83056_ Series_ 72 Series+Bio CPVH AUG17
8Pages

{{requestButtons}}

Catalog excerpts

83056_ Series_ 72 Series+Bio CPVH AUG17 - 1

72 Series Spectrophotometers The 72 series spectrophotometers are ideal for applications in education, life science and routine testing in clinical, veterinary, pharmaceutical and QC laboratories.

Open the catalog to page 1
83056_ Series_ 72 Series+Bio CPVH AUG17 - 2

Introducing the 72 Series The 72 series spectrophotometers are the first scanning spectrophotometers in the Jenway range to leverage diode array technology to produce exceptionally fast results. The range includes three models: model 7200 covers a wavelength range of 335 to 800nm with a spectral bandwidth of 7nm and model 7205 covers a wavelength range of 198 to 800nm with a spectral bandwidth of 5nm. There is also a third model dedicated to life science analysis, the 7205Bio which covers a wavelength range of 198 to 800nm with a spectral bandwidth of 3nm. The 72 series spectrophotometers...

Open the catalog to page 2
83056_ Series_ 72 Series+Bio CPVH AUG17 - 3

Visible, UV/visible and life science models Scanning diode array technology Color touchscreen navigation Small footprint and lightweight Fast scan speed English, French, German, Spanish and Italian language options Multiple USB ports for data storage and printer Extensive range of accessories available Diode Array Technology The benefits of diode array technology include very fast scanning with the ability to scan the entire wavelength range of 198 to 800nm in less than 6 seconds (7205/7205Bio), which is ideal for fast chemical reactions and denaturing materials. Traditional...

Open the catalog to page 3
83056_ Series_ 72 Series+Bio CPVH AUG17 - 4

The Nucleic Acids measurement mode can be used to quantify the concentration and purity of dsDNA, ssDNA, RNA and oligonucleotides using wavelengths recorded at 260, 280 and 230nm, with an optional correction at 320nm. The concentration is calculated along with the corresponding purity ratios 260/280nm and 260/230nm. At the touch of a button it is easy to visually check the purity of the nucleic acids. This is done by identifying unusual peak ^ levels in the purity scan between 200 and 350nm. This is especially useful for RNA samples where impurities maybe present at 230nm, but cannot be...

Open the catalog to page 4
83056_ Series_ 72 Series+Bio CPVH AUG17 - 5

Product Code Description 83056-01 7200 visible scanning spectrophotometer, fitted with 10x10mm cuvette holder, and supplied with a universal power supply and an instruction manual. 83056-02 7205 UV/visible scanning spectrophotometer, fitted with 10x10mm cuvette holder, and supplied with a universal power supply and an instruction manual. 83056-04 Genova Bio/7205 Bio UVvisible scanning spectrophotometer, fitted with micro-cuvette holder, and supplied with a universal power supply and an instruction manual. JSample Chamber The instruments have been cleverly designed to incorporate...

Open the catalog to page 5
83056_ Series_ 72 Series+Bio CPVH AUG17 - 6

Accessories The 72 series spectrophotometers have been designed to be compatible with the extensive range of accessories already available from Jenway. These include a test tube holder, adjustable path length (10 to 100mm) cuvette holder and a microcuvette holder. All of the accessories are easy to interchange using the ergonomic thumb screw. For applications where the temperature of the sample needs to be controlled there is a heated cuvette accessory. The heated cuvette holder accepts 10x10mm cuvettes and enables 2.5ml of sample to be heated to 37°C in 30 minutes. When this accessory is...

Open the catalog to page 6
83056_ Series_ 72 Series+Bio CPVH AUG17 - 7

Test Tube Holder - (83070-43) For larger sample volumes there is a test tube holder which can hold test tubes with diameters of 13, 16 or 24mm. Adjustable Path Length Cuvette Holder - (83056-80) Where cuvettes greater than 10mm are required there is an adjustable path length cuvette holder which can accept cuvettes with a path length from 10 to 100mm. Micro-cuvette Holders - (83056-82) & (83056-06) For small sample volumes down to 50µl Jenway offer a micro-cuvette holder which is ideal for use with micro-cuvettes. Select the accessory depending on your cuvettes. Heated Cuvette Holder -...

Open the catalog to page 7
83056_ Series_ 72 Series+Bio CPVH AUG17 - 8

7200 7205/Bio Wavelength Range Accuracy Repeatability Spectral bandwidth Photometries Transmittance Absorbance Accuracy Stability (A) +/- 0.005A/h at 0.04A and 546nm after 60 min warm-up +/- 0.005A/h at 0.04A and 546nm after 60 min warm-up Stray Light at 340nm, %T <1 %T according to ANSI/ASTM E387-72 Concentration Standard Optical Density +/- 2500 Blank with a single standard or factor +/- 1000 +/- 1000 +/- 2500 Blank with a single standard or factor +/- 1000 +/- 1000 Calibration Curve fit algorithms Kinetics Measurement Time Number of...

Open the catalog to page 8

All Jenway catalogs and technical brochures

  1. PFP7

    1 Pages

  2. 7415 Nano

    4 Pages

  3. Genova Bio

    3 Pages

  4. traycell

    1 Pages

  5. 74 Series

    2 Pages

  6. Genova Nano

    4 Pages

  7. Fluorimeters

    8 Pages

Archived catalogs