1. Catalogs
  2. JAKSA SOLENOID VALVES
  3. 2/2 AIR OPERATED VALVES

2/2 AIR OPERATED VALVES

2/2 AIR OPERATED VALVES

2/2 AIR OPERATED VALVES

Product catalog summary
Overview: This document provides technical specifications and features of air-operated valves manufactured by JAKŠA d.o.o., including piston valves, high-pressure valves, and diaphragm valves.
1. Piston Valves (Sizes 1/2” - 2”):
  • Controlled by compressed air acting on a piston.
  • Shut by spring force; opens when pilot pressure is applied.
  • Pilot fluid is exhausted through a pipe vent.
2. Air-Operated High Pressure Valves (Max 400 bar):
  • Technical Data:
    • Ports: 1” (DN25), 6/4” (DN40), 2” (DN50).
    • Differential pressure: 0 - 6 bar.
    • Pilot pressure: Max 8 bar.
    • Body and internal parts: Brass, stainless steel.
    • Seals: NBR, EPDM.
    • Fluid temperature: -10°C to +75°C; Ambient temperature: Max +55°C.
    • Viscosity: Max 21 mm²/s.
    • Response time: 10 - 20 ms.
    • Voltage options: 230, 115, 48, 24 V AC; 24, 12 V DC.
    • Duty cycle: Continuous (ED100%).
    • Cycling rate: 10 - 100 cycles/min.
    • Electrical protection: IP65 (with plug to ISO 4400).
    • Explosion-proof solenoids available.
3. Diaphragm Valves (Sizes 1” - 2”):
  • Controlled by pilot fluid (air, water) acting on a diaphragm.
  • Held open by spring force; closes when pilot fluid is applied.
  • Opens when coil is energized and pilot fluid is shut off.
  • Required pilot pressure: 1 bar over main fluid pressure, not exceeding 8 bar.
See more

Catalog excerpts

2/2 AIR OPERATED VALVES-1

2/2 AIR OPERATED VALVES 1/2” - 2” 1. PISTON VALVES, SIZES 1/2” - 2” FEATURES: • Valve is controlled by compressed air acting on piston in the cylinder. We recommend using JAKSA 3-way control valve for pilot fluid shut-off. Various pneumatic control devices can also be used, however. • Valve is shut by the spring force. • When pilot pressure is applied (e.g. by activating the 3-way control valve) the valve opens. When pilot fluid is shut off the valve also shuts. Pilot fluid is exhausted through pipe vent. • Required pilot pressure depends on main fluid pressure, but in must not exceed 10 bar. 2. AIR-OPERATED HIGH PRESSURE VALVES - max 400 bar FEATURES: • Valve is controlled by compressed air acting on piston in the cylinder. • Valve is shut by the spring force. • When pilot pressure is applied the valve opens. When pilot fluid is shut off the valve also shuts. Pilot fluid is exhausted through pipe vent.

 Open the catalog to page 1
2/2 AIR OPERATED VALVES-2

3. DIAPHRAGM VALVES, SIZES 1” - 2” FEATURES: • Valve is controlled by pilot fluid (air, water) acting on the diaphragm which separates it from the main fluid. • In its basic position, the valve is held open by means of spring force. • When pilot fluid is applied the valve closes. Valve opens when the coil is energised and shuts off the pilot fluid. Pilot fluid is exhausted through pipe vent. • Equired pilot pressure is 1 bar over the main fluid pressure, however, it must not exceed 8 bar. TECHNICAL DATA: • Ports: - 1” (DN25) - 6/4” (DN40) - 2” (DN50) • Differential pressure: 0 - 6 bar • Pilot...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.