Elecnova BCM201
6Pages

{{requestButtons}}

Catalog excerpts

Elecnova BCM201 - 1

AC Precision Distribution Monitoring Unit

Open the catalog to page 1
Elecnova BCM201 - 2

DC Precision Distribution Monitoring Unit Components Name Main module (Incoming line monitoring module) BCM201-M1 BCM201-M2 Slave module (Feeder monitoring module) BCM201-S BCM201-M1 can measure the electrical parameters of one DC circuit, and BCM201-M2 can measure the electrical parameters of two DC circuits. The electrical parameters include voltage, current, power, energy, demand, extreme value, temperature, etc. The main modules are equipped with two RS485 communication ports, one Ethernet port(optional), four digital inputs and two relay outputs; they are also equipped with two bus...

Open the catalog to page 2
Elecnova BCM201 - 3

Parameters Parameters U/1:0.5 class. P/Active energy: 1 class(Hall sensor included) Rated value Power consumption sO.IVA (each phase) Withstand voltage Two RS485 ports, Modbus-RTU protocol One RJ45 interface, Modbus-TCP protocol (optional) Power supply Working range Installation dimension

Open the catalog to page 3
Elecnova BCM201 - 4

Parameters Parameters Signal input U/1:0.5 class. PI Active energy. 1 class (with Hall sensor) Rated value DC48V, DC240V, DC336V (optional) Incoming line monitoring module BCM101-M1 (Single incoming line) BCM101-M2 (Double incoming lines) Digital Type Signal input Feeder monitoring module BCM201 -S(DC-48V system) BCM202-S(DC240V/DC336V system) <0.1 30 digital inputs,judging the opening and closing of circuit breaker through voltage Digital input status value, if voltage>40V,circuit breaker closes, if voltage<30V,circuit breaker opens. Busbar interface Installation dimension

Open the catalog to page 4
Elecnova BCM201 - 5

AC Precision Distribution Monitoring Unit Parameters Display unit BCM201-HMI Parameter Specification Circuits 60 circuits,wet contact input Input voltage range DC24V + 2V

Open the catalog to page 5
Elecnova BCM201 - 6

AC Precision Distribution Monitoring Unit BCM201-S can measure 30 single-phase loops and extend the BCM201-S module when it is over 30.When you need to measure other switch information, you can extend the BCM101-K module.BCM201-S and BCM101-K cannot be crossed between two incoming lines, such as 72 (36+36), and 4 BCM201-S and 2 BCM101-K are required. The return number is 52 (26+26), and two BCM201-S and BCM101-K modules are required.

Open the catalog to page 6