Belt Cooler

Belt Cooler

Belt Cooler

Product catalog summary
Overview: The document describes a cooling system designed for optimal heat transfer and homogeneous cooling, primarily used in fresh-cut, robotics, and steaming applications. The system utilizes a belt cooler with a water spraying mechanism to achieve efficient cooling.
System Description: The cooling system features a raining system where water is sprayed over products via raining plates. The open structure of the transport conveyor allows water to pass through, collected by plates between the belt. Water is guided outside the framework at central points, and sections are removable for cleaning. Water basins with parabolic filters (1,000 micron) are installed next to the belt cooler, facilitating water flow in a counter-flow manner for optimal cooling.
Technical Specifications: The belt cooler is available in various models (HYC 062 to HYC 142) with effective widths ranging from 600 mm to 1,400 mm and lengths from 3,500 mm to 7,500 mm. The system includes a modular, plastic, perforated belt, a scraper for cleaning, and a drive system controlled by an inverter. The frame and piping are made of SS 304 stainless steel, ensuring durability and hygiene.
Control and Options: The system includes a control panel with on/off controls for the belt inverter, pumps, and main water supply valve, along with emergency stops. Optional features include a topside with lids to prevent water splashing and dirt ingress, a full flow system with a single water basin, and a heat exchanger for maintaining low water temperatures.
Additional Information: JBT FTNON offers tailor-made machines, with capacities and dimensions depending on specific product requirements. The equipment complies with international safety and hygiene standards.
See more

Catalog excerpts

Belt Cooler-1

FTNON Belt cooler &JBT In case of this belt cooler, the cooled water is sprayed over the product over the entire surface of the belt cooler. Over the whole effective length a raining system is provided. Water is sprayed over the product by raining plates. As the transport conveyor has an open structure, the water is running through. The water is collected by collecting plates, which are mounted in between the belt. At central points, the water is guided outside the framework. These sections are removable for cleaning. The water basins are installed next to the belt cooler. On top of these water basins, parabolic filters are placed, filtration 1,000 micron. The system has 3 water basins. The bottoms of the water basins are mounted at an angle to transport the water to one side and to reduce the total water volume. This to moderate the running empty of the machine. At the lowest point a drain valve is installed. Due to the high water circulation an optimum heat transfer and a homogeneous cooling down can be reached. Water runs in counter-flow through the system. The chilled water is added at the outfeed section. The water flows over, from one water basin to the other. The overflow is situated at the first water basin. EFFECTIVE LENGTH, APPROX. TOTAL LENGTH, APPROX. FRESH-CUT, ROBOTICS, STEAMING

 Open the catalog to page 1
Belt Cooler-2

Spraying capacity 490 US gallon/h per square foot belt surface (20 m3/h per m2 belt surface) To be calculated for each machine • Cooling water volume • Cooling capacity • Temperature cooling water • Product temperature in • Product temperature out Belt Modular, plastic, perforated Belt cleaning Scraper Pump 3x, SS 304 Drive Drive per belt by means of a motor gearbox combination, controlled by an inverter. Frame The frame is made out of SS 304. Piping is complete with tri-clover clamps for easy removal and proper cleaning. Controls A SS 304 control panel is installed against the frame work. Cabling...

 Open the catalog to page 2

All JBT Corporation catalogs and technical brochures

  1. Static Retort

    8  Pages

  2. Tuna Cooker

    4  Pages

  3. Air Cleaner

    4  Pages

  4. Wahers

    6  Pages

  5. FVPGrow

    4  Pages

  6. SuperCRss™

    4  Pages

  7. Unifiller

    8  Pages

  8. Flash-Cooler

    4  Pages

  9. SteriCompact

    2  Pages

  10. MEDALLION

    4  Pages

  11. FranRica

    2  Pages

  12. BottleTec

    2  Pages

  13. GTRe

    2  Pages

  14. AP60

    2  Pages

  15. GT5eX-Twin

    2  Pages

  16. GT4e

    2  Pages

  17. GTeX-Twin

    2  Pages

  18. GT2e

    2  Pages

  19. GT1e

    2  Pages

  20. GT0e

    2  Pages

  21. GT2sX-Twin

    2  Pages

  22. GT2s

    2  Pages

  23. GT1s

    2  Pages

  24. GT0s

    2  Pages

  25. Pumpideal

    4  Pages

  26. Hot Break

    2  Pages

  27. Cold Break

    2  Pages

  28. Brush Washer

    2  Pages

  29. Crate Washer

    4  Pages

  30. Bin Tipper

    4  Pages

  31. Air Dryer

    4  Pages

Archived catalogs

  1. AV Sealer

    2  Pages

  2. Tuna

    2  Pages

  3. SeamTec

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.