard) ≤48dB, ( environmental noise≤40dB) Safety nut, Manual operation Hall sensor, Only push, Manual operation, Signal switch Limit Switch: Weight: Built-in (electronic) About 3kg (different stroke length and installation dimensions with different weight ) Static Bending Moment: Lateral load is not allowed Flame Retardant Grade:

 Open the catalog to page 1
JIECANG Linear Actuator JC35L28-2

Usage Duty Cycle: Operating Temperature: Reserve Temperature: Supporting Control Box: Relative Humidity: Atmospheric Pressure: 10%, max. continuous work for 2min. and 18 min. off +5℃ to +40℃ -10℃ to +50℃ Matching with JIECANG control box 20% to 90% at 30℃, non-condensing 700 to1060hPa Dimensions Patient lift version,front clevis F92,end clevis B40 L=S+260(50≤S300) L=S+290(300<S≤400) 124

 Open the catalog to page 2
JIECANG Linear Actuator JC35L28-3

Standard version, front clevis F81,end clevis B40 Technical Specifications (Standard Value) Input voltage (VDC) Speed at no load/full load (mm/s) Current at full load (A) Remarks: It can achieve better self-locking ability with Jiecang control box; The above data is the standard value of the test data (inspection specification) at room temperature of

 Open the catalog to page 3
JIECANG Linear Actuator JC35L28-4

Diagram of relationship between stroke length and load

 Open the catalog to page 4
JIECANG Linear Actuator JC35L28-5

Characteristic Curve Typical speed Min. speed Typical current Max. current Load capacity(KN) Load capacity(KN) Load capacity(KN) Load capacity(KN)

 Open the catalog to page 5
JIECANG Linear Actuator JC35L28-6

Ordering Key Take JC35L28X105D529350/640HGB40LF922022D0 as an example Model Optional features 0 = Standard | P = Only push | S= Safety nut Y = Hall sensor | PY = Only push + Hall sensor X = Manual operation | SY = safety nut + hall sensor N = Only push + safety nut + hall sensor B= signal switch+mechanical end stop Speed at full load Stroke length/ lnstallation dimension H=horizontal V=vertical (to motor direction) Front clevis specification Type of connector and cable Cable length Stroke length=XXX Installation dimensions =XXX B40=slot 6.5, depth 30.5, φ10.1 with plastic bushing L=Aluminium...

 Open the catalog to page 6
JIECANG Linear Actuator JC35L28-7

Ordering Details Dimensions of clevis Patient lift version,front clevis:F60 Standard version,front clevis F81 Motor cable power with positive voltage, actuator going down power with positive voltage, actuator going up Outer Circle

 Open the catalog to page 7
JIECANG Linear Actuator JC35L28-8

5 Pin DIN connector (with Hall sensor) Supporting control boxes: JCB35Q / JCB35T / JCB353R / JCB35R1 / JCB35S power with positive voltage, actuator going down power with positive voltage, actuator going up Hall sensor signal 1 Hall sensor signal 2 Outer Circle 6 Pin Mini-Fit elbow connector Supporting control box : JCB35T2 / JCB35T3 / JCB35Q3 / JCB35K3 When not in the lower limit, it is connected with red power with positive voltage, actuator going down When not in the upper limit, it is connected with yellow power with positive voltage, actuator going up When not in the lower limit, it is connected...

 Open the catalog to page 8
JIECANG Linear Actuator JC35L28-9

Communication protocol development Professional customization Intelligent Control of Bluetooth better choices Wireless Communication Latest Weighing System Disclaimer and Exclusion of Liability The user must determine the suitability of JIECANG products under specific conditions. JIECANG is committed to providing the latest product information. However, as JIECANG’ s product are constantly improving, it is possible to make changes to JIECANG’ s product without prior notice. Therefore, JIECANG cannot guarantee the correctness and authenticity of the product information. Although JIECANG will do...

 Open the catalog to page 9

All Jiecang Linear Motion catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.