BQ Series VANE PUMPS
Open the catalog to page 1FIXED DISPLACEMENT HYDRAULIC VANE PUMPS “BQ” SERIES Versatility, power, compactness and low running costs are the main characteristics of B&C vane pumps. All the components subject to wear are contained in a cartridge unit that can be easily removed for inspection and/or replacement without disconnecting the pump from the circuit, drastically reducing expensive machine down time. The cartridge contains a rotor, vanes and inserts, a cam ring, two flexible plates and two covers. During operation the rotor is driven by a splined shaft coupled to the drive unit. As the rotation speed increases, centrifugal...
Open the catalog to page 2General description Fixed displacement vane pump, hydraulically balanced, with capacity determined by the type of cartridge used and the speed of rotation. The pump is available in seven versions with capacities from 8 to 55 l/min (from 2 to 14 gpm) at 1200 rpm and 7 bar. Technical characteristics Cartridge model Geometric displacement Rated capacity Maximum pressure Rated capacity Hydraulic fluids: mineral oils, phosphate ester based fluids. Viscosity range (with mineral oil): from 13 to 860 cSt. (13 to 54 cSt. recommended). Filtration: for the inlet - 149 micron abs., for the return line -...
Open the catalog to page 4single pump BQ01 Main operating data max pressure / hydraulic fluid 0 Antiwear industrial hydraulic oil Syntetic fire resistant fluid max pres. peak pres. (0,5 sec.max) max speed / hydraulic fluid (with 0 bar in the intake pipe) 3000 2500 Antiwear industrial hydraulic oil If the intake pressure is not zero bar, use the graph below to find the percentage correction factor to apply to the maximum speed max speed / intake pipe pressure PSI -2,9 % correction factor for the max speed Intake pipe pressure (BAR)
Open the catalog to page 5single pump BQ01 Cartridge A01-02 flow / pressure PSI 725 power / pressure input torque / pressure PSI 0 NM Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR flow / pressure power / pressure input torque / pressure PSI Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR
Open the catalog to page 6single pump BQ01 Cartridge A01-08 flow / pressure PSI 0 input torque / pressure PSI 0 Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR Cartridge A01-09 flow / pressure PSI 725 power / pressure input torque / pressure PSI 0 Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR
Open the catalog to page 7single pump BQ01 Cartridge A01-11 flow / pressure power / pressure input torque / pressure PSI 0 Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR Cartridge A01-12 flow / pressure PSI 0 power / pressure input torque / pressure Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR
Open the catalog to page 8flow / pressure power / pressure input torque / pressure Installation dimensions mm (inches)
Open the catalog to page 9single pump BQ01 Model code breakdown Mounting (omit if not required) Pump series Seals (omit with standard seals and one shaft-seal in NBR) V = seals and shaft-seal in FPM (Viton®) D = standard seals and double shaft-seals in NBR F = seals and double shaft-seals in FPM (Viton®) Pump type Rotation Outlet port positions (viewed from shaft end) L = left hand rotation CCW (omit if CW) (outlet viewed from cover end) A = Outlet opposite end B = Outlet 90° CCW from inlet C = Outlet in line with inlet D = Outlet 90° CW from inlet Shaft end options 01 = Straight with key (standard) 11 = Splined 90 =...
Open the catalog to page 10Type primary NBR primary FPM secondary NBR secondary FPM Shaft seal Parts Type seals + 1 shaft seal NBR seals + 2 shaft seals NBR seals + 1 shaft seal FPM (Viton®) seals + 2 shaft seals FPM (Viton®) left hand right hand Pump Rotat. Id. codes of pump components
Open the catalog to page 11General description Fixed displacement vane pump, hydraulically balanced, with capacity determined by the type of cartridge used and the speed of rotation. The pump is available in five versions with capacities from 47 to 79 l/min (from 12 to 21 gpm) at 1200 rpm and 7 bar. Technical characteristics Cartridge model Geometric displacement Rated capacity Maximum pressure Rated capacity Hydraulic fluids: mineral oils, phosphate ester based fluids. Viscosity range (with mineral oil): from 13 to 860 cSt. (13 to 54 cSt. recommended). Filtration: for the inlet - 149 micron abs., for the return line -...
Open the catalog to page 12single pump BQ02 Main operating data max pressure / hydraulic fluid 0 Antiwear industrial hydraulic oil Syntetic fire resistant fluid peack pres. (0,5 sec.max) max speed / hydraulic fluid (with 0 bar in the intake pipe) 3000 2500 Antiwear industrial hydraulic oil If the intake pressure is not zero bar, use the graph below to find the percentage correction factor to apply to the maximum speed max speed / intake pipe pressure PSI -2,9 % correction factor for the max speed intake pipe pressure (BAR)
Open the catalog to page 13single pump BQ02 Cartridge A02-12 flow / pressure power / pressure input torque / pressure PSI Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR Cartridge A02-14 flow / pressure PSI 725 input torque / pressure PSI Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR
Open the catalog to page 14single pump BQ02 Cartridge A02-17 flow / pressure power / pressure input torque / pressure PSI Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR Cartridge A02-19 flow / pressure power / pressure input torque / pressure PSI Oil viscosity: 25 c.St.(10W) Temperature: 45°C Inlet pressure: 0 BAR
Open the catalog to page 15flow / pressure power / pressure input torque / pressure Installation dimensions mm (inches)
Open the catalog to page 16single pump BQ02 Model code breakdown Mounting (omit if not required) Pump series Seals (omit with standard seals and one shaft-seal in NBR) V = seals and shaft-seal in FPM (Viton®) D = standard seals and double shaft-seals in NBR F = seals and double shaft-seas in FPM (Viton®) Rotation (viewed from shaft end) L = left hand rotation CCW (omit if CW) Outlet port positions (outlet viewed from cover end) A = Outlet opposite end B = Outlet 90° CCW from inlet C = Outlet in line with inlet D = Outlet 90° CW from inlet Shaft end options 01 = Straight with key (standard), 11 = Splined 86 = Heavy duty...
Open the catalog to page 1761 Pages
92 Pages
14 Pages
32 Pages
56 Pages
48 Pages
14 Pages
12 Pages
1 Page
48 Pages
6 Pages
78 Pages
28 Pages
12 Pages
66 Pages
20 Pages
8 Pages
16 Pages
8 Pages
18 Pages
2 Pages
102 Pages
22 Pages
22 Pages
50 Pages
24 Pages
14 Pages
94 Pages
36 Pages
38 Pages
10 Pages
26 Pages
28 Pages
10 Pages
54 Pages
22 Pages
22 Pages
50 Pages
24 Pages
6 Pages
20 Pages
48 Pages
6 Pages
44 Pages
58 Pages