1. Catalogs
  2. Jiangsu YLD Water Processing Equipment Co., Ltd.
  3. Constant pressure water supplying device

Constant pressure water supplying device

Constant pressure water supplying device

Constant pressure water supplying device

Product catalog summary
Introduction
The document discusses the challenges of scaling in central air conditioning condenser and evaporator pipes, which can lead to reduced heat exchange efficiency and increased energy consumption. It highlights the importance of regular water treatment during the cooling period to prevent scale formation. The use of a condenser online cleaning device is emphasized as an effective solution to maintain clean cooling pipes, prolong their lifespan, and enhance economic benefits.

Working Principle
The cleaning device operates by injecting rubber balls into the condenser, which scrub off fouling from the heat exchanging tubes. These balls are collected and recirculated, forming a continuous cleaning cycle. The process is controlled by a Siemens PLC intelligent control box, ensuring automatic online cleaning and optimal heat exchange efficiency.

Components
  • Ball Dispenser/Injection Machine: This device manages the distribution and operation of rubber balls, ensuring they have adequate space for movement and cleaning.
  • Ball Collector Device: Essential for the continuous recovery and reuse of rubber balls, made from corrosion-resistant stainless steel.
  • Rubber Balls: Various types are used, including standard peeling rubber balls, general rubber balls, and diamond sand balls, each suited for different cleaning needs and pipe materials.

Characteristics of Rubber Ball Cleaning Device
The device offers significant energy savings, automatic online cleaning, and increased service life of compressors and pipelines. It ensures high heat transfer efficiency and is environmentally friendly due to its physical treatment process.

Technical Parameters
The document provides a table listing different models of the cleaning device, detailing their inlet/outlet sizes and dimensions for both the main machine and ball collector.
See more

Catalog excerpts

Constant pressure water supplying device-1

Condenser rubber ball cleaning device Introduction For central air conditioning condenser and evaporator pipe, it is easy to be scaling. The normal daily water treatment should be processed during the summer time cooling water supply period, otherwise, the condenser will run in the high degree hardness water system, inorganic salts dissolved in circulating cooling water system will be crystallized and precipitated out ,scales will be formed on the tubes of condenser and it will reduce heat exchange efficiency. As hard scale increased, energy-consumption will be increased, when the knot hard mass scale is 1mm in thickness, the energy cost will be increased by 6%~10%; as water form scales with dirt, sediment, and rot colonization dirt, also the bacteria, and algae, microbial and its secretion form bio stick mud, it will attach in the pipes of condensation device, seriously it will caused pipeline block. Dirt and mud will effect hot exchange efficiency, higher energy cost will lead to high power voltage, seriously it cause super pressure voltage till down time. All these factors affect the normal operation of the heat exchanger. Condenser online cleaning equipment is the best effectively cleaning equipment for central air conditioning chiller cooling pipes .The performance of this device will influence cleaning and heat exchange efficiency of the main engine cooling pipe. Central air-conditioning market has been expanded in recent years, condenser online cleaning device is widely used for cleaning central air conditioning chiller, with continuous working without lowering the load ,it can clean online at any time, which keeps the cooling pipes to be clean, prolong the life of cooling pipes, reduce labor intensity and increase economic benefits. Condenser online cleaning device is an indispensable device for safe and economic operation in central air condition system. Working principle The rubber balls are sent into the condenser by injection machine,rubber ball relies on the high flow rate of cooling water to scrub off fouling from heat exchanging copper tube of condenser. The ball collector will collect the rubber balls at outlet cooling water, the balls will come back to the collectingdriving device through collection pipe, which will form a cleaning cycle.

 Open the catalog to page 1
Constant pressure water supplying device-2

Cleaning frequency is set by Siemens PLC intelligent control box to realize automatic on-line cleaning and keep the internal wall of condenser be clean, which will also realize the highest heat exchange efficiency and highest cooling effect on cooling water machine. Balls through pump condenser ball cleaning device PLC balls not through pump condenser ball cleaning device Ball Dispenser/injection machine Automatic cleaning ball serving device is used in the rubber ball, driving the ball and observe rubber ball operation equipment. It is mainly composed of a casing, top cover, the ball collecting...

 Open the catalog to page 2
Constant pressure water supplying device-3

Ball collector device The ball collecting device is the key process of condenser rubber ball cleaning in one of the equipments. In order to maintain the rubber ball cleaning of continuous condensing tube, will Everfount into the rubber ball cleaning system, the cleaning of the cooling pipe rubber ball timely recovery, again for the purpose of cleaning the ball collecting device is used to. Scattered all collected in cooling water of rubber ball, for repeated use, so the ball collecting device of ball collecting rate is very important. Net ball collecting device adopts 304 stainless steel materials,...

 Open the catalog to page 3
Constant pressure water supplying device-4

Characteristics of rubber ball cleaning device 1, The lowest energy saving of 10%, up to 40%, the ball rate of up to 99%. 2, Less than a year can be recycled one-time investment costs 3, Automatic online cleaning, ensure the condenser without any fouling and corrosion. 4, Avoid and eliminate the abnormal high pressure state when the air conditioner is running 5, Increase the service life of compressor and pipeline 6, To ensure that the condenser at the highest heat transfer efficiency 7, Complete physical treatment, chemical processing costs, protect the environment 8,The whole process of PLC...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.