Group: Jewell Instruments
Catalog excerpts
C2 C–Frame Solenoid High-Performance, Cost-Effective C-Frame Solenoids Jewell Instruments delivers proven levels of performance and high reliability with its new MAGNETEC family of open-frame solenoids. Their coil systems are terminated with .025 inch square pins to accommodate commercially available mating terminals and connectors. The use of terminals inserted in a coil bobbin flange is far more cost effective than electrically terminating an open-frame solenoid with long leads. The materials used in the coil system are capable of withstanding a total temperature of 130°C (ambient plus heat rise)! Benefits High Power Efficiencies — Very magnetically-efficient open-frame design optimizes power consumption. Proven Performance — Built for dependability and extremely reliable under rugged conditions. Cost-Effective Design — Jewell Instruments’ experience in high-volume production results in a design that is less labor-intensive to manufacture. Typical Applications Include: • ATM machines • Copiers • Gambling machines • Tape drives • Automotive • Disk drives • Printers • Circuit breakers • Bill changers • Fax machines • Scanners Solenoid Solutions That Fit Your Unique Needs For over 25 years, Jewell Instruments has provided businesses with highquality, standard and custom solenoids. We also offer next-level assembly support in addition to designing and manufacturing electronic modules that interface with solenoids and other electromechanical devices. Superb product design sets us apart from the competition with our engineering expertise covering mechanical, electro-mechanical, magnetics and electronics. Add that to our broad applications understanding and our decades of solenoid sales experience. The result is a solid reputation for quality, reliability, innovative solutions, unmatched customer service and very flexible production scheduling. Top: C206 Push-Type Bottom: C204 Pull-Type Technical Information Insulation Material Class B Rating (standard) Maximum Operating Temperature 130˚C (266˚F) Dielectric Strength 50 Volts and Under: 500 VRMS Over 50 Volts: 1,000 VRMS Standard Voltages and Duty Cycles Voltage, DC – 6, 12, 24 Duty Cycles – 10%, 25%, 100% Weight Plunger – 0.05 oz. Solenoid Total – 0.17 oz. Plunger Cone Angle 60 Degrees (standard) Others Available Termination .025 Square, Phosphor Bronze Pins, .30 Long
Open the catalog to page 1Pull Type Voltage Push Type Voltage Part Number Part Number Part Number 25.7 OHMS 102.9 OHMS 411.4 OHMS 9.73 OHMS 38.9 OHMS 155.7 OHMS 3.67 OHMS 14.7 OHMS 58.8 OHMS Part Number Part Number Part Number 25.7 OHMS 102.9 OHMS 411.4 OHMS 9.73 OHMS 38.9 OHMS 155.7 OHMS 3.67 OHMS 14.7 OHMS 58.8 OHMS sales@jewellinstruments.com • www.jewellinstruments.com • 800 227-5955 850 Perimeter Road • Manchester, NH 03103
Open the catalog to page 2All Jewell Instruments catalogs and technical brochures
-
RMIW-D Series
2 Pages
-
RMIW-L Series
2 Pages
-
RMIW-S Series
2 Pages
-
JDI-100/200
9 Pages
-
ASXC Angular Accelerometer
2 Pages
-
ECV eCompass Datasheet
10 Pages
-
Little Dipper Datasheet
6 Pages
-
ECOMPASS – ECS SERIES
7 Pages
-
eCompass Selector Guide
1 Pages
-
ECG eCompass Datasheet
7 Pages
-
ECL eCompass Datasheet
7 Pages
-
ECS eCompass Datasheet
7 Pages
-
A801 Tuff Tilt Datasheet
2 Pages
-
JMA-100/200/300-S Datasheet
3 Pages
-
JMA-100/200/300-D Datasheet
3 Pages
-
QFA-180
2 Pages
-
DXA 100/200-R Data Sheet
4 Pages
-
DXA 100/200 Data Sheet
4 Pages
-
LCF-2330 Datasheet
4 Pages
-
LCF-2000
2 Pages
-
Tuff Tilt 420 Datasheet
3 Pages
-
D711 Tiltmeter Datasheet
2 Pages
-
D701 Tiltmeter Datasheet
2 Pages
-
MD900-T Clinometer Datasheet
2 Pages
-
QFA-125
2 Pages
-
DynamicCSG Jewell
2 Pages
-
DynamicASG Jewell
2 Pages
-
LSR Datasheet
2 Pages
-
LCF 196 Inclinometer
2 Pages
-
Sensors Catalog
12 Pages
-
Partnership Manufacturing
2 Pages
-
Analog MEMS Comparison Chart
1 Pages
-
LCF-100/101 Datasheet
2 Pages
-
Round Emerald Series (RMI)
2 Pages
-
Square Emerald Series (SMI)
2 Pages
-
LCF-300 Series
4 Pages
-
LCF-3500 Series
2 Pages
-
LCF-2530 Series
2 Pages
-
LSB Series
2 Pages
-
LSMP Series
2 Pages
-
LCF-200 Series
2 Pages
-
ASB Series
2 Pages
-
Lily Datasheet
2 Pages
-
LCF-300-L Inclinometer
4 Pages
-
701-2(4X) Platform Tiltmeter
2 Pages
-
LCF-300-S Inclinometer
4 Pages
-
LCF-300-D Inclinometer
4 Pages
-
RMI-D Datasheet
2 Pages
-
SMI-L Inclinometer Datasheet
2 Pages
-
SMI-D Inclinometer Datasheet
2 Pages
-
LSB Accelerometer Datasheet
2 Pages
-
LSO Inclinometer Datasheet
2 Pages
-
A901-2 Clinometer Datasheet
2 Pages
-
A900 Clinometer Datasheet
2 Pages
-
A701-2 Tiltmeter Datasheet
2 Pages
-
Rail Sensor Selector Guide
2 Pages
-
LSOX-S, 0-5 VDC Output
5 Pages
-
LSOX-D, +/-5 VDC Output
5 Pages
-
T24 Interposer Tubular
2 Pages
-
T12 Interposer Tubular
2 Pages
-
C4 C-Frame
2 Pages
-
DXA-100/200-R
2 Pages
-
• RMIW-S
2 Pages
-
SMI-S, 0-5V Output
2 Pages
-
LCF-2310 Series Inclinometer
2 Pages
-
LCI Series
2 Pages
-
QFM-180
2 Pages
-
LCF 2000/3000 Inclinometer
2 Pages
-
Concrete Strain Gage
2 Pages
-
LCA-100 Series
2 Pages
-
ASMP Series
2 Pages
-
LSOC-8 Series Data Sheet
2 Pages
-
LSO Series Data Sheet
2 Pages
-
LSM Data Sheet
2 Pages
-
LSB-R Data Sheet
2 Pages
-
LCF-501-R Data Sheet
2 Pages
-
LCF-501 Data Sheet
2 Pages
-
LCF-3000 Data Sheet
2 Pages
-
LCF-200 Data Sheet
2 Pages
-
LCF-196 Data Sheet
2 Pages
-
LCA-165-R Data Sheet
2 Pages
-
LCA-165 Data Sheet
2 Pages
-
ASM Series Data Sheet
2 Pages
-
ASB Data Sheets
2 Pages