Think Without Boundary GTAKE PRODUCT CATALOG PRODUCT CATALOG ii
Open the catalog to page 1ABOUT GTAKE Think Without Boundary serving VARIABLE FREQUENCY DRIVE markets Every day, we apply our knowledge, resources, and efforts to create systems and products that perform under incredible demands. We listen, think, and address the challenges our customers face, and consequently deliver solutions that are a prime part of the technology that is changing the world. We deliver lasting contributions to motor control and clean energy systems, solutions and products, seeking pathes to sustainable development for the world. We integrate leading-edge technologies into industrial variable...
Open the catalog to page 2serving WIND POWER AND SOLAR POWER markets Gtake all investors, employees are dedicated, inventive, and hard-working. They applied those traits, along with outstanding craftsmanship, service, and integrity when they founded what was to become Gtake in 2009. Those very qualities remain the basis of our business philosophy today. Gtake’s leadership in motion control, energy steering and optimized solutions is built on that foundation of strategic vision, quality performance, and its core value - customer first. We build on our proven successes with technologies that redefine the way our...
Open the catalog to page 3SOCIAL RESPONSIBILITY Gtake creates a prejudice-free environment that cultivates talents, propels self-development, and provides meaningful work. Through our employees and technology, our goal is to provide the highest value and quality systems, products, and services that contribute to our customers’ satisfaction and success. We believe Gtake does more than provides jobs in the districts in which we operate. The promotion and maintenance of occupational health and safety is the primary responsibility of Gtake management. Human and financial resources in line with the importance attached to...
Open the catalog to page 4GTAKE ACDRIVE GTAKEEV DRIVE 67 Certificaions
Open the catalog to page 5HELP YOUR SYSTEMS stay efficient, stable, and energy saving They have the fundamental features of Gtake drives, enabling our customers to have easy, efficient, stable control of any application powered by an AC motor. The application would be a fan, pump, convey, compressor, central air-conditioning, centrifuge, CNC, hoist, crane, drawbench, etc. State-of-the-art technology Major energy saving F"- ra P\) R^HS compliant components Macro program operation Overall protection A ball mill, crane, elevator such heavy duties request bigger start torque than normal duties, users are abl*to Every...
Open the catalog to page 6FEATURES Reliable Ambient temperature 50° C without derating Thickened conformal coating Optimized cooling system Less need for cooling or oversizing Resistant to harsh surroundings Lower temperature rise GK500 Mini AC Drive The GK500 series adopting V/Hz control technology are the most economical drives at Gtake which are applicable to general purpose applications. POWER RATINGS COMPATIBILITY Small in Size, Powerful in Performance 1 x 220 - 240V 3x 220 - 240V 3x 380 - 480V Asynch motor control applicable CONTROL TECHNOLOGY V/Hz control GK500 adopt book-type frames to save mounting space....
Open the catalog to page 7Promoted WHz GK500 adopting promoted V/Hz control technique make the start torque reach 180% of the rated at 0.5Hz. Mains supply (L1/L, L2, L3/N) Supply voltage Strong adaptability to temperature Derating is not required for GK500 at ambient temperature up to 50‘C. True Power Factor (A) 0.92 nominal at rated load Displacement Power Factor (cos <t>) near unity (>0.98) Switching on input supply L1/L, L2.L3/N Maximum 2 times/min. Output data (U/T1, WT2, W/T3) Output voltage 0-100% of supply voltage Switching on output Unlimited Note: 150% current can be provided for 1 minute,...
Open the catalog to page 8Digital output MODEL INFORMATION Rate 4800/9600/19200/38400/57600Formats RTU, ASCII Programmable digital/pulse outputs 1Voltage level 0-24VCurrent level 0-50mA Model'1 Relay output Remote control panel Power Rating (kW) Rated Output Current (Amps) Rated Input Current (Amps)'2 Applicable Dimensions Programmable relay outputs 1 Maximum cable length 5m BASIC CONNECTION NOTE *1: A(/B), A tells triphase input current, B tells single phase input current. '2:200V drives are applicable to triphase 200V and single-phase 200V. Paired Cable Shielded Cable
Open the catalog to page 9GK600 General Purpose AC Drive Multifunctional and Versatile FEATURES Reliable Ambient temperature 45° C without derating Thickened conformal coating Optimized cooling system Less need for cooling or oversizing Resistant to harsh surroundings Lower temperature rise The GK600 series are the drives that cover general purpose applications when they are requiring V/Hz and speed sensor-less vector control. Asynch motor control applicable CONTROL TECHNOLOGY V/Hz control SVC1 SVC2 User-friendly Parameter copy Detachable control panel One platform numerous versions Save time for Commissioning Easy...
Open the catalog to page 10Hot pluggable and detachable control pannel Quite conveninet for users to implement remote control via a cable connection, and the settings are easily transferred via the control pannel to another drive or from a PC to a drive with Gtake Drive Monitoring Software Big start torque Tailored with optimal algorithm, GK600 drives are able to output up to 180% of rated torque at 0.5Hz of V/Hz mode, SVC1 mode, and output 180% at 0.25Hz of SVC2 mode. Strong overload capability One platform millions of version is the basic design concept of GK600. Numerous options are available and can be mounted...
Open the catalog to page 11Quick dynamic response Torque response time of GK600 drives is as short as 10ms at SVC1 or SVC2 mode. Mains supply (R/L1, S/L2, T/L3) Supply voltage Cycle-By-Cycle current limit The GK600 drives are equipped with the function of cycle-by-cycle current limit. The drive knows how to adjust its output frequency and current suitably to avoid trip when there is a saltation at the load. True Power Factor (A) 0.92 nominal at rated load Displacement Power Factor (cos<f>) near unity (>0.98) Switching on input supply R/L1, S/L2.T/L3 Maximum 2 times/min. Short dead time between forward and...
Open the catalog to page 12All Jiangsu Gtake Electric Co. catalogs and technical brochures
-
Battery Simulator for Test Bench
16 Pages
-
2-Wheeler Motor Controller
12 Pages
-
GK1000
4 Pages
-
GK600
6 Pages
-
GK800
5 Pages
-
SLR01
6 Pages
-
GS100M
2 Pages
-
GK 600E
4 Pages
-
GK500
2 Pages
-
Solar Pump Drive
3 Pages
-
GSM100M
2 Pages
-
KTZ X50FBB01
4 Pages