Overview: The document provides technical specifications and usage guidelines for clamping elements, specifically the MCA-S and MCA-T series clamping nuts. These are designed for simple and manual operation with a handle, featuring fast infeed motion due to automatic changeover.
Specifications:
  • Clamping nuts are available with either a star handle (MCA-S) or a T-handle (MCA-T).
  • Length dimensions conform to DIN ISO 2768 mH standards.
  • Threaded bolt property class should be at least Q 10.9 for sizes up to M 16, and Q 12.9 for larger sizes, unless the maximum static load is reduced.
  • Two grooves on the housing circumference allow for optical control of the screw-in depth, matching tmin and tmax.
  • Material: Heat-treated steel, nitro carburized; cover plate made of high tensile aluminum.
Technical Data:
  • Nominal clamping force ranges from 40 kN to 120 kN depending on the model.
  • Thread sizes include M 10, M 12, M 16, and M 20.
  • Maximum static load varies with thread size, with a maximum of 120 kN.
  • Screw-in depth ranges from 16 mm to 24 mm.
  • Approximate weight is 1.0 kg.
  • Operating temperature range is -30°C to +90°C.
Application Example: The MCA-T clamping nut is used for the adjustment of a test bench sliding table.
See more

Catalog excerpts

Datasheet MCA-S / MCA-T-1

• Clamping Elements Anlri.bstecMk • simple & manual operation with handle • fast infeed motion due to automatic changeover clamping nut MCA-S clamping nut MCA-Twith star handle with T-handle material: heat treated steel - nitro carburized cover plate: high tensile aluminum Technical data and dimensions [mm]: length dimensions according to DIN ISO 2768 mH max. allowed temperature range: -30°C up to +90°C Property class of threaded bolt should be at least Q 10.9. Sizes of thread larger than M 16 should use a property class of Q 12.9, or the max. static load must be reduced. For optical control of actual screw-in depth of the T-bolt, two grooves are cut into the housing circumference matching tmin and tmax. When laying out the actual screw-in depth of the threaded bolt, the necessary stroke must be considered i.e. the max. specified screw-in depth must be reduced by at least the amount of the stroke. MCA-T-clamping nut for adjustment of test bench sliding table Ordering example: MCA-S - M 16 / MCA-T - M 20

 Open the catalog to page 1

All JAKOB Antriebstechnik GmbH catalogs and technical brochures

  1. MCF-VA

    2  Pages

  2. Datasheet KG

    1  Page

  3. Datasheet KP

    1  Page

  4. Datasheet KM

    1  Page

  5. Datasheet KR

    1  Page

  6. Datasheet KE

    1  Page

  7. Datasheet KXL

    2  Pages

  8. Datasheet SC

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.