Material Description:
Polytetrafluorethylene (PTFE) sheets are cut into gasket shapes. PTFE is prone to deformation and creep relaxation under high temperature and pressure over time. This can be mitigated by adding fillers like glass or carbon.
Applications:
  • Suitable for use with chemicals, solvents, caustics, and acids, except for free fluorine, alkali metals, alkali-metal liquid ammonia, and specific organic chemicals.
  • Ideal for fluids where contamination or coloring is not permissible.
  • Service Temperature Range: -100°C to 100°C.
  • Maximum Service Pressure: 0.98 MPa (10 kg/cm²).
Gasket Specifications:
  • Material: PTFE
  • Thickness: 1.5 mm and 3.0 mm
  • Gasket 'm' values: 3.2 for 1.5 mm thickness, 2.5 for 3.0 mm thickness
  • Minimum Design Seating Stress Y: 2.3 kgf/mm² for 1.5 mm thickness, 2.0 kgf/mm² for 3.0 mm thickness
  • Flange Surface: Suitable for L.M&F flange, L.T&G flange
  • Hardness (Shore D): 51
Size:
  • Thickness Range: 1.0 mm to 3.0 mm
  • Maximum Gasket Size: 1500 mm
Typical Physical Properties:
  • Density: 2.15 g/cm³ (JIS K 7137)
  • Tensile Strength: 23.2 MPa (2.37 kgf/mm²)
  • Elongation: 310%
See more

Catalog excerpts

JIC 8305 (PTFE)-1

DESCRIPTION Polytetrafluorethylene (P.T.F.E) sheet is cut into gasket shape. As PTFE Shows deformation and creep relaxation under high temperature and high pressure surroundings for a long time, it is not recommended for these conditions. However, it can be considerably reduced by incorporation of suitable fillers such as glass, carbon, etc. APPLICATION - Chemicals, solvents, caustics and acids except free fluorine, alkali metals, alkali-metal liquid ammonia and specific organic chemicals - Fluids where contamination or coloring is not allowed. - Service Temperature : -100~100℃ - Service Pressure : 0.98 MPa (10 kg/cm²) Max. Min. Design seating stress Y (kgf/mm²) SIZE Thickness (mm) : 1.0 ~ 3.0 Max. Gasket Size (mm) : 1500 Typical Physical Properties Test Method Flange Surface Tensile strength.MPa [kgf/㎟] Elogation[%] Remark For flanges : L.M&F flange, L.T&G