BV Series VANE PUMPS
Open the catalog to page 1FIXED DISPLACEMENT HYDRAULIC VANE PUMPS “BV” SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained in a cartridge unit that can be easily removed for inspection and/or replacement without disconnecting the pump from the circuit, drastically reducing expensive machine down time. The cartridge contains a rotor, vanes and inserts, a cam ring and two covers. During operation the rotor is driven by a splined shaft coupled to the drive unit. As the rotation speed increases, centrifugal forces,...
Open the catalog to page 2General description Fixed displacement vane pump, hydraulically balanced, with capacity determined by the type of cartridge used and the speed of rotation. The pump is available in six versions with capacities from 8 to 55 l/min (from 2 to 14 gpm) at 1200 rpm and 7 bar. Technical characteristcs Cartridge model Geometric displacement Rated capacity Maximum pressure Rated capacity Hydraulic fluids: antiwear high quality mineral oils or fire resistant fluid having same lubrication capacities of the mineral oil. Viscosity range (with mineral oil): from 13 to 860 cSt. (13 to 54 cSt....
Open the catalog to page 4single pump BV01 Main operating data max pressure / hydraulic fluid 200 0 Antiwear industrial hydraulic oil Water glycol Water-in-oil emulsion Peak pres. (0,5 sec.max) max speed / hydraulic fluid (with 0 bar in the intake pipe) Antiwear industrial hydraulic oil Syntetic fire resistant fluid Water glycol Water-in-oil emulsion If the intake pressure is not zero bar, use the graph below to find the percentage correction factor to apply to the maximum speed max speed / intake pipe pressure PSI -2,9 Intake pipe pressure (BAR) % correction factor for the max speed
Open the catalog to page 5single pump BV01 Cartridge V01-02 flow / pressure PSI 725 power / pressure input torque / pressure PSI 0 NM Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR flow / pressure power / pressure input torque / pressure PSI Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR
Open the catalog to page 6single pump BV01 Cartridge V01-08 flow / pressure PSI 0 power / pressure input torque / pressure PSI 0 Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR Cartridge V01-09 flow / pressure PSI 725 power / pressure input torque / pressure PSI Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR
Open the catalog to page 7single pump BV01 Cartridge V01-11 flow / pressure power / pressure input torque / pressure PSI 0 Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR Cartridge V01-12 flow / pressure PSI 0 power / pressure input torque / pressure Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR
Open the catalog to page 8flow / pressure power / pressure input torque / pressure Installation dimensions mm (inches)
Open the catalog to page 9Model code breakdown Pump series Design Pump type Cartridge type Outlet port positions (outlet viewed from cover end) B = Outlet 90° CCW from inlet C = Outlet in line with inlet D = Outlet 90° CW from inlet (omit with standard seals and D = standard seals and double (viewed from shaft end) L = left hand rotaton CCW (omit if CW) 01 = Straight with key (standard) Shaft Options mm (inches) Spline data Spline Involute side fit (ASA B5.15)
Open the catalog to page 10Part No. Type M8020060 primary in NBR M8020065 primary in FPM M8020061 secondary in NBR M8020066 secondary in FPM Shaft seal Parts Type seals + 1 shaft seal NBR seals + 2 shaft seals NBR seals + 1 shaft seal FPM (Viton®) seals + 2 shaft seals FPM (Viton®) left hand right hand Pump rotat. Id. codes of pump components
Open the catalog to page 11General description Fixed displacement vane pump, hydraulically balanced, with capacity determined by the type of cartridge used and the speed of rotation. The pump is available in five versions with capacities from 47 to 79 l/min (from 12 to 21 gpm) at 1200 rpm and 7 bar. Technical characteristcs Cartridge model Geometric displacement Rated capacity Maximum pressure Rated capacity Hydraulic fluids: antiwear high quality mineral oils or fire resistant fluid having same lubrication capacities of the mineral oil. Viscosity range (with mineral oil): from 13 to 860 cSt. (13 to 54 cSt....
Open the catalog to page 12single pump BV02 Main operating data max pressure / hydraulic fluid 2900 0 Antiwear industrial hydraulic oil Syntetic fire resistant fluid Water glycol Water-in-oil emulsion Peak pres. (0,5 sec.max) max speed / hydraulic fluid (with 0 bar in the intake pipe) Antiwear industrial hydraulic oil Syntetic fire resistant fluid Water glycol Water-in-oil emulsion If the intake pressure is not zero bar, use the graph below to find the percentage correction factor to apply to the maximum speed max speed / intake pipe pressure PSI -2,9 Intake pipe pressure (BAR) % correction factor for the max speed
Open the catalog to page 13single pump BV02 Cartridge V02-12 flow / pressure power / pressure input torque / pressure Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR Cartridge V02-14 flow / pressure PSI 725 power / pressure input torque / pressure PSI Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR
Open the catalog to page 14single pump BV02 Cartridge V02-17 flow / pressure power / pressure input torque / pressure PSI Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR Cartridge V02-19 flow / pressure PSI 725 power / pressure input torque / pressure Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR
Open the catalog to page 15flow / pressure power / pressure input torque / pressure Installation dimensions mm (inches)
Open the catalog to page 16single pump BV02 Model code breakdown Mounting (omit if not required) Pump series Seals (omit with standard seals and one shaft-seal in NBR) V = seals and shaft-seal in FPM (Viton®) D = standard seals and double shaft-seals in NBR F = seals and double shaft-seals in FPM (Viton®) Rotation Outlet port positions (viewed from shaft end) L = left hand rotaton CCW (omit if CW) (outlet viewed from cover end) A = Outlet opposite end B = Outlet 90° CCW from inlet C = Outlet in line with inlet D = Outlet 90° CW from inlet Shaft end options 01 = Straight with key (standard), 11 = Splined 86 = Heavy...
Open the catalog to page 17All Jbj Techniques Limited catalogs and technical brochures
-
PUMP DRIVE COMPONENTS
61 Pages
-
Shaft locking devices
92 Pages
-
HIGH/LOW, 2 STAGE / GEAR PUMPS
14 Pages
-
S-Flex Couplings
32 Pages
-
Hydraulic Gear Motors
56 Pages
-
Planetary Gearboxes
48 Pages
-
Yoke Drive Flywheel Couplings
14 Pages
-
Bearing Supported Stub Shafts
12 Pages
-
This is what we do
1 Pages
-
HQ series vane pumps
48 Pages
-
Pneumatic Starters
6 Pages
-
Coolers & Heat Exchangers
78 Pages
-
Hydraulic power take-off units
28 Pages
-
Gear pump summary
12 Pages
-
FLUID POWER ACCESSORIES
66 Pages
-
F15 Ferra Series
20 Pages
-
KT Pressure Switch
8 Pages
-
Rotary Gear Flow Dividers
16 Pages
-
W Series
8 Pages
-
GPA Series
18 Pages
-
jbj Coolers Summary
2 Pages
-
An excellence in engineering
1 Pages
-
PIPE FLANGES PORT FLANGES
102 Pages
-
TANKS / RESERVOIRS
22 Pages
-
PRESSURE INTENSIFIERS
22 Pages
-
SCREW PUMPS
50 Pages
-
HAZARDOUS AREAS SCREW PUMPS
24 Pages
-
SCREW PUMP RELIEF VALVES
14 Pages
-
BQ Series VANE PUMPS
108 Pages
-
TQ and TV Series VANE PUMPS
36 Pages
-
HQ Series VANE PUMPS
38 Pages
-
B1 and B2 Series VANE PUMPS
10 Pages
-
All steel gear couplings
26 Pages
-
This is jbj Techniques!
28 Pages
-
Vane pumps
10 Pages
-
Fluid power accessories
54 Pages
-
Fluid reservoirs
22 Pages
-
pressure intensifiers
22 Pages
-
screw pumps
50 Pages
-
API 676 compliant screw pumps
24 Pages
-
Petrol engine adaptors
6 Pages
-
Torque limiting couplings
20 Pages
-
Torsional couplings
48 Pages
-
jbj PRODUCT SUMMARY
6 Pages
-
Equipment for Hazardous Areas
44 Pages
-
PDC
58 Pages