JC35DN Linear Actuator Application field - Medical Line & Technical Line preferably in hospital beds, operating tables and other technical applications The actuator JC35DN combines compact design and high power in a solution fit for use in medical and technical demanding applications. A comprehensive testing program is behind the durable performance of this solid and high-quality actuator JC35DN. ·Thrust up to 6000N ·Rated up to max. IP66 ·Stroke length 50-600mm ·Hall signal optional ·Max. load speed: 25mm/s Features And Options Dynamic Load In Push(N): Dynamic Load In Pull(N): Colour: Protection Class: Stroke Length: Installation Dimension: Noise Level: Optional: Limit Switch: Weight: Static Bending Moment: Approval: 8000 | 6000 | 4000 | 3000 | 2000 | 1500 | 1000 | 750 | 500 4000 | 2000 | 1000 | 750 | 500 Gray / Black Max. IP66 8000N: 50-200mm (in steps of 4mm) 6000N: 50-250mm (in steps of 4mm) 4000N: 50-400mm (in steps of 4mm) 3000N: 50-400mm (in steps of 4mm) 2000N: 50-600mm (in steps of 4mm) | 1500N: 50-600mm (in steps of 4mm) | 1000N: 50-600mm (in steps of 4mm) | 750N: 50-600mm (in steps of 4mm) | 500N: 50-600mm (in steps of 4mm) L=S+175(S<400) L=S+195(S≥400) ≤55dB (environmental noise ≤40dB) regular version ≤60dB (environmental noise ≤40dB) fast version Hall Sensor, Only Push, Reed Switch Built-in (electronic) About 1.5kg (different stroke length and installation dimensions with different weight) Lateral load is not allowed IEC60601-1: 2012 EN 60601-1: 2006+A12:2014 ANSI/AAMI ES60601-1: 2005/(R)2012 and A1: 2012 C1:2009/(R)2012 and A2
Open the catalog to page 1O JIECANGUsage Duty Cycle: 10%, max. continuous work for 2min. and 18 min. off Supporting Control Box: Matching with JIECANG control box Relative Humidity: 20% to 90% at 30C, non-condensing Front clevis A, end clevis D
Open the catalog to page 2O JIECANG ront clevis D, end clevis D
Open the catalog to page 3O JIECANGTechnical Specifications (Standard Value) Input Current at full load (A) Remarks: It can achieve better self-locking ability with Jiecang control box; The above data is the standard value of the test data (inspection specification) at room temperature of 25°C.
Open the catalog to page 4O JIECANGTechnical Specifications (Standard Value) Input Current at full load (A) Remarks: It can achieve better self-locking ability with Jiecang control box; The above data is the standard value of the test data (inspection specification) at room temperature of 25°C.
Open the catalog to page 5O JIECANGDiagram of relationship between stroke length and load ^ 7 Characteristic Curve Typical speed Min. speed Typical current Max. current Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Load capacity(N) Load capacity(N)
Open the catalog to page 6O JIECANG Typical speed - Typical current - Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Load capacity(N) Load capacity(N)
Open the catalog to page 7O JIECANG Typical speed - Typical current - Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Load capacity(N) Load capacity(N)
Open the catalog to page 8Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) O JIECANG Typical speed - Typical current -
Open the catalog to page 9Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Load capacity(N) Load capacity(N) 1500N O JIECANG Typical speed - Typical current -
Open the catalog to page 10O JIECANG Typical speed - Typical current - Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Load capacity(N)
Open the catalog to page 11O JIECANG Typical speed - Typical current - Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Load capacity(N) Load capacity(N) Load capacity(N) Load capacity(N) Load capacity(N) Load capacity(N) Load capacity(N) Load capacity(N)
Open the catalog to page 12O JIECANG Typical speed - Typical current - Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Load capacity(N) Load capacity(N) Load capacity(N) Load capacity(N)
Open the catalog to page 13O JIECANG Typical speed - Typical current - Load capacity(N) Load capacity(N) Load capacity(N)
Open the catalog to page 14O JIECANGOrdering KeyTake JC35DN06324150/325HGDZD2022D0 as an example Model
Open the catalog to page 15O JIECANGOrdering Details Dimensions of clevis
Open the catalog to page 16Dimensions of JC35DN with control box JCB35Q installing with JC35DN
Open the catalog to page 17O JIECANGMotor cable4 Pin Din connector (standard) Supporting control boxes: JCB35Q / JCB35T / JCB35R / JCB35R1 /JCB35S
Open the catalog to page 18O JIECANGStrictly abiding by medical safety certifications Passed EMC tests. To ensure our products pass all kinds of tests domestic or abroad. Communication protocol development Aiming at different applications, develop more extensive functions for control system. Professional customization Powerful R&D strength, fully satisfy customers’ needs. Development cycle is about 10 days, seizing more market opportunities Intelligent Control of Bluetooth Mobile phone as the remote, applying in home care. Market pioneer, Jiecang provides better choices Controllers adopt high-frequency wireless system....