Overview: The JC35DN Linear Actuator is designed for medical and technically demanding applications, offering a compact design with high power. It is suitable for use in hospital beds, operating tables, and other technical applications.
Specifications:
  • Thrust capacity up to 6000N.
  • Rated protection class up to IP66.
  • Stroke length ranges from 50mm to 600mm.
  • Optional Hall signal.
  • Maximum load speed of 25mm/s.
  • Dynamic load in push: up to 8000N; in pull: up to 4000N.
  • Noise level: ≤55dB for regular version, ≤60dB for fast version.
  • Weight approximately 1.5kg, varying with stroke length and installation dimensions.
  • Static bending moment: lateral load is not allowed.
Standards and Approvals:
  • IEC60601-1: 2012
  • EN 60601-1: 2006+A12:2014
  • ANSI/AAMI ES60601-1: 2005/(R)2012 and A1: 2012
Installation and Usage:
  • Installation dimensions: L=S+175(S<400), L=S+195(S≥400).
  • Duty cycle: 10%, max. continuous work for 2min. and 18 min. off.
  • Operating temperature: +5℃ to +40℃; reserve temperature: -10℃ to +50℃.
  • Relative humidity: 20% to 90% at 30℃, non-condensing.
  • Atmospheric pressure: 700 to 1060hPa.
Technical Specifications:
  • Input voltage: 24VDC.
  • Spindle pitch: 4mm to 7.5mm.
  • Mechanical self-locking capability enhanced with Jiecang control box.
  • Speed at no load/full load varies with load capacity.
Ordering Information: The ordering key includes options for color, motor direction, stroke length, installation dimensions, load capacity, brake options, speed, and connector type.
Disclaimer: JIECANG reserves the right to make changes to product specifications without prior notice and cannot guarantee delivery capacity for specific products. All sales are subject to JIECANG's sales and delivery standard clauses.
See more

Catalog excerpts

JIECANG Linear Actuator JC35DN-1

JC35DN Linear Actuator Application field - Medical Line & Technical Line preferably in hospital beds, operating tables and other technical applications The actuator JC35DN combines compact design and high power in a solution fit for use in medical and technical demanding applications. A comprehensive testing program is behind the durable performance of this solid and high-quality actuator JC35DN. ·Thrust up to 6000N ·Rated up to max. IP66 ·Stroke length 50-600mm ·Hall signal optional ·Max. load speed: 25mm/s Features And Options Dynamic Load In Push(N): Dynamic Load In Pull(N): Colour: Protection Class: Stroke Length: Installation Dimension: Noise Level: Optional: Limit Switch: Weight: Static Bending Moment: Approval: 8000 | 6000 | 4000 | 3000 | 2000 | 1500 | 1000 | 750 | 500 4000 | 2000 | 1000 | 750 | 500 Gray / Black Max. IP66 8000N: 50-200mm (in steps of 4mm) 6000N: 50-250mm (in steps of 4mm) 4000N: 50-400mm (in steps of 4mm) 3000N: 50-400mm (in steps of 4mm) 2000N: 50-600mm (in steps of 4mm) | 1500N: 50-600mm (in steps of 4mm) | 1000N: 50-600mm (in steps of 4mm) | 750N: 50-600mm (in steps of 4mm) | 500N: 50-600mm (in steps of 4mm) L=S+175(S<400) L=S+195(S≥400) ≤55dB (environmental noise ≤40dB) regular version ≤60dB (environmental noise ≤40dB) fast version Hall Sensor, Only Push, Reed Switch Built-in (electronic) About 1.5kg (different stroke length and installation dimensions with different weight) Lateral load is not allowed IEC60601-1: 2012 EN 60601-1: 2006+A12:2014 ANSI/AAMI ES60601-1: 2005/(R)2012 and A1: 2012 C1:2009/(R)2012 and A2

 Open the catalog to page 1
JIECANG Linear Actuator JC35DN-2

O JIECANGUsage Duty Cycle: 10%, max. continuous work for 2min. and 18 min. off Supporting Control Box: Matching with JIECANG control box Relative Humidity: 20% to 90% at 30C, non-condensing Front clevis A, end clevis D

 Open the catalog to page 2
JIECANG Linear Actuator JC35DN-3

O JIECANG ront clevis D, end clevis D

 Open the catalog to page 3
JIECANG Linear Actuator JC35DN-4

O JIECANGTechnical Specifications (Standard Value) Input Current at full load (A) Remarks: It can achieve better self-locking ability with Jiecang control box; The above data is the standard value of the test data (inspection specification) at room temperature of 25°C.

 Open the catalog to page 4
JIECANG Linear Actuator JC35DN-5

O JIECANGTechnical Specifications (Standard Value) Input Current at full load (A) Remarks: It can achieve better self-locking ability with Jiecang control box; The above data is the standard value of the test data (inspection specification) at room temperature of 25°C.

 Open the catalog to page 5
JIECANG Linear Actuator JC35DN-6

O JIECANGDiagram of relationship between stroke length and load ^ 7 Characteristic Curve Typical speed Min. speed Typical current Max. current Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Load capacity(N) Load capacity(N)

 Open the catalog to page 6
JIECANG Linear Actuator JC35DN-7

O JIECANG Typical speed - Typical current - Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Load capacity(N) Load capacity(N)

 Open the catalog to page 7
JIECANG Linear Actuator JC35DN-8

O JIECANG Typical speed - Typical current - Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Load capacity(N) Load capacity(N)

 Open the catalog to page 8
JIECANG Linear Actuator JC35DN-9

Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) O JIECANG Typical speed - Typical current -

 Open the catalog to page 9
JIECANG Linear Actuator JC35DN-10

Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Load capacity(N) Load capacity(N) 1500N O JIECANG Typical speed - Typical current -

 Open the catalog to page 10
JIECANG Linear Actuator JC35DN-11

O JIECANG Typical speed - Typical current - Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Load capacity(N)

 Open the catalog to page 11
JIECANG Linear Actuator JC35DN-12

O JIECANG Typical speed - Typical current - Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Load capacity(N) Load capacity(N) Load capacity(N) Load capacity(N) Load capacity(N) Load capacity(N) Load capacity(N) Load capacity(N)

 Open the catalog to page 12
JIECANG Linear Actuator JC35DN-13

O JIECANG Typical speed - Typical current - Current (A) or Speed (mm/s) Current (A) or Speed (mm/s) Load capacity(N) Load capacity(N) Load capacity(N) Load capacity(N)

 Open the catalog to page 13
JIECANG Linear Actuator JC35DN-14

O JIECANG Typical speed - Typical current - Load capacity(N) Load capacity(N) Load capacity(N)

 Open the catalog to page 14
JIECANG Linear Actuator JC35DN-15

O JIECANGOrdering KeyTake JC35DN06324150/325HGDZD2022D0 as an example Model

 Open the catalog to page 15
JIECANG Linear Actuator JC35DN-16

O JIECANGOrdering Details Dimensions of clevis

 Open the catalog to page 16
JIECANG Linear Actuator JC35DN-17

Dimensions of JC35DN with control box JCB35Q installing with JC35DN

 Open the catalog to page 17
JIECANG Linear Actuator JC35DN-18

O JIECANGMotor cable4 Pin Din connector (standard) Supporting control boxes: JCB35Q / JCB35T / JCB35R / JCB35R1 /JCB35S

 Open the catalog to page 18
JIECANG Linear Actuator JC35DN-19

O JIECANGStrictly abiding by medical safety certifications Passed EMC tests. To ensure our products pass all kinds of tests domestic or abroad. Communication protocol development Aiming at different applications, develop more extensive functions for control system. Professional customization Powerful R&D strength, fully satisfy customers’ needs. Development cycle is about 10 days, seizing more market opportunities Intelligent Control of Bluetooth Mobile phone as the remote, applying in home care. Market pioneer, Jiecang provides better choices Controllers adopt high-frequency wireless system....