Catalog excerpts
AC Precision Distribution Monitoring Unit Elccnova JIANGSU SFERE ELECTRIC CO.,LTD.
Open the catalog to page 1AC Precision Distribution Monitoring Unit Overview BCM101 AC precision distribution monitoring unit is used to monitor electrical parameters of array cabinet, to measure electrical parameters such as voltage, current, energy and harmonics of inlet and outlet branches and to monitor the switch status of all circuit breakers in data center. BCM101 is equipped with trip alarm function and over current alarm function which can be set in every output circuit by two-level users so as to prevent potential power failure. BCM101 is configured with 7-inch human-machine interface and Ethernet...
Open the catalog to page 2AC Precision Distribution Monitoring Unit
Open the catalog to page 3AC Precision Distribution Monitoring Unit Parameters Signal input Parameter Specification U. I: 0.2 class. P, Q, PF: 0.5 class Accuracy Active energy: 1 class: Reactive energy: 2 class Rated value Single phase AC 220V Continuous: 1.2Un. Instantaneous: 2Un/1min £0.1 VA (each phase) >1.6MO External current transformer with max. current 100A Continuous: 1.2ln. Instantaneous: 10ln/5s S0.2VA (each phase) Impedance £20mfi 30 digital inputs, judging the opening and closing of circuit breaker through Digital input status voltage value. If voltage > 120V, circuit breaker closes; if...
Open the catalog to page 4AC Precision Distribution Monitoring Unit Parameter Specification Input voltage range_AC/DC: 8,0y~270,V_ Output power $ 20W Installation dimension L*W*H(mm):36*90>'63.5, DIN35mm rail mounted
Open the catalog to page 5AC Precision Distribution Monitoring Unit Typical wiring Double incoming line system Double independent incoming lines system, take branch circuits 120 in total for example. Monitoring units are installed in power distribution cabinet to realize switch status monitoring of incoming line circuit, feeder circuit and feeder branch circuits. BCM101-S can measure 30 single phase circuits. If the number of circuits is bigger than 30, please extend to two BCM101-S modules; if the number of circuits is bigger than 60, please extend to 3 BCM101-S modules. If user needs other information of switches,...
Open the catalog to page 6All Jiangsu Sfere Electric Co. catalogs and technical brochures
-
Energy Storage System
17 Pages
-
ECO-B20FT5015LP
2 Pages
-
ECO-B20FT3404WS
2 Pages
-
ECO-E100WX
2 Pages
-
ECO-B372LS
2 Pages
-
ECO-E233LS
2 Pages
-
ECO-E215WS
2 Pages
-
APF
9 Pages
-
1946 series
3 Pages
-
LNF 53,56,58 series
3 Pages
-
PD194Z-9HY
2 Pages
-
Sfere720 series
4 Pages
-
Elecnova Sfere720B
2 Pages
-
Elecnova BCM201
6 Pages