video corpo

APF

APF

APF

Product catalog summary
Background
The document discusses the impact of nonlinear loads on power systems, highlighting the significant proportion of harmonic distortion in the grid. This distortion increases line loss and interferes with the operation of protection and automation devices.

Introduction to SFR-APF
The SFR-APF active power filter is designed to improve power quality by dynamically filtering harmonics and compensating reactive power in real-time. It addresses the limitations of conventional methods like passive harmonic filters and is applicable in various industries such as power, metallurgy, and petroleum.

Benefits of Harmonic Control
  • Cost Reduction: Extends equipment lifespan and reduces investment costs.
  • Stable Production: Ensures normal equipment operation and stable production.
  • Energy Efficiency: Reduces energy consumption and supports environmental protection.
  • Purifying Power Grid: Decreases harmonic pollution and may earn rewards from power supply departments.

Main Features
  • Dynamic Tracking Compensation: Offers active filtering, reactive power compensation, and unbalanced current compensation.
  • Excellent Filtering Performance: Capable of filtering up to the 51st harmonic with a rate greater than 97%.
  • Flexible Application Scheme: Modular design allows for easy expansion and various installation options.
  • Protection for Equipment and System: Includes internal and external fault protection, automatic derating, and resonance avoidance.
  • Human-Machine Interaction: Features LCD touch screens for clear graphical display of power quality improvements.

Technical Parameters
  • Model Description: Includes various models with different capacities and configurations.
  • Performance Indicators: High efficiency, fast response time, and adjustable filtering parameters.
  • Communications and Monitoring: Supports RS485 and Modbus-RTU for monitoring.
  • Environment Requirements: Operates within specific temperature, humidity, and altitude ranges.
  • Standards Compliance: Complies with several EU directives and standards.

Worldwide Projects
The document lists several projects where the SFR-APF has been implemented, showcasing its application in diverse settings such as hydropower stations and commercial complexes.
See more

Catalog excerpts

APF-2

BRIEF INTRODUCTION SFR-APF active power filter is a new type of power quality improvement production for dynamically filtering harmonics and compensating As great amount of the nonlinear load was applied in the power system,the harmonic distortion accounts a big proportion of the grid. It increased the line loss of the power supply and interfered the running of the protection devices of the power substation and automation devices of the industrial control system. reactive power. It can filtering and compensate harmonic (variable in orders and frequency) and dynamic reactive power in real time. It...

 Open the catalog to page 2
APF-3

The APF acquires the current signal of the load by the CT, separating the harmonic by the intelligent FFT(Fast Fourier Transform) by the DSP than send to the internal IGBT by the PWM signal. The APF will generate generate the compensation current with the same value but opposite phase as the system harmonic in order to achieve the real-time dynamic filtering function.

 Open the catalog to page 3
APF-4

MAIN FEATURES SFR-APF is applied to realize dynamic tracking compensation and on-demand allocation of active filtering, reactive power compensation and unbalanced current compensation. EXCELLENT PROTECTION FOR EQUIPMENT AND SYSTEM Device internal fault protection Device external electrical fault protection Automatic derating if the working environment exceeds the limits FLEXIBLE APPLICATION SCHEME Support current limiting through software and hardware Modular design, easy to expand, up to 8 modules can be connected in parallel. Resonance avoidance Plug-in frame or wall-mounted installation, adapt...

 Open the catalog to page 4
APF-5

TECHNICAL PARAMETER MODEL DESCRIPTION SFR-APF Grid Wall-mounted Rack-mounted Mounting Type Floor type System Rated Input Power Grid Frequency Parallel Operation Overall Efficiency Power Grid Structure Circuit Topology Performance Indicators Rated Capacity Compensation Mode Harmonic, reactive power, unbalance Filtering Range Filtering Order Filtering Degree Reaction Time Response Time Target Power Factor Control Algorithm TABLE OF RAPID MODEL SELECTION FFT, Intelligent FFT and instantaneous reactive power Switching Frequency Cooling Mode Noise Level Communications and Monitoring Capabilities RS485...

 Open the catalog to page 5
APF-6

WORLDWIDE PROJECTS Xinjiang, Hami Hydropower Station ELECTRIC APPLICATION SOLUTION EXPERT ACTIVE POWER FILTER

 Open the catalog to page 6
APF-7

Dongfeng Honda Auto Parts Co. LTD

 Open the catalog to page 7
APF-8

Zhuhai, Yanheng Land Commercial Complex

 Open the catalog to page 8
APF-9

Beijing Kehua Zhongsheng Network Cloud Computing Engineering Company Project JCET, jiangsu, china

 Open the catalog to page 9

All Jiangsu Sfere Electric Co.,Ltd. catalogs and technical brochures

  1. ECO-E100WX

    2  Pages

  2. ECO-B372LS

    2  Pages

  3. ECO-E233LS

    2  Pages

  4. ECO-E215WS

    2  Pages

  5. 1946 series

    3  Pages

  6. PD194Z-9HY

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.