Catalog excerpts
Click to return to table of contents Connection Diagram of Motor and Driver……………..……………………..5
Open the catalog to page 2Features / Product Characteristic This closed-loop speed controller is designed with the latest type IGBT and MOS power devices. It takes advantage of DC brushless motor’s Hall signal to double frequency for closed-loop speed control. PID control links with the speed controller. The control system is stable and reliable, especially at low speed, it always can reach the maximum torque, The speed control range is from 150 to 20000rpm. 1. Features PID speed, current double loop regulator. 20KHz chopper frequency. Electrical stop to ensure the quick action. Over load ratio larger than...
Open the catalog to page 3Terminal Connection Hall signal A input Hall signal B input Hall signal C input Hall signal power line Terminal Name CW/CCW terminal Stop/Start terminal Analog signal input terminal +5V power output terminal Signal ground
Open the catalog to page 4Connection Diagram of motor and driver / Dimension 4. Connection Diagram of Motor and Driver
Open the catalog to page 5Speed Adjustment Method External input adjustment : Connect the terminals of the external potentiometer to the GND and +5v terminal, connect the regulator terminal to SV, then you can adjust the speed by using an external potentiometer. It also can achieve speed adjust through other control units (Such as PLC, SCM, etc.) input analog voltage to SV. The acceptance of SV is DC 0V~+5V, and the corresponding motor rotation speed is 0 to rated speed. Motor Operation / Stop Control (EN) You can control the brushless motor to run or stop by controlling the terminal “EN” and “GND” connection. The...
Open the catalog to page 6If the driver control adopts communication mode, it is directly connected to the upper computer through RS485 and controlled through RS485 communication command. Transmission mode RTU, validation mode CRC, CRC start word FFFFH. Data mode: 8-bit asynchronous serial, 1 stop bit, invalid bit check, and fixed communication rate of 9600bps. Specific communication instructions and sample routines can be obtained from DINGS’. 7. Use of Product 1. Ensure that motor line, hall line and power line connected correctly, Motor and driver will be damaged if lines connected incorrectly. 2. When adjusting...
Open the catalog to page 7Maximum speed in analog First byte : start torque Second byte : start speed without sense start 03 First byte : accelerate time Second byte : decelerate time First byte : max. current Second byte : Type 90h is hexadec 15 is sensor, 16 is sensorless Communication speed setting Brake force First byte : site address Second byte : reserved Real speed First byte : bus voltage second byte : bus current First byte: reserved Second: reserved First byte : fault status Second byte : reserved 00: No AlarmSW4 Bit3: 01: Motor Blocked (shaft stuck) 02: Overload 03: Motor hall fault page│8
Open the catalog to page 8(hall wire disconnected or damaged) 04: Low supply voltage 08: High supply voltage 20: Large instantaneous motor current (sudden motor load increase or motor phase circuit short) 1C Site address 8000H-8017H Read-write register Site address 8018H-801FH Read-only register Other address is illegal 8000: first byte: EN: when NW=0, 0: external EN low level effective when NW=1, 0: EN ineffective FR: when NW=0, 0: external FR low level effective when NW=1, 0: FR ineffective 1: external FR high level effective BK: when NW=0, 0: external BK low level effective when NW=1, 0: BK ineffective 1:...
Open the catalog to page 9International Customer Person in Charge : Daniel Jang daniel@dingsmotion.com Building 1#, 355 Longjin Road, Changzhou Economic Development Zone, Jiangsu, China +86-519-85177826, 85177827 North America Customer Person in Charge : Nicolas Ha sales@dingsmotionusa.com 335 Cochrane Circle Morgan Hill, CA 95037 +1-408-612-4970 China Customer Person in Charge : info@dingsmotion.com Building 1#, 355 Longjin Road, Economic Development Zone, Jiangsu, China www.dingsmotion.com Changzhou Economic Development Zone, Jiangsu, China +86-519-85177826, 85177827 It is prohibited to copyright or replication of...
Open the catalog to page 11All Jiangsu DINGS' Intelligent Control Technology Co. catalogs and technical brochures
-
Simple Brochure
36 Pages
-
General Catalog
288 Pages
-
DS-CLS9-FRS4-01_Technical Manual
34 Pages
-
DS-CLS9-FRS4_Technical Manual
26 Pages
-
DS-OLS2-FPD_Technical Manual
19 Pages
-
DS-OLS22_FPD_Technical Manual
16 Pages
-
DS-OLS4-FPD_Technical Manual
23 Pages
-
DS-OLS8-FPD_Technical Manual
16 Pages
-
DS-OLS7-FRS4_Technical Manual
30 Pages
-
DS-OLS8-FRS4_Technical Manual
32 Pages
-
DS-OLS10-FSC_Technical Manual
12 Pages
-
DS-CLS9-FCAO_Technical Manual
62 Pages
-
DS-CLS9-FETC_Technical Manual
19 Pages
-
DS-CLS9-FETC-2A_Technical Manual
43 Pages
-
DS-CLS9-FETC-2I_Technical Manual
43 Pages
-
DS-OL42-ICAO_Technical Manual
57 Pages
-
DS-OLBS4-FRS4_Technical Manual
11 Pages
-
DS-OLBS8-FRS4_Technical Manual
15 Pages
-
DS-BVM-FETC-FCAO_Hardware Manual
15 Pages
-
DINGS Servo Studio Manual
58 Pages
-
DS-BVS-BVM-Series_Reference Manual
181 Pages
-
DS-BVS-FETC-FCAO_Hardware Manual
18 Pages